您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 东芝VF-A5说明书.pdf
  所属分类: 其它
  开发工具:
  文件大小: 9mb
  下载次数: 0
  上传时间: 2019-10-31
  提 供 者: weixin_********
 详细说明:东芝VF-A5说明书pdf,东芝VF-A5说明书E6580516 Introduction Thank you for purchasing the Toshiba High-Performance Inverter"TOSVERT VF-A5" The"VF-A5"inverter has many various functions built in for use with a 3-phase induction motor. All Operations of this unit are done via the easy-to-use keyboard-type operation panel. A blind function (Refer to page 55)that displays only those functions required for operation, and an edit function(Refer to page 34)that automatically collects parameters that differ from their default settings are used to make basic operation and setting easier. Advanced control technology features (sensorless vector control feedback control, current limit, retry, and stall prevention functions) are built in, so that the inverter will not trip easily, and will provide unparalleled reliabilty Please read this manual thoroughly before use to properly understand the correct use of the outstanding functions of the "VF-A5' This manual should be stored by the user of the"VF-A5 for reference during maintenance and inspection Symbols used in this manual are as shown below. Understand them before reading this manual 1. LEd display character codes: Reter to page 131 2. To indicate a parameter display on the operation panel in this manual: P Example sCC日 To indicate a panel key Example LENTER key The box l is not used when indicating parameter group names and parameter settings Note)The box L is not used when displaying parameters in tables E658051 Table of contens 1. Acceptance Inspection and Precautions 2. Installation Precautions 3. Extemal View and Component Names ..,. peration Precautions . 5 5. Wiring Precautions 6. Standard Connections 15 6.1 Standard Connection Example 15 62 Terminal Functions……18 7. Operation and Adjustment 。b看·鲁鲁看 7.1 Operation Panel 32 7,2 Basic Operation…; 7.3 Operation Modes… 37 7. 3. 1 Standard Monitor Mode 37 7.3.2 Status Monitor Mode 7. 3. 3 Setting Monitor Mode 41 7.3.4 JOG Run Mode 7.4 Operation Mode selection 45 7.4.1 Operation Mode Changeover 742 Run/Stop Command[Ceir是]…………45 7.4.3 Frequency Command Source Setting Function FHEid in Lir.Lik 45 4.4 Parameter Setting Function[ FHie in ErLik] 46 7.4.5 Standard Parameter Value Reset Function [k≌尸inp]…47 7.4.6 Selection of Stopping Method from the pane 48 7.4.7 Fault reset 8. Parameter Explanations 50 1. ErF V/f settings 50 V/f pattern① 51 V/f pattern② 52 Acceleration/deceleration time settings 53 Acc/Dec patterns, AcC/Dec pattern adjustment, LoW/High 54 Blind function selection 55 Upper limit/lower limit frequencies Reverse operation disable selection 56 E6580516 2. ir.Fr" Acc/dec#1and# selection…………………………………………57 Pane| feedback contro………………………… 58 Panel reset selection ...·.·.“··:··=··=·=; 58 Fundamental parameter switching 59 3. Er.St Input terminal selections (1 60 Input terminal selections(2 61 Output terminal selections (1 62 Output terminal selections 2 63 Low speed, acceleration/deceleration complete, speed reach output signals 64 nput/output terminal response time selections 55 Commercial power/INV switching …-66 Output terminal pulse frequency selection 67 RR input special function selection 67 4. Ers Run frequency col 68 Start-up frequency/End frequency --............................69 Jump frequencies… 70 PWM carrier frequency…… 5 SF Preset speed operation (1 72 Preset speed operation (2) Frequency priority selections 74 Jogging operation 75 Frequency setting input signal characteristics 76 6. Er"F,- Electronic thermal protection (1 Electronic thermal protection (2) DC injection braking settings (1 DC injection braking settings( 2) 81 Dynamic braking operation 82 Emergency stop 83 Retry function 83 Regeneration power ride-through control 84 Auto- restart………………………… Trip function selections 85 Output short circuit detection selection 85 Fault trip saving… 7.5- Fk Pattern run① 87 Pattern run② 88 E6580516 8. Eir.Lt Panel operation permission 89 Industrial application parameters selection 90 Standard setting mode selection…………90 Command/ frequency mode selections Status