您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 三菱PLC A1SJ71QC24通讯模块用户手册.pdf
  所属分类: 其它
  开发工具:
  文件大小: 480kb
  下载次数: 0
  上传时间: 2019-10-31
  提 供 者: weixin_********
 详细说明:三菱PLC A1SJ71QC24通讯模块用户手册pdf,三菱PLC A1SJ71QC24通讯模块用户手册○ SAFETY PRECAUT|oNs (Read these precautions before using When using Mitsubishi equipment, thoroughly read this manual and the associated manuals introduced in the manual. Also pay careful attention to safety and handle the module properly These precautions apply only to Mitsubishi equipment. Refer to the CPU module user's manual for a description of the Pc system safety precautions These SAFETY PRECaUTIoNS classify the safety precautions into two categories: "DANGER"and CAUTION ◇ DANGER Procedures which may lead to a dangerous condition and cause death or serious injury if not carried out properly. △ CAUTION Procedures which may lead to a dangerous condition and cause superficial to medium injury, or physical damage only, if not carried out properly. Depending on circumstances, procedures indicated by A CAUTION may also be linked to serious results In any case, it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user DESIGN PRECAUTIONS] ◇ DANGER When performing the control of the PC in operation ( especially changing data, program, and operation status(status control)) by connecting a personal computer, etc to the special function module configure an interlock circuit in a sequence program so the safety of the overall system Is always maintained Especially, when this control is performed to a remote PC from an extemal device, troubles that have occurred on the Pc side may not be able to immediately be handled if there is a data communication error define a troubleshooting agreement between external devices and the pc cPu for data communication error occurrences. as well as construct an interlock circuit in the sequence program [DESIGN PRECAUTIONS] △ CAUTION Do not bunch the control wires or communication cables with the main circuit or power wires, or install them close to each other They should be installed 100mm ( 3.9 inch)or more from each other Not doing so could result in noise that would cause erroneous operation INSTALLATION PRECAUTIONS △ CAUTION Use the Pc in an environment that meets the general specifications contained in this manual. Using this Pc in an environment outside the range of the general specifications could result in electric shock, fire, erroneous operation and damage to or deterioration of the product. Switch all phases of the extenal power supply off when installing or placing wiring. Not doing so could result in electric shock or damage to the product Insert the tabs at the bottom of the module into the mounting holes in the base unit. Then tighten the module installation screws with specified torque. If the module is not properly installed, it may result in malfunction breakdowns, or the module may fall off Tighten the screw within the range of specified torque If the screws are loose, it may result in fallout, short circuits, or malfunction Tightening the screws too far may cause damages to the screws and/or the module, resulting in a fallout, short circuits, or malfunction Do not directly touch the module' s conductive parts or electronic components. doing so could cause malfunction or trouble in the module Perform correct pressure-displacement, crimp-contact or soldering for wire connections using the tools specified by the manufactures. Attach connectors to the module securely WIRING PRECAUTIONS] △ CAUTION Be sure to secure communication cables in ducts or fix them with cramps Failure to do so may cause a damage to the module or cables due to dangling, shifting or inadvertent handling of cables, or misoperation due to bad cable connection Before connecting the cables, check the type of interface to be connected Connection, or erroneous wiring, to the wrong interface may damage the module and external devices Tighten the terminal screw within the range of specified torque If the screws are loose, it may result in short circuits or malfunction Tightening the screws too far may cause damages to the screws and/or the module, resulting in a fallout, short circuits, or malfunction Do not grab on the cable when removing the communication cable connected to the module When removing the cable with a connector, hold the connector on the side that is connected to the module When removing the cable without a connector, first loosen the screws on the part that is connected to the module Pulling the cable that is still connected to the module may cause a damage to the module or cable or misoperation due to bad cable contacts Be sure there are no foreign substances such as sawdust or wiring debris inside the module. Such debris could cause fires, damage, or erroneous operation STARTING AND MAINTENANCE PRECAUTIONS] ◇ DANGER Do not touch the connector while the power is on. doing so could cause erroneous operation. Switch all phases of the external power supply off before cleaning or re- tightening screws. If you do not switch off the external power supply, it will cause failure or malfunction of the module If the screws are loose it may result in fallout, short circuits or malfunction Tightening the screws too far may cause damages to the screws and/or the module, resulting in a fallout, short circuits, or malfunction STARTING AND MAINTENANCE PRECAUTIONSI △ CAUTION Do not disassemble or modify the modules. Doing so could cause trouble, erroneous operation, injury, or fire Switch all phases of the external power supply off before mounting or removing the module. If you do not switch off the external power supply, it will cause failure or malfunction of the module TOPERATING PRECAUTIONSI ◇ DANGER Do not write data into the system area" of the buffer memory of special function modules. Also, do not output the" prohibited to use" signal as the output signal to a special function module from the PC CPu Writing data into the"system area"or outputting a signal for" prohibited to use"may cause system malfunctions in the Pc △ CAUTION Before performing the control of the Pc in operation(especially changing data, program, and operation status (status control)) by connecting a personal computer, etc to the special function module, read the manual carefully and confirm if the overall safety is maintained Failure to perfom correct operations to change data, program, or the status may result in system malfunction, machine damage, or an accident When using the module while values, such as buffer memory set values, are registered in the EEPROM, do not turn off the power supply for the module loading station nor reset the PC CPU If the power supply for the module loading station is truned off or the pc CPU is reset while any values are registered, the data contents in the EEProM become inconsistent and as a result the values must be set again in the buffer memory, etc and reregistered to the EEPROM. also this may cause failure and malfunction of the module [DISPOSAL PRECAUTIONST △ CAUTION When disposing of this product, treat it as industrial waste. Table of contents About this manual 1. Overview 2. Transmission Specifications 3. Name of Each Part and Setting 4. Mounting and Installation 4.1 Handling Precautions 42 Installation environment 48889 5. External Wiring ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ 5.1 Connecting rs-232C line 5.2 Connecting rs-422/485 Line 12 6. External dimensions 18 About this manual The following product manuals are available. please use this table as a reference to request the appropriate manual as necessary Related manual Manual names Manual no (Model Code) Serial Communications Module guidebook B66622 (13JF11 Serial communications module user's manual B66612 (13J825)*1 Computer Link Guidebook SH-3510 (13JE76) Computer Link/Multidrop Link Module User's Manual SH3511 (Computer Link Function, Printer Function) (13JE77) AlSJ71QC24(-R2)'s updated information is added in the manual printed after manual B-66612-B Please read serial Communications module user's manual before using this module Correspondence to EMC DIRECTIVE "EMC AND LOW-VOLTAGE DIRECTIVE"in the PC CPU userster 2 To make the pcs compliant with the emc directive, refer to chapter 2 manual (Hardware) When the PC CPU user's manual(hardware)does not include Chapter 2 EMC AND LOW-VOLTAGE DIRECTIVE refer to QnA Series CPU Compatible High-Speed Access Basic Base Unit Corresponding CPU EMC Conforming Product Additional Explanation(IB-68837)(optional) 1 Overview This manual describes how to install the following serial communications modules and how to wire them with external devices When unpacking the module, check that the products listed in the table below are present Model Product name Qt AlSJ71QC24 serial communications module ■■■l口■■■■■■■■ RS-422 communication terminal resistor 330 2 A1S71QC24|49 RS485 communication terminal resistor1o…… 2 1/2W(brown/brown/brown AlSJ71QC24-R2AlSJ71QC24N-R2 serial communication module Unless there is a need to identify each device, all of the modules are referred to as QC24 How to discriminate between the terminating resistors 330 Orange Orange Brown 110 Brown Brown Brown 2. Transmission Specifications The transmission specifications of the QC24 is shown below Refer to CPU module Users manual for Qc24 general specification Item Specifications A1SJ71QC24 A1SJ71QC24-R2 Interface CH1 RS-232C RS-232C CH2 RS422485 RS-232C Communications system Full-duplex/Half-duplex (Only Rs-232C interface is selectable Synchronous system Asynchronous system Transmission speed 19200,9600,4800,2400,1200,600,300 (Unit: bps) (Each of CH1 and CH2 selects Start bit Data format Data bit 7/8 Parity bit 1(es)/0(no) Stop bit 1/2 Item Specifications A1SJ71QC24 AISJ71QC24-R2 Error Parity check Yes(odd/even)/No detection Sum check Yes/ No ode Transmission DTR/DSR Yes(Only RS-232C interface is selectable. )/No control DC code Yes(DC1/DC3, DC2/DC4)/No Writing to EEPROM 100,000 times for the same area(Max Dedicated protocol RS232C.….1:1 Ind Non Rs422485.1:1.1n,mn conn-endent lection modeprocedure Only 1: 1 can be used for the bidirectional protocol protocol Bidirectional m: n can only be used for a dedicated protocol protocol Dedicated 1: 0.m n protocol Linked on Communication disable procedure 1:n lode With intemal mode protocol Bidirectional I (Communication disable protocol with intemal mode Transmission distance RS-232C……15m(492f.) or less RS422/485.1200m(3937.0f.) or less Power consumption 5VDC 0.24A 0.155A Number of /0 points 32 points(1) Weight: kg(Ib) 0294(0.65) 0.2490.55) Set special 32 points when allocating lo by GPP function. Set AJ71QC24"as a model name registration when using dedicated command 2
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: