详细说明:三菱PLC A1SJ71QC24通讯模块用户手册pdf,三菱PLC A1SJ71QC24通讯模块用户手册○ SAFETY PRECAUT|oNs
(Read these precautions before using
When using Mitsubishi equipment, thoroughly read this manual and the
associated manuals introduced in the manual. Also pay careful attention to
safety and handle the module properly
These precautions apply only to Mitsubishi equipment. Refer to the CPU
module user's manual for a description of the Pc system safety precautions
These SAFETY PRECaUTIoNS classify the safety precautions into two
categories: "DANGER"and CAUTION
◇
DANGER Procedures which may lead to a dangerous
condition and cause death or serious injury if not
carried out properly.
△ CAUTION
Procedures which may lead to a dangerous
condition and cause superficial to medium injury, or
physical damage only, if not carried out properly.
Depending on circumstances, procedures indicated by A CAUTION may
also be linked to serious results
In any case, it is important to follow the directions for usage
Store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user
DESIGN PRECAUTIONS]
◇ DANGER
When performing the control of the PC in operation ( especially changing
data, program, and operation status(status control)) by connecting a
personal computer, etc to the special function module configure an
interlock circuit in a sequence program so the safety of the overall system
Is always maintained
Especially, when this control is performed to a remote PC from an extemal
device, troubles that have occurred on the Pc side may not be able to
immediately be handled if there is a data communication error define a
troubleshooting agreement between external devices and the pc cPu for
data communication error occurrences. as well as construct an interlock
circuit in the sequence program
[DESIGN PRECAUTIONS]
△ CAUTION
Do not bunch the control wires or communication cables with the main
circuit or power wires, or install them close to each other
They should be installed 100mm ( 3.9 inch)or more from each other
Not doing so could result in noise that would cause erroneous operation
INSTALLATION PRECAUTIONS
△ CAUTION
Use the Pc in an environment that meets the general specifications
contained in this manual. Using this Pc in an environment outside the
range of the general specifications could result in electric shock, fire,
erroneous operation and damage to or deterioration of the product.
Switch all phases of the extenal power supply off when installing or
placing wiring. Not doing so could result in electric shock or damage to
the product
Insert the tabs at the bottom of the module into the mounting holes in the
base unit. Then tighten the module installation screws with specified
torque. If the module is not properly installed, it may result in malfunction
breakdowns, or the module may fall off
Tighten the screw within the range of specified torque
If the screws are loose, it may result in fallout, short circuits, or malfunction
Tightening the screws too far may cause damages to the screws and/or
the module, resulting in a fallout, short circuits, or malfunction
Do not directly touch the module' s conductive parts or electronic
components. doing so could cause malfunction or trouble in the module
Perform correct pressure-displacement, crimp-contact or soldering for wire
connections using the tools specified by the manufactures. Attach
connectors to the module securely
WIRING PRECAUTIONS]
△ CAUTION
Be sure to secure communication cables in ducts or fix them with cramps
Failure to do so may cause a damage to the module or cables due to
dangling, shifting or inadvertent handling of cables, or misoperation due to
bad cable connection
Before connecting the cables, check the type of interface to be connected
Connection, or erroneous wiring, to the wrong interface may damage the
module and external devices
Tighten the terminal screw within the range of specified torque
If the screws are loose, it may result in short circuits or malfunction
Tightening the screws too far may cause damages to the screws and/or
the module, resulting in a fallout, short circuits, or malfunction
Do not grab on the cable when removing the communication cable
connected to the module
When removing the cable with a connector, hold the connector on the side
that is connected to the module
When removing the cable without a connector, first loosen the screws on
the part that is connected to the module
Pulling the cable that is still connected to the module may cause a damage to
the module or cable or misoperation due to bad cable contacts
Be sure there are no foreign substances such as sawdust or wiring debris
inside the module. Such debris could cause fires, damage, or erroneous
operation
STARTING AND MAINTENANCE PRECAUTIONS]
◇ DANGER
Do not touch the connector while the power is on. doing so could cause
erroneous operation.
Switch all phases of the external power supply off before cleaning or re-
tightening screws. If you do not switch off the external power supply, it will
cause failure or malfunction of the module
If the screws are loose it may result in fallout, short circuits or malfunction
Tightening the screws too far may cause damages to the screws and/or
the module, resulting in a fallout, short circuits, or malfunction
STARTING AND MAINTENANCE PRECAUTIONSI
△ CAUTION
Do not disassemble or modify the modules. Doing so could cause trouble,
erroneous operation, injury, or fire
Switch all phases of the external power supply off before mounting or
removing the module. If you do not switch off the external power supply, it
will cause failure or malfunction of the module
TOPERATING PRECAUTIONSI
◇ DANGER
Do not write data into the system area" of the buffer memory of special
function modules. Also, do not output the" prohibited to use" signal as the
output signal to a special function module from the PC CPu
Writing data into the"system area"or outputting a signal for" prohibited to
use"may cause system malfunctions in the Pc
△ CAUTION
Before performing the control of the Pc in operation(especially changing
data, program, and operation status (status control)) by connecting a
personal computer, etc to the special function module, read the manual
carefully and confirm if the overall safety is maintained
Failure to perfom correct operations to change data, program, or the status
may result in system malfunction, machine damage, or an accident
When using the module while values, such as buffer memory set values,
are registered in the EEPROM, do not turn off the power supply for the
module loading station nor reset the PC CPU
If the power supply for the module loading station is truned off or the pc
CPU is reset while any values are registered, the data contents in the
EEProM become inconsistent and as a result the values must be set
again in the buffer memory, etc and reregistered to the EEPROM. also
this may cause failure and malfunction of the module
[DISPOSAL PRECAUTIONST
△ CAUTION
When disposing of this product, treat it as industrial waste.
Table of contents
About this manual
1. Overview
2. Transmission Specifications
3. Name of Each Part and Setting
4. Mounting and Installation
4.1 Handling Precautions
42 Installation environment
48889
5. External Wiring
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
5.1 Connecting rs-232C line
5.2 Connecting rs-422/485 Line
12
6. External dimensions
18
About this manual
The following product manuals are available. please use this table as a
reference to request the appropriate manual as necessary
Related manual
Manual names
Manual no
(Model Code)
Serial Communications Module guidebook
B66622
(13JF11
Serial communications module user's manual
B66612
(13J825)*1
Computer Link Guidebook
SH-3510
(13JE76)
Computer Link/Multidrop Link Module User's Manual
SH3511
(Computer Link Function, Printer Function)
(13JE77)
AlSJ71QC24(-R2)'s updated information is added in the manual printed
after manual B-66612-B
Please read serial Communications module user's manual before
using this module
Correspondence to EMC DIRECTIVE
"EMC AND LOW-VOLTAGE DIRECTIVE"in the PC CPU userster 2
To make the pcs compliant with the emc directive, refer to chapter 2
manual (Hardware)
When the PC CPU user's manual(hardware)does not include
Chapter 2 EMC AND LOW-VOLTAGE DIRECTIVE refer to QnA
Series CPU Compatible High-Speed Access Basic Base Unit
Corresponding CPU EMC Conforming Product Additional
Explanation(IB-68837)(optional)
1 Overview
This manual describes how to install the following serial communications
modules and how to wire them with external devices
When unpacking the module, check that the products listed in the table
below are present
Model
Product name
Qt
AlSJ71QC24 serial communications module
■■■l口■■■■■■■■
RS-422 communication terminal resistor 330
2
A1S71QC24|49
RS485 communication terminal resistor1o……
2
1/2W(brown/brown/brown
AlSJ71QC24-R2AlSJ71QC24N-R2 serial communication module
Unless there is a need to identify each device, all of the modules are
referred to as QC24
How to discriminate between the terminating resistors
330 Orange Orange Brown
110 Brown Brown Brown
2. Transmission Specifications
The transmission specifications of the QC24 is shown below
Refer to CPU module Users manual for Qc24 general specification
Item
Specifications
A1SJ71QC24
A1SJ71QC24-R2
Interface
CH1
RS-232C
RS-232C
CH2
RS422485
RS-232C
Communications system
Full-duplex/Half-duplex
(Only Rs-232C interface is selectable
Synchronous system
Asynchronous system
Transmission speed
19200,9600,4800,2400,1200,600,300
(Unit: bps)
(Each of CH1 and CH2 selects
Start bit
Data format Data bit
7/8
Parity bit
1(es)/0(no)
Stop bit
1/2
Item
Specifications
A1SJ71QC24
AISJ71QC24-R2
Error
Parity check
Yes(odd/even)/No
detection
Sum check
Yes/ No
ode
Transmission DTR/DSR Yes(Only RS-232C interface is selectable. )/No
control
DC code
Yes(DC1/DC3, DC2/DC4)/No
Writing to EEPROM
100,000 times for the same area(Max
Dedicated
protocol
RS232C.….1:1
Ind
Non
Rs422485.1:1.1n,mn
conn-endent
lection modeprocedure
Only 1: 1 can be used for the bidirectional
protocol
protocol
Bidirectional m: n can only be used for a dedicated protocol
protocol
Dedicated
1: 0.m n
protocol
Linked
on
Communication disable
procedure
1:n
lode
With intemal mode
protocol
Bidirectional I (Communication disable
protocol
with intemal mode
Transmission distance
RS-232C……15m(492f.) or less
RS422/485.1200m(3937.0f.) or less
Power consumption
5VDC
0.24A
0.155A
Number of /0 points
32 points(1)
Weight: kg(Ib)
0294(0.65)
0.2490.55)
Set special 32 points when allocating lo by GPP function. Set
AJ71QC24"as a model name registration when using dedicated
command
2
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.