monitor display selections 92 Blind function selection 92 Units settings 93 9. rff Meter adjustment parameters 94 9. Device Specifications 95 9.1 Model and standard Specifications 95 92 External Dimensions…………………………………… 99 10. Options 103 1. Error displays and Troubleshooting 105 11.1 Inverter Trip causes and remedies 105 11.2 Other Fault Troubleshooting ----- 109 12. Maintenance and Inspection…………………110 12.1 Preventive Maintenance and periodic Inspection 110 12.2 Component Replacement ········“ 111 13. Storage 112 14. Warranty 112 Appendix Appendix table1. Parameter list…… 113 Appendix Table 2. List of trip 129 Appendix Figure 1. Input terminal information 130 Appendix Figure 2. Output terminal information 130 Appendix figure3. Character codes∴………………………131 Appendix Table 3. Standard default settings per inverter capacity 132 Appendix Table 4. Industrial application parameters 133 Appendix Table 5. Changed settings memo E6580516 1. Acceptance Inspection and Precautions (1) Confirm that the unit has not been damaged during shipment (2)Confirm that the model noted on the rating nameplate is as ordered 3)When storing the unit temporarily after purchase, store it in dust-free, well-ventilated location (4)Special care is taken during product manufacturing, packaging, and shipment. If any problems are discovered, however, please contact your dealer immediately. Detailsof rating nameplate TRANSISTOR INVERTER a TYPE-FORM VEA5-2037P Inverter model Applicable SOURCE 200-220V-50H2 FREQUENCY 0.1-80Hz -Rated output frequency power source 200-230V560Hz (0.01-400)H Capacity CAPACITY 6.5 KVA CURRENT 165A Rated output current Rated output→- VOLTS 200-230V AC MOTOR 3.7 KW MAX voltage Applicable motor capacity LOT NO. i M6584991P MADE IN JAPAN Details of model no Model n tion PcB Type Model specification VPA同S-O|3|7P冈-A|2|2 Model name Standard Additional motor functions Option PCB and special specification codes TOSVERT capacity 口口: Special specification code(口口are VF-A5 series E: Fully enclosed[ M: 12-bit binary input PCB 4526A install numbers A: General pur 04kW:004 F: External Q: Expansion terminal block PCB 45 14A installed pose high- 075kW:007 heatsink R: Expansion terminal block PCB 4514B installed performance 15kW:015 N: GTR7 22kW:022 odification S: Expansion terminal block PCB 4514C installed 37kW:037 T: Expansion terminal block PCB 4514D installed Input voltage 55kW:055 J: Expansion terminal block PCB 4515A installed 2:200v-230V 75kW:075 1(nonstandard) K: ExDanso terminal block PCB installed lone: Standard 4:380-460V 11kW:110 D: Expansion terminal block PCB 4515C installed 8: DC power source 15kW:150 V: RS485 communication PCB installed TOSLINE-F1oM communication PCB install input 185kW:185 (200V class output) 22kW:220 Operation X: TOSLINE-F20 communication PCB installer panel 9: DC 30kW:300 37kW:370 P: Installed B: Not installed (400V class output UL-listed: UP. UB 75 90kW:900 110kW:11 132kW:132k 160kW:160k 220kW:220k 280kW:280k E6580516 2. Installation Precautions This inverter is an electronic control unit. Take special care concerning the installation environment Confirm that the input power is within +% of the rated value If the input power voltage range tolerances are exceeded during use, the protective circuits may function or the inverter may be damaged Avoid installation in hot and humid locations Use the unit within an ambient temperature of where condensation or freezing may occur, or -10to40℃ where water, dust, or metal chips may come into Because the inverter radiates contact with the inverter 2动线 heat, when installing in a · Install in a location d panel take special care free of corrosive gases concerning ventilation and E/ or cutting fluids, etc panel space. Removal of the cover is recommended 10℃ using in a pan ensure maximum longevity and reliability. Do not install the unit The inverter may malfunction if the locations that following types of devices are experience large stalled nearby, so use proper vibrations precautions Solenoid Install a surge kill Brake the exciting coil Electromagnetic Resistor contactors Fluorescent lights Resistors Keep away from the inverter Ground the g/E Attach the unit to a non-combustible material such as a metal panel. to terminal to prevent ensure adequate ventilation, maintain the following installation spaces, and electrical shock and always install the unit vertically in the longitudinal direction. When installing malfunction due to multiple inverters in a row, leave a clearance of noise 10cm or at least 10cm between each unit this clearance more can be reduced depending on the environment 5cm or more 5cm or or by adding fans more (For 37kW and larger units, leave a clearance of at least 20 re and below the inverter to 10cm or more allow for fan replacement and wire bending space. Contact the Engineering department for furthe details Inverter life depends greatly on the ambient temperature make sure that the ambient temperature of the installation location dose not exceed the Measure the temperature at the positions shown in the diagram on the right, tcm maximum ambient temperature rating(40C) 会|5cn and confirm that it is less than the maximum ambient temperature rating Measurement 40C).(50C or less when the cover is removed. 22kW and larger units can be used up to an ambient temperature of 50C (Do not remove the cover from 22kW and larger units Measurement position x Always install the inverter in the longitudinal direction on a vertical surface E6580516 3. External view and component Names 3.1 Component Explantion (I) d Cooling air exhaust port ⑥ Mounting hole4 holes) ⑤ Upper caution sticker ⑦ Mounting bracket ⑥ Chassis( plastic ① Operating pane ⑨ Ventilation slots ② ROM interface window d Optical cable access slot semi-transparent for installation of optical communication options ③ Front cover wamings ① Finger clasp for (I) removIng cover ① Rating nameplate (I) 白I) 1(12 Cooling ④ Cover(astl Wiring access plate Always cut out the wiring pons as necessary. an 11kw or larger unit, te rubber bushing or a knife as OOperating panel:removable hown below Refer to section 3. 3 Removal of operating panel 2 ROM interface window: removable Rubber Refer to section 3. 3 Removal of ROM inetrface window bushing ④ Cover 5 Upper caution sticker Always read the cautions on the tront of the cover and remove Always remove this sticker when the ambient the cover when wiring temperature is high Refer to section 3.2 Removal of cover ⑨ Ventilation slots: If the ambient temperature of the inverter unit exceeds 40C when A cover-up plate option is available for fully-sealed mounted in a panel, remove the cover the unit can then be used applications. up to a temperature of 50C 3.2 Removal of cover 1)For 7.5kW and smaller. Place your fil on the finger clasps for removing the cover shown in the 3. 1 Component Explanation (Drawing force in the direction of the aows(I), and pull the cover up in the direction of arrow e covel 2)For 11-18.5kW. Remove the two screws on the cover wiring inlet, and then remove the cover like the 7. 5kW models 2)For 22*W and larger- Wait for the"CHARGE"lamp on the cover(sheet metal to go out. then remove the four screws holding the cover(six screws for 37kW and larger), and the cover will come off Hook structure Fitting structures 仓(I) 广|m E6580516 3.3 Removal of the rom Interface Window and operation Panel KLV Operation panel RUN LSTOP (Ⅳ) SET (I) USH ROM interface window ( Press where the word PUSH is located (I) The operation panel attachment screw can now be seen Turn it The top of the window will open in the direction of the arrow I)unit it completely (I)Hold the top of the window, an loosens pull it out in the direction of (M) When the screw has the arrow( completely loosened, pull the operation panal out in the direction of the arrow(v) 3.4 Component Explantion(1) Option connector (40-pin) ② Operation panel RS232C communicationN connector onnector (Modular 6-pi Option ROM socket、 ② Operation panel attachment stud ⑨ ROM cover 26 Changeover switch for frequency setti signal inputs V terminal i/ changeover switch 口‖ RX terminal10V/5 changeover switch 2)Option connector (20-pin) ② 日 Control terminal block 囵圈圈 ② Flat cable _啊备 (for control terminal block)
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 相关搜索: 东芝VF-A5说明书.pdf
 输入关键字,在本站1000多万海量源码库中尽情搜索: