详细说明:ATI Axia 80 Ethernet版 说明书,主要用于设置ATI Net FT传感器。Manual. F/ Sensor. Ethernet Axia
Document #9610-05-Ethernet axia-07
Note
Please read the manual before calling customer service, and have the following
information available
1. Serial number(e.g, FTO1234)
2. Transducer model(e. g, Axia, ctc)
3. Calibration(e.g, US-15-50, SI-65-6, etc.)
4. Accurate and complete description of the question or problem
For the status code: refer to section 4 8Status Code
5. Computer and software information(operating system, PC type, drivers, application
software, and other relevant information about the configuration
Be near the FiT system when calling(if possible)
Please contact an ATI representative for assistance, if needed
Sale, Service and Information about ati products
ATI Industrial automation
103 1 Goodworth drive
Apex, NC 27539 USA
Tel:+1.919.772.0115
Fax:+1.919.7728259
Application Engineering
Tel:+1.919772.0115, Extension511
Fax:+1919.772.8259
E-mail:ftsupport(ati-ia.com
PnnadePark1031GoodworthDrive.apex,Nc27539.tel:+1919.772.0115.fax:+1919.772.8259.www.ati-ia.com
3
Manual. F/ Sensor. Ethernet Axia
Document #9610-05-Ethernet Axia-07
Statement of Compliance
Order Number
12470285
Report Number. R12470285-EMC Page 2 of 64
Model Number: 9105-NET-Axia80 and 9105-RS485-Axia80
Client name
ATI Industrial Automation
Issued:2018-09-14
Test Report Details
Tests Performed By.
UL Verification Services
12 Laboratory Dr, RTP, NC 27709, USA
Tests Performed For
ATI Industrial Automation
1031 Goodworth Dr
Apex, NC 27539, USA
Issue date
2018-0914
Model Number.
9105-NET-Axia80 and 9105-RS485-Axia80
Sample Serial Number.
Non-serialized
Product standards
EN61326.1
Testing Start Date
2018-0905
Date Testing Complete
2018-0907
overall Results:
Compliant
UL LLC reports apply only to the specific samples tested under stated test conditions. a samples tested were in good operating condition
throughout the entire test prog am. It is the manufacturers responsibility to assure that additional production units of this model are manufactured
with identical electrical and mechanical components. UL LLC shal have no liabi ty for any deductions, inferences or general zations drawn by the
client or others tom UL LLC issued reports. This report must not be used by the client to clam product certification, approval. or endorsement by
NVLAP. NIST, or any agency of the U.s. Govemment.
This report may contain test results that are not covered by the NVLAP or A2LA accreditation. The scope of accreditation is mited to the specfic
tests that are listed on the NvLAP and or A2LA websites referenced at the end of this report
UL LLC I 12 Laboratory Dr I Reseach Trangle Park, NC 2/70e USAI.: 919 540-14001 Rev No 1.0
EMC Report 2012-87-EM-F0042
PnnadePark1031GoodworthDrive.apex,Nc27539.tel:+1919.772.0115.fax:+1919.772.8259.www.ati-ia.com
Manual. F/T Sensor Ethernet Axia
Document #9610-05-Ethernet Axia-O7
Table of contents
Foreword,…,n
Statement of Compliance .........
249
Glossary
1. Safety
1.1 Explanation of Notifications
1.2 General Safety Guidelines.……,…,…
日m
1.3 Safety Precautions
12
2. Product overview…
13
21 Overview of axia models
n14
3. nstallation
15
3.1 nterface Plates…15
3.2 Routing the cable
17
3.3 Installing the Sensor to the robot..............,.,…………,…20
3.4 Removing the sensor from the robot ......................................................................................21
3.5 Pin Assignment for the ethernet and Power Connection.m.....a.....anaaa. 22
3.51 Pin Assignment:6- pin male M8ZC22 Sensor connector…………….22
3.5.2 Pin Assignment: 8-Pin Male M12 ZC28 Connector......
3.53 Pin Assignment for Cable P/N9105CzC28-U-RJ45S-X…………………………23
3.5.3.1 Branch 1. Unterminated End for power connection ........................................23
3.5.3.2 Branch 2. RJ45 Connection for ethernet
23
3.6 Accuracy Check Procedure.
24
4. Operation
26
4.1 Sensor environment
26
4.2 LED Outputs.
4.2.1 Self-Test LED Sequence
26
4.2.2 L/A LED
26
4.2.3D| AG LED.…
:.:::.
27
4.2.4 Sensor status LED
27
4.3 Sample Rate.…,,…,…
27
4.3.1 Sample Rate Versus Data Rate
27
44 Converting Counts Per Force/Torque to F「 Values...….….…………27
4.5 Low-Pass Filter
PinnaePark·1031Goodworthdrive·Apex,NO27539·e:+19197720115·Fax+1919728259·www.ati-a.com
Manual. F/T Sensor Ethernet Axia
Document #9610-05-Ethernet Axia-O7
4. 6 Bias
31
4.7 Tool Transformation
…31
4.7.1 Avoid Overloading the Sensor During Tool Transformation
33
4.7.2 Example of Tool Transformation Functionality Through Telnet
33
4.7.3 EXample of Tool Transformation Functionality Through CGI
4.7.4 EXample of Tool Transformation Functionality Through TCP
34
4.8 Status code
4.8.1 Status Code: Sensing Range Exceeded
35
4.8.2 How to Interpret Hexadecimal Output for the status Code
37
4.9 Diagnostic Monitoring……………38
5. Connecting Through Ethernet…,,…,,…
39
5.1 IP Address Configuration for Ethernet
39
52 Connecting To the atI Webpages Using a Windows Computer………,,,…,……,40
5.3 Finding the Ethernet Axia Sensor on a Network
43
6. Configuring the Sensor with the Ethernet Axia Web Pages
45
61 Welcome Page( index. htm)……....….….….….…………45
6.2 Snapshot Page( rundata htn)……,,,,.......,,,…,……,246
6.3 Demo Page( demo. htm)…................……….47
6.4 ADC Settings Page(setting. htm)
47
65 Thresholding Page( moncon htm)…..……………….248
66 F/T Configurations Page( config. htm)……
51
6.7 Communication Page( comm . ht)……,,,,,,,,
52
68 System Information Page(manuf ht)…......….……….……………53
69 ATI Web Site Menu item,,…,,……,,,…
…53
7. Java Demo Application…,,.,,,…,…,…,…,…,…,…,…,…,…,…,……….54
71 Starting the Demo……,,,……,……,………54
7.2 Data Display with the demo
56
7. 3 Collecting Data with the Demo.
………56
7. 4 Demo csv file format,mww 58
7.5 The Errors Field Display of the Demo..........
60
7.6 Developing a Customized Java Application.
8. Console Interface Through Telnet
61
8.1 Setting-Up Communications
61
8.2 Console commands
62
8.3 Secondary Commands for the Query"c"or"s"Command
64
8.3.1 Examples of Secondary Commands(Specifiers
65
84 Console“CAL"|“SET” Command fields and values…,.....,,,,66
Pinnacepark:1031G0rthdrive·Apex,NO27539·e:+191920115·5a+1919,728259·www,ati-|a.com
Manual. F/T Sensor Ethernet Axia
Document #9610-05-Ethernet Axia-O7
9. Common Gateway Interface(CG)….,,,,,,,,,……,……71
91 URL Syntax Construction:……………
71
9.1. 1 Assigning a New values to a variable
71
9.2 CGI Variable: Settings(setting. cgi).m.
72
9.3 Thresholding CGI(moncon. cgi)
…72
9.4 CGI Variable: Configurations(config. cgi)
73
9.5cG| Variable: Communications(comm.cgi)………74
10.TCPInterface75
10.1 Command Codes
10.2 Read F/T Command
555
10.3 Read FIT Response....
10.4 Read calibration Info command mmm. 76
10.5 Read Calibration Info Response........
76
10.6 Write Tool transform Commandism 77
10.7wrIteMonitorconditioncommandwwwwwww.77
10.8 Write Response…
1. System Settings XML Pages.mmtesetaeeeat
78
11.1 System and Configuration Information (netftapi2 xml).m.m.mam.
78
11.2 Calibration Information( netftcalapixm)…......…………80
12. UDP Interface Using RDT....
81
121 RDT Protocol
81
12.1.1 RDT Request For Records structure
.82
12.1.2 RDT Records sent structure
82
12.2 Calculating FiT Values for RDT
83
12.3 Multiple Clients....
124 Notes on UdP and rdt mode
83
12.5 Example Code.……,,…,…,,…,…,,…,…,…,…,…,…,…,……,…83
13.Maintenancewwwww....84
13.1 Periodic Inspection
84
13.2 Periodic Calibrating..
84
14. Troubleshooting
84
141 Errors Powering Up..........……85
142 Errors with Communications
85
14.3 Errors with the java demo
86
14.4 Errors with Ethernet Axia Webpages.
86
14.5 Errors with Force and Torque Readings...
87
PinnaePark·1031Goodworthdrive·Apex,NO27539·e:+19197720115·Fax+1919728259·www.ati-a.com
Manual. F/T Sensor Ethernet Axia
Document #9610-05-Ethernet Axia-O7
14.6 Reducing Noise.,,,,..,.,,,,,,,,,
87
14.6. Mechanical vibration
87
146.2 Electrical Interference
87
14.7 Detecting Sensitivity Changes...ea.
量B日量BB量国日m自面重B量日画BB量面Ba量日B量B量B重面1日日B日
14.8 mproving Ethernet Throughput………….…………………………………88
14.8.1DirectConnectionbetweenaxiaethernetandhost..wwwwwwww..88
14.8.2 Choice of Operating System
14.8.3 Increasing Operating System Performance
88
14.8.4 Avoid Logging the Host to a Company Network
89
148.5 Use a dedicated Network
Q
15. Specifications...,………,,…89
15.1 Environmenta| Conditions.,,,,,……,……
89
152 Electrica| Specifications…,……
89
15.3 Calibration Ranges
89
16. Drawings
90
16.1 Axia80 Force/Torque sensor 9230-05-1543
90
16.2 Cable, Axia Sensor to 8-pin M12, 3m, 9105-C-2C22-ZC28-4.
92
16.3 Cable, 8-pin M12 Split to Shielded RJ45 and Unterminated power, ground, shield,4,93
9105-CZc28U-RJ455-4…
17. Terms and conditions of sale………94
Pinnacepark:1031G0rthdrive·Apex,NO27539·e:+191920115·5a+1919,728259·www,ati-|a.com
Manual. F/ Sensor. Ethernet Axia
Document #9610-05-Ethernet axia-07
Glossary
Term
Definitions
Active Configuration
The configuration that the system is currently using
ADC
Analog-to-digital converter
Calibration
The factory-supplied data used by ethernet Axia sensor so it can report accurate
sensor readings. Calibrations apply to a specific loading range
CGI
Common Gateway Interface(CGI)is the method of using web URLS to communicate
data and parameters back to a web device
Complex Loading
Any force or torque load that is not purely in one axis
Configuration
User-defined settings that include which force and torque units are reported and
which calibration is to be used
Control panel
A feature on a personal computer operating system where the user can adjust
system settings
Coordinate frame
See Point of origin
Data rate
How fast data can be output over the network
Dynamic Host Configuration Protocol (DHCP)is an automatic method for Ethernet
DHCP
equipment to obtain an IP address. The ethernet Axia system can obtain its IP
address using dHCP on networks that support this protocol
DINT
Signed double integer(32 bit)
ENABL
Boolean that uses Enabled to represent 1 and Disabled to represent O
Ethernet
A family of computer networking technologies commonly used in local area networks
Fieldbus
a generic term referring to any one of a number of industrial computer networking
standards Examples include: ethernet, can, Modbus and Profinet.
FT or F/T
Force and Torque
The resultant force vector comprised of components F, andF
HEXn
Hexadecimal number of n bits, prefixed with Ox
a standard and common method that a user can request data from a specified
Http Get Method
resource such as a sensor . Http works as a request-response protocol between
client (web browser)and server(the sensor)
a source of measurement error caused by the residual effects of
Hysteresis
previously applied loads
INT
Signed integer(16 bit
A separate plate that attaches the sensor to another surface Interface plates are
often used if the bolt pattern on the mAP or taP doesn't match the bolt pattern on the
Interface Plate
robot arm or customer tooling. The interface plate has two bolt pattens on either side
of the plate. One side is for the MAP or TAP. The other side is for the robot arm or
customer tooling
Ingress protection rating designates protection against dust and splashing of
P64
water. An IP64 rating does not guarantee protection when a user submerges a device
in water or any type of fluid
An IP Address (Internet Protocol Address)is an electronic address assigned to an
IP Address
Ethernet device so that it may send and receive Ethernet data IP addresses may be
either manually selected by the user or automatically assigned by the dHCP protocol
Java is a programming language often used for programs on web pages. The
Java Tm
Ethernet Axia demo is a Java application. Java is a registered trademark of Sun
Microsystems, Inc
MAC
Media Access Controller is the hardware that implements the lowest sub-layer of the
data link layer
MAC Addresses(Media Access Control Addresses) are the unique addresses
MAC Address
given to every Ethernet device when it is manufactured, to be used as an electronic
Ethernet serial number
PnnadePark1031GoodworthDrive.apex,Nc27539.tel:+1919.772.0115.fax:+1919.772.8259.www.ati-ia.com
Manual. F/ Sensor. Ethernet Axia
Document #9610-05-Ethernet Axia-07
Term
Definitions
MAC ID
Media Access Code Identifier(MAC iD) is a unique number that is user assigned to
each device on an ethernet network also called node address
Mounting Adapter Plate I MAP The surface of the sensor that attaches to a fixed surface like an interface
plate or robot arm
NA
Not Applicable
NVI
Non-Volatile Memory Storage of information or device memory that can be retrieved
even after the device goes through a power cycle
The condition where more load is applied to the sensor than the rated measurement
Overload
range that can be applied to the sensor Overloads result in reduced accuracy and
potentially reduced sensor life
Plug-in Technology
A customized program that when downloaded and installed onto a host device adds
a specific feature to an existing computer program
P/N
Part number
Point of origin
The location on the sensor from which all forces and torques are measured. Also
known as the coordinate frame
Power Cycle
When a user removes and then restores power to a device
REAL
Floating-point number (32 bit
The rate per second at which the sensor sends streaming Rdt data to a
RDT
host. Raw Data Transfer(RDT)is a fast and simple Ethernet protocol for control and
data transfer via UdP
A mode where the sensor sends more than one data package per sample. Multiple
RDT Buffer size
data packages are buffered and sent in one block. Buffering reduces the amount of
overhead data sent from the sensor and reduces the overall network traffic
Resolution
The smallest change in load that can be measured
Sample Rate
How fast the ADCs are sampling inside the unit
The atl f/T sensor detects sense loads that are a cumulation of forces and
Sense loads
torques acted upon the customer tooling
Sensor
The component that converts a detected load into electrical signals
SINT
Signed short integer(8 bit)
STRINGn
String of n characters
Status Bit
A unit of computer data sent from the AtI F/T sensor
TCP
Transmission Control Protocol (TCP)is a low-level method of transmitting data over
Ethernet TCP provides a slower, more reliable delivery of data than UDP.
A software function of the sensor that performs a simple arithmetic comparison of a
Thresholding
user-defined threshold to the loading on a transducer axis
Every transducer is also( or has) a sensor but every sensor isnt a transducer. A
Transducer
transducer is more than a sensor. It consists of a sensor/actuator along with signal
conditioning circuits
The resultant torque vector comprised of components T and T
UART
Universal asynchronous receiver transmitter
UDINT
Unsigned double integer(32 bit)
UDP
UDP (User Datagram Protocol) is a low-level method of transmitting data over
Ethernet. while udP is faster than tcp unlike tcp lost udp data is not resent
UINT
Unsigned integer(16 bit
USINT
Unsigned short integer(8 bit
PnnadePark1031GoodworthDrive.apex,Nc27539.tel:+1919.772.0115.fax:+1919.772.8259.www.ati-ia.com
10
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.