文件名称:
TDK-Lambda CS150系列 单体式电源 抗扰性数据.pdf
开发工具:
文件大小: 304kb
下载次数: 0
上传时间: 2019-10-20
详细说明:TDK-Lambda CS150系列 单体式电源 抗扰性数据pdf,TDK-Lambda CS150系列 单体式电源 抗扰性数据CS150
1. Electrostatic Discharge Immunity Test(IEC61000-4-2)
MODEL
cS150-24
(1) Equipment Used
Electro Static Discharge Simulator
NSG435
(SCHAFFNER)
Discharge Resistance 330Q2
Capacity
150pF
(2) Test Conditions
Input volt
230VAC
Output Voltage
Rated
:100%
Polarity
Number of Tests
10 times
Discharge Interval
1 se
Ambient Temperture
25°C
(3 Test Method and device test point
Contact Discharge
FG, Case Screw
Air Discharge
Input and Output TerminaL, FG, Case Screw
Analog Voltage meter
ElectroStaticDischarge
Scintilator
DL.T
OAdI- Aluminiun Plato
S OUTPUT
AC INPUT
Wood Made table
GND Plane
(4) Acceptable Conditions
1. Output voltage regulation not to exceed +5%of initial(before test )value during test
2. Output voltage to be within regulation specification after the test
3. Along with 1 and 2, no discharge of fire or smake, as wefl as no output failure
(5) Test Result
Contact discharge
CS150-24
Air Discharge
CS15024
(kV)
2
PASS
2
PASS
SS
PAS
PASS
8
ASS
TDK-Lambda
R-1
CS150
Radiated Radio-Frequency Electromagnetic
Field Immunity Test(IEC61000-4-3)
MODEL
cS150-24
(1) Equipment Used
SML-03(RS CORPORATION)
HL 046(RS CORPORATION)
AR500W 1000A(AR CORPORATION)
FM5004(AR CORPORATION)
FP6001(AR CORPORATION)
t condition
Input volta
230VAC
Output Voltage
Rated
Output Current
10%
Amplitude modulated
80%,1kHz
Electromagnetic Frequency 80-1000MHZ
Ambient Temperature
25°C
Distance
:3.0m
Wave Angle
Horizontal and vertical
Condition
:1.0% Step Up, 2.8 Seconds Hold
Test Angle
Top/Bottom, Both Sides, Front/Back
(3) Test Method
D UT
A:ll
AC INPUT
Wood Mace Table
0.8
△△
GND Plane
Anechoic Material
Reduce floor reflections
(4) Acceptable Conditions
1. Output voltage regulation not to exceed #5%of initial (before test )value during test
2. Output voltage to be within regulation specification after the test
3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure
(5) Test Result
Radiation Field Strength(v/m)
Cs15024
PASS
PASS
10
PASS
TDK-Lambda
R-2
CS150
3. Electrical Fast Transient Burst Immunity Test(IEC61000-4-4)
MODEL. CS150-24
Equipment Used
EFT/B Generator FNS-1OOL NOISEKEN)
(2 Test Condition
roltage
230VAC
Output voltage
Rated
g Output current
100%
Test time
1 minute
Polarity
a Ambient temperature
25
Number of tests
3 times
(3) Test Method and Device Test point
Apply to(N, L, FG),(NL),(N),(),(FG)
Aluminