文件名称:
恒河YOKOGAWA FA-M3 YHLSmasterModule用户手册.pdf
开发工具:
文件大小: 1mb
下载次数: 0
上传时间: 2019-10-31
详细说明:恒河YOKOGAWA FA-M3 YHLSmasterModule用户手册pdf,恒河YOKOGAWA FA-M3 YHLSmasterModule用户手册Applicable Product
O Range-free Multi-controller FA.M3
Model code
F3LH02-0N
Name
YLHS Master module
The document number and document model code for this manual are given below
Refer to the document number in all communications also refer to the document
number or the document model code when purchasing additional copies of this manual
Document no
IM34M6H46-01E
Document model code. docIm
M34M6H46-01
1st Edition: Nov. 1. 2005-00
Media No I M 34M16H46-01E(CD) 1st Edition: Nov 1, 2005-00(AR)
All Rights reserved Copyright a 2001. Yokogawa Electric Ccrporat
mportant
■ About this manual
This Manual should be passed on to the end user
Before using the controller, read this manual thoroughly to have a clear
understanding of the controller
This manual explains the functions of this product, but there is no guarantee that
they will suit the particular purpose of the user.
Under absolutely no circumstances may the contents of this manual be transcribed
or copied, in part or in whole, without permission
The contents of this manual are subject to change without prior notice
Every effort has been made to ensure accuracy in the preparation of this manual
However, should any errors or omissions come to the attention of the user, please
ontact the nearest yokogawa electric representative or sales office
Safety Precautions when Using/Maintaining the Product
The following safety symbols are used on the product as well as in this manual
Danger. This symbol on the product indicates that the operator must follow the
instructions laid out in this instruction manual to avoid the risk of personnel injuries
fatalities, or damage to the instrument. Where indicated by this symbol, the manual
describes what special care the operator must exercise to prevent electrical shock
or other dangers that may result in injury or the loss of life
Protective Ground Terminal. Before using the instrument, be sure to ground this
termina
Function Ground Terminal. Before using the instrument, be sure to ground this
terminal
Alternating current. Indicates alternating current
Direct current. Indicates direct current
M34M6H46-01
1st Edition: Nov. 1. 2005-00
The following symbols are used only in the instruction manual
WARNING
Indicates a Warning
Draws attention to information essential to prevent hardware damage, software
damage or system failure
CAUTION
Indicates a Caution
Draws attention to information essential to the understanding of operation and
functions
TIP
ndicates a“T|P
Gives information that complements the present topic
SEE ALSO
Indicates a"SeE also reference
Identifies a source to which to refer
For the protection and safe use of the product and the system controlled by it, be
sure to follow the instructions and precautions on safety stated in this manual
whenever handling the product. Take special note that if you handle the product in
a manner other than prescribed in these instructions, the protection feature of the
product may be damaged or impaired. In such cases, Yokogawa cannot guarantee
the quality, performance function and safety of the product
When installing protection and/or safety circuits such as lightning protection devices
and equipment for the product and control system as well as designing or installing
separate protection and/or safety circuits for fool-proof design and fail-safe design of
processes and lines using the product and the system controlled by it, the user
should implement it using devices and equipment, additional to this product
If component parts or consumable are to be replaced be sure to use parts specified
by the company
This product is not designed or manufactured to be used in critical applications
which directly affect or threaten human lives and safety-such as nuclear power
equipment, devices using radioactivity, railway facilities, aviation equipment, air
navigation facilities, aviation facilities or medical equipment. If so used, it is the
user's responsibility to include in the system additional equipment and devices that
ensure personnel safety
Do not attempt to modify the product
Exemption from Res ponsibility
Yokogawa Electric Corporation(hereinafter simply referred to as Yokogawa Electric
makes no warranties regarding the product except those stated in the WARranTY
that is provided separately
Yokogawa Electric assumes no liability to any party for any loss or damage, direct or
indirect, caused by the use or any unpredictable defect of the product
M34M6H46-01
1st Edition: Nov. 1. 2005-00
Software Supplied by the Company
Yokogawa Electric makes no other warranties expressed or implied except as
provided in its warranty clause for software supplied by the company
Use the software with one computer only. You must purchase another copy of the
software for use with each additional computer.
Copying the software for any purposes other than backup is strictly prohibited
Store the original media, such as floppy disks, that contain the software in a safe
place
Reverse engineering, such as decompiling of the software, is strictly prohibited
No portion of the software supplied by Yokogawa Electric may be transferred
exchanged, or sublet or leased for use by any third party without prior permission by
Yokogawa Electric
M34M6H46-01
1st Edition: Nov. 1. 2005-00
General Requirements for Using the FA-M3 Controller
O Avoid installing the FA-M3 controller in the following locations:
Where the instrument will be exposed to direct sunlight, or where the operating
temperature exceeds the range 0°cto55°℃(32°Fto131F)
Where the relative humidity is outside the range 10 to 90%, or where sudden
temperature changes may occur and cause condensation
Where corrosive or flammable gases are present
Where the instrument will be exposed to direct mechanical vibration or shock
Where the instrument may be exposed to extreme levels of radioactivity
o Use the correct types of wire for external wiring
Use copper wire with temperature ratings greater than 75c
O Securely tighten screws
Securely tighten module mounting screws and terminal screws to avoid problems
such as faulty operation
Tighten terminal block screws with the correct tightening torque as given in this
manua
O Securely lock connecting cables
Securely lock the connectors of cables, and check them thoroughly before turning
on the power
O Interlock with emergency-stop circuitry using external relays
Equipment incorporating the FA-M3 controller must be furnished with emergency-
stop circuitry that uses external relays. This circuitry should be set up to interlock
correctly with controller status(stop/run)
o Ground for low impedance
For safety reasons, connect the [FG] grounding terminal to a Japanese Industrial
Standards(JIs)class d(earlier called Class 3 ) Ground. For compliance to CE
Marking use braided or other wires that can ensure low impedance even at high
frequencies for grounding
1 Japanese Industrial Standard (JIS)Class D Ground means grounding resistance of 100 Q2 max
o Configure and route cables with noise control considerations
Perform installation and wiring that segregates system parts that may likely become
noise sources and system parts that are susceptible to noise. Segregation can be
achieved by measures such as segregating by distance, installing a filter or
segregating the grounding system
Configure for CE Marking Conformance
For compliance to CE Marking, perform installation and cable routing according to
the description on compliance to CE Marking in the"Hardware Manual
(M34M6C1101E
M34M6H46-01
1st Edition: Nov. 1. 2005-00
o Keep spare parts on hand
Stock up on maintenance parts including spare modules, in advance
Discharge static electricity before operating the system
Because static charge can accumulate in dry conditions, first touch grounded metal
to discharge any static electricity before touching the system
O Never use solvents such as paint thinner for cleaning
Gently clean the surfaces of the FA-M3 controller with a cloth that has been soaked
in water or a neutral detergent and wringed
Do not use volatile solvents such as benzine or paint thinner or chemicals for
cleaning, as they may cause deformity, discoloration, or malfunctioning
Avoid storing the FA.M3 controller in places with high temperature or
humidity:
Since the CPU module has a built-in battery, avoid storage in places with high
temperature or humidit
Since the service life of the battery is drastically reduced by exposure to high
temperatures, take special care(storage temperature should be from -20C to
75°C)
There is a built-in lithium battery in a CPU module and temperature control module
which serves as backup power supply for programs device information and
configuration information. The service life of this battery is more than 10 years in
standby mode at room temperature. Take note that the service life of the battery
may be shortened when installed or stored at locations of extreme low or high
temperatures. Therefore, we recommend that modules with built-in batteries be
stored at room temperature.
Always turn off the power before installing or removing modules
Failing to turn off the power supply when installing or removing modules, may result
in damage
o Do not touch components in the module
In some modules you can remove the right-side cover and install ROM packs or
change switch settings. While doing this, do not touch any components on the
printed-circuit board, otherwise components may be damaged and modules may fail
to work
O Do not use unused terminals
Do not connect wires to unused terminals on a terminal block or in a connector
Doing so may adversely affect the functions of the module
M34M6H46-01
1st Edition: Nov. 1. 2005-00
ntroduction
■ Overview of the manua
This manual describes the specifications, operations, and communications protocol of
the YHLS (Yokogawa High-speed Link System)master module F3LHO2-0N
Related Instruction Manuals
The manuals to be read depend on the cpu module to be used
You should read the latest versions of the following instruction manuals as required
O F3SP28F3SP38, F3SP53. F3SP58, or F3SP59
For information on sequence cPu functions, refer to
Sequence CPU Instruction Manual -Functions (for F3SP28-3N/3S, F3SP38-6N/6S
F3SP53-4H4S,F3SP58-6H6S,F3SP59-7s)(M34M6P13-01E)
For information on sequence cPu instructions, refer to
Sequence CPU Instruction Manual -Instructions(IM34M6P12-03E
For information on creating ladder programs, refer to
FA-M3 Programming Tool Wide Field2(IM34M6Q15-01E)
0 F3SP21F3SP25, F3SP35F3SP05, or F3SP08
For information on sequence cPu functions, refer to
Sequence CPU Instruction Manual -Functions(for F3SP21, F3 SP25, and F3SP35)
(IM34M6P1202E)
For information on sequence CPU instructions, refer to
Sequence CPU Instruction Manual -Instructions(IM34M6P12-03E)
For information on creating ladder programs, refer to
FA-M3 Programming Tool WideField2 (IM34M6Q15-01E)
All sequence CPU modules
For the FA-M3 specifications and configurations installation and wiring test run
maintenance. and module installation restrictions refer to
1: Refer to the relevant product manuals for specifications except for power supply modules, base modules, input/output
modules. cables and terminal units
Hardware Manual (IM34M6C11-01)
M34M6H46-01
1st Edition: Nov. 1. 2005-00
Copyrights and Trademarks
Copyrights
Copyrights of the programs and online manual included in this CD-ROM belong to
Yokogawa Electric Corporation
This online manual may be printed but PdF security settings have been made to prevent
alteration of its contents
This online manual may only be printed and used for the sole purpose of operating this
product. When using a printed copy of the online manual, pay attention to possible
inconsistencies with the latest version of the online manual. ensure that the edition
agrees with the latest CD-ROM version.
Copying, passing, selling or distribution(including transferring over computer networks
of the contents of the online manual, in part or in whole, to any third party, is strictly
prohibited. Registering or recording onto videotapes and other media is also prohibited
without expressed permission of Yokogawa Electric Corporation
■ Trademarks
trademarks or registered trademarks of their respective companies Da
The trade and company names that are referred to in this document are either
M34M6H46-01
1st Edition: Nov. 1. 2005-00
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.