 详细说明:TDK-Lambda CS150系列 单体式电源 抗扰性数据pdf,TDK-Lambda CS150系列 单体式电源 抗扰性数据CS150 1. Electrostatic Discharge Immunity Test(IEC61000-4-2) MODEL cS150-24 (1) Equipment Used Electro Static Discharge Simulator NSG435 (SCHAFFNER) Discharge Resistance 330Q2 Capacity 150pF (2) Test Conditions Input volt 230VAC Output Voltage Rated :100% Polarity Number of Tests 10 times Discharge Interval 1 se Ambient Temperture 25°C (3 Test Method and device test point Contact Discharge FG, Case Screw Air Discharge Input and Output TerminaL, FG, Case Screw Analog Voltage meter ElectroStaticDischarge Scintilator DL.T OAdI- Aluminiun Plato S OUTPUT AC INPUT Wood Made table GND Plane (4) Acceptable Conditions 1. Output voltage regulation not to exceed +5%of initial(before test )value during test 2. Output voltage to be within regulation specification after the test 3. Along with 1 and 2, no discharge of fire or smake, as wefl as no output failure (5) Test Result Contact discharge CS150-24 Air Discharge CS15024 (kV) 2 PASS 2 PASS SS PAS PASS 8 ASS TDK-Lambda R-1 CS150 Radiated Radio-Frequency Electromagnetic Field Immunity Test(IEC61000-4-3) MODEL cS150-24 (1) Equipment Used SML-03(RS CORPORATION) HL 046(RS CORPORATION) AR500W 1000A(AR CORPORATION) FM5004(AR CORPORATION) FP6001(AR CORPORATION) t condition Input volta 230VAC Output Voltage Rated Output Current 10% Amplitude modulated 80%,1kHz Electromagnetic Frequency 80-1000MHZ Ambient Temperature 25°C Distance :3.0m Wave Angle Horizontal and vertical Condition :1.0% Step Up, 2.8 Seconds Hold Test Angle Top/Bottom, Both Sides, Front/Back (3) Test Method D UT A:ll AC INPUT Wood Mace Table 0.8 △△ GND Plane Anechoic Material Reduce floor reflections (4) Acceptable Conditions 1. Output voltage regulation not to exceed #5%of initial (before test )value during test 2. Output voltage to be within regulation specification after the test 3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure (5) Test Result Radiation Field Strength(v/m) Cs15024 PASS PASS 10 PASS TDK-Lambda R-2 CS150 3. Electrical Fast Transient Burst Immunity Test(IEC61000-4-4) MODEL. CS150-24 Equipment Used EFT/B Generator FNS-1OOL NOISEKEN) (2 Test Condition roltage 230VAC Output voltage Rated g Output current 100% Test time 1 minute Polarity a Ambient temperature 25 Number of tests 3 times (3) Test Method and Device Test point Apply to(N, L, FG),(NL),(N),(),(FG) Aluminiun plate D U T AC INPUT GENERATOR Wood made able GND Plane (4) Acceptable Conditions 1.Output voltage regulation not to exceed #5%of initial (before test )value during test 2. Output voltage to be within output voltage regulation specification after the test 3. Along with 1 and 2, na discharge of fire or smoke, as well as no output failure (5) Test Result Normal mode Test Voltage Repetition Rate Cs150-24 (kv) 05 PASS 10 PASS 2.0 5 PASS TDK-Lambda R-3 CS150 4. Surge Immunity Test( IEC 61000-4-5) MODEL: CS150-244 (1) Equipment Uscd rge Generator NSGG51 ( SCHAFFNERY Coupling Impedance Common 12Q2 Coupling capacitance Common 9uF Normal 2Q Normal 18uF (2) Test Conditions nput Voltage 230VAC ● Output Voltage Rated Output Current 0%,100% Number of fests 5 times Polarity 十 de Common Normal ● Phase 90 deg ● Ambient Temperature:25°C (3) Test Method and Device Test Point Apply to Common mode( N-FG, L-FG)and Normal mode(N-L) Analog volle ge MeleT SURGE Aluminium plate GENERATOR D U.T LOAD AC INPUT 0. sn Wood Made table GND Plane Acceptable condition 1. Output voltage regulation not to exceed =5% of initial (before test )value during test 2. Output voltage to be within regulation specification after the test 3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure (5 Test Result est voltage(kV) Cs150-24 Test Voltage( kv) Cs150-24 Common Normal 0.5 PASS 0.5 PASS 10 PASS 1.0 PASS 2.0 PASS 2.0 PASS 4.0 PASS TDK-Lambda R-4 CS150 5. Conducted Disturbances Induced by Radio-Frequency Field Immunity Test(IEG61000-4-6) MODEL: CS150-24 (1) Equipment Used RF POWER AMPLIFIER (AR U.SA) SIGNAL GENERATOR IFR 2023A(FR U.K) (2) Test Conditions Input voltage 230VAC Output voltage Rated ● Output current 100% Electromagnetic Frequcncy 150kHz-80MHz Sweep Condition 1.0% Step Up, 2.8 Seconds Hold Ambient Temperature 25°C (3 Test Method Ana og voltag Aluninium Plata D UT RF INPUT < INPUT CDN 0.l GND Plane Wood Made 'Table (4) Acceptable Conditions 1. Output voltage regulation not to exceed +5% of initial (before test )value during test 2. Output voltage to be within regulation specification atter the test 3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure 5 Test Result e Level (V) CS150-24 PASS 3 PASS 10 PASS TDK-Lambda R-5 CS150 6. Power Frequency Magnetic Field Immunity Test (lEC61000-4-8 MODEL: CS150-24 (1) Equipment Used AC Power Source 1501L(California Instrument) Signal Phase Power Analyzer PM100( Voltech) Shunt Resister :2.592 Helmholts Coil HHS52 15 (Spulen (2) Test Conditions Input voltage 230VAC Output Voltage Rated Output current 100% Magnetic Frequency 50Hz e Test Time More than 10sec(Each direction) Direction YZ Ambient Temperature 25C (3) Test Method and Device Test Point Hell:olts Coi I D.U.I P LOAD Resistor Signal plasc analyzer AC INPUT Wcod Made table Souce (4) Acceptable Conditions 1. Output voltage regulation not to exceed 5% of initial (before test )value during test 2. Output voltage to be within regulation specification after the test 3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure (5 Test Result Magnctic Fieid Strength(A/m) CS150-24 PASS PASS PAS 30 PASS TDK-Lambda R-6 CS150 7. Voltage Dips, Short Interruptions Immunity Test (IEC61000-4-11) MODEL CS 150-24 (1) Equipment Used Tcst Generator: Chroma PROGRAMMABLE AC SOURCE MODEL 6530 2) Test Conditions Input Voltag 230VAC Output Voltage Output Current 100"o e Ambient t emperature 25°6 a Number of tests 3 times ● rest interval More than 1Osec (3) Test Method and Device Test Point Oscilloscope D,U: LOAD Wood Made'iable 0.8m AC INPUT TEST GENERATOR (4) Acceptable Conditions At test level 70% 1. Output voltage regulation not to exceed +5% of initial (before test )value during test 2. Output voltage to be within output voltage regulation specification after the test 3. Alang with 1 and 2, no discharge of fire or smoke, as well as no output failure At test level 40%.0% 1. Output voltage to be within output voltage regulation specification after the test No discharge of fire or smoke (5) Test Result Test level Dip rate Continue time Cs150-24 70% 10ms PASS 40% 60% 100ms PASS 0% 100% 5000ms PASS TDK-Lambda R-7
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: