您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 用于路斯特CDE3000/CDB3000伺服驱动器canopen通讯协议说明书.pdf
  所属分类: 其它
  开发工具:
  文件大小: 2mb
  下载次数: 0
  上传时间: 2019-10-20
  提 供 者: weixin_********
 详细说明:用于路斯特CDE3000/CDB3000伺服驱动器canopen通讯协议说明书pdf,用于路斯特CDE3000/CDB3000伺服驱动器canopen通讯协议说明书LUST Dear user This manual is intended for you as a project engineer: commissioning engineer or programmer of drive and automation solutions on the CANopen field bus. It is assumed that you already familiar with thi field bus on the basis of appropriate training ar f the relevant literature We assume that your drive is already in operation-if not, you should first nsult the Operation manual Note This Manual is applicable to the CDE3000 and CDB3000 position contol systems, so in the following you will see only the abbreviation s Cde and CDb used How to use this manual General introduction 2 Implemented DS301 functionality 3 Operation modes 3 4 EDS file, object directory 4 Appendix A EN User Manual CM-CANoper LUST Pictograms >Attention Misoperation may result in damage to the drive or malfunctions △△ Danger from electrical tension! Improper behaviour may endanger human life - Danger from rotating parts! The drive may start running automatically Note: Useful information User Manual CM-CANopen LUST Table of contents General introduction 1.1 Commissioning ................ 1-2 1.1.1 Parameter setting 12 1.1.2 Parameter data types III 1-2 1.1.3 Representation of data types 1.1.4 Commissioning via DRIVEMANAGER∴… 1-4 1.1.5 Necessary parameter settings.. 1-4 1.1.6 Parameter set download 12 Hardware address coding asaaaasuananssens1-5 13 Hardware pin assignment auamaaaummaa.1-5 1.4 Baud rates…1-6 15 Hardware enable 17 16 Implemented DS301 functionality 17 1.6.1 Communication objects 17 Object directory of DS301: 1.7.1 Addenda to ds301 object description ..............1-10 1.8 PDO mappin 1-11 1.8.1 Emergency object…,… 1-14 1.8.2 Error acknowledgment via bus system 1-14 18.3 Other error acknowledgment options 1-15 1.8.4 Emergency error codes table 1-15 18.5 Heartbeat function 2 Implemented dS402 functionality 2.1 Drivecom state machine 2-2 2.2 Option codes 2-2 23 Device control objects 2-6 24 Units and scalings factor group 2-7 2.4.1 Single-encoder system 2-7 2.4.2 Dual-encoder systems 2-9 EN User Manual CM-CANopen L凵sT 3 Operation modes 3.1 Operation mode selection . amanmnnnnn 3-2 3.2 DS402-compatible operation modes ..anem.. 3-3 3.2.1 State machine…3-3 3.3 Control word ds402…3-4 3.3.1 Control word bits 3-4 3.3.2 State transitions 3-4 333 Mode-specitic bits 3.4 Status word 3-6 3.4.1 Status word bits ……3-6 3.4.2 State display 3-6 3.4.3 Mode Specific Bits 3.5 Profile velocity Mode ammaemntananananenas 3-8 3.6 Homing mode 3-9 3.7 Profile position mode 3-1 3.7.1 Set of Setpoints∴… .3-18 3.8 Table-supported positioning (manufacturer-spec )ma 3-20 3.8.1 Control word easy Drive-Table Pos 3-20 3.8.2 Status word Easy Drive-Table Pos 3-2 3.9 Speed control via fixed speeds (manufacturer-spec )mseammmesaaasassanaas 3-23 3.9.1 Control word easy Drive basic 3-23 3.9.2 Status word Easy Drive…….13-24 393 Speed control reference input 32Q16...3-25 3.94 Control word easy Drive basic 39.5 Status Easy Drive Basic 3-26 3.10 SS protocol 3-28 3.11 10 map object 60FDh amta 3-29 4 EDS file, object directory Appendix Index User Manual CM-CANopen LUST 1 General introduction 2 1.1 Commissioning…..1-2 1.1.1 Parameter setting 1.1.2 Parameter data types 1-2 1.13 Representation of data types 1.1.4 Commissioning via DRIVEMANAGER 143 1.1.5 Necessary parameter settings…… 1.1.6 Parameter set download 12 Hardware address coding mmmmmm mn 1-6 13 Hardware pin assignment maaamanmnnau. 1-6 14Baudratsm0174 1.5 Hardware enable n1-8 1.6 Implemented DS301 functionality n1-8 1.6.1 Communication objects 1-8 Object directory of 1.7.1 Addenda to DS301 object description 1.8 PDO mappIng n…aa1-12 1.8.1 Emergency object…... 1-15 1.8.2 Error acknowledgment via bus system 1-15 1.83 Other error acknowledgment options 1-16 1.8.4 Emergency error codes table .1-16 1.8.5 Heartbeat function 1-17 The CANOpen interface is implemented in accordance with communication profile DS301( Rev. 4.01) and device profile DS402( Rev2. 0 ) In the following EN sections more details are given of the degree of implementation of the FR profiles for CDE/B/F. T User Manual CM-Can2 L凵sT 1 General introduction This Manual is limited to a presentation of functionality in terms of the CANopen/field bus interface The general functional ity of the devices is presented in more detail in the relevant application manuals 1.1 Commissioning 1.1.1 Parameter The SDo standard is available for parameter setting via CANopen setting Manufacturer-specific parameters are addressed by way of object number 2000hex parameter number, paying attention to the data types of the individual parameters Settings are stored only in the device RAM, and are only stored permanently in the memory following triggering of a Save command The parameter values can be saved to the Flash/EEProm area by object 1010H (see 1.11 and. 1.12) and its subindices or by way of the DRIVEMANAGER commissioning tool 1.1.2 Parameter data types Note: By way of the dRIVEMANAGER user interface or the KeyPad KP200 control unit many parameter settings are displayed in the form of value substitution texts Example: Parameter 150-SAVE= STOP When writing and reading over the field bus the correspond values for these value substitution texts must be used. both in the application manuals of the devices and in this document, these values are given in brackets()after the value substitution Example: Parameter 152-ASTER= BUS_1(9 User manual cM-can2 1-2 LUST 1 General introduction The drive units support the following parameter data formats Data type Value range Function USiGN8 0..255 USIGN16 0..65535 Unsigned US|GN320…4294967295 int8 -128.127 INT16 32768..32767 2 2147483648 INT32 2147483647 NT32016 -32767993276699 32-bit number with scaling 1/65536, i.e. the Lo word indicates the number of decimal places FIXE 00..327680 Fixed point number with scaling 1/20 nt size 0.05 3 LoAT32see IEEE 32-bit floating point number in IEEE format ERR STRUC Error number(1 byte), error location(1 byte). error time(2 bytes) STRING ASCll characters, max. 100 bytes in bus operation incl. zero terminator 4 Table 1.1 Data types 1.1.3 Representation All data types are represented appropriate to their preceding sign as of data types 32-bit variables in Intel format Data byte of control protocol 6 A Low Word Low Word High Word High Word USIGN32/INT32 Low Byte High Byte LOW Byte High Byte INT32016 Post-pointL Post-point H Pre-point L Pre-point H FIXPOINT16 See examples IEEE format ERR STRUC Error no Error location TOP L TOP H STRING See examples Filled out appropriate to preceding sign(00H or FFH) TOP= Time of Operation in full hours L=Low Byte H=High Byte EN FR Table 1.2 Arrangement of data types in the data field T User Manual CM-CaN2 1-3 LUST 1 General introduction 1.1.4 Commissioning With the DRIVEMANAGER the desired preset solution can be selected, vIa paraI easily, DRIVEMANAGER commissioning. This also includes setting of the control mode. It is possible to switch control mode online. Initial commissioning is described the cde/CDB User manual If the initial commissioning settings given in the User Manual are not adequate for your application, you will find the further procedure in the CDE/CDB Application Manual 1.1.5 Necessary SDo access is always available, regardless of the device contiguration parametel The only important factors are the baud rate and device address settings settings The following default parameters should be changed as a minimum to enable data to be exchanged over CANopen using SDO Parameter Setting Function 580-COADR 1-127 CAn address 581-COBDR B500(2) an baud rate Table 1.3 Parameter change note: The parameter changes only take effect after a mains reset All parameters are stored only on triggering of the Save command in the dRIVemanager 1.1.6 Parameter set The following data can be transferred to the CDE/B/F3000 via the download CANopen interface Parameter set /PLC program A parameter data set or PLc program can be downloaded by a SDO transfer or by way of the drivemanager user interface version 3.2 or higher Important for SDo access: All manufacturer-specific device parameters are additionally accessible via objects 2000h-23ETh During downloading of a parameter data set the following sequence must be observed 1. Object 2050H SLOAD=-1(parameter plausibility check disabled) 2. Write data set to desired objects 2000H -23E7H by way of SDO access 3. Object 2050H SLOAD=-2 (data set checked by device) 4. Save all parameters via object 1010H User manual cM-can2 1-4
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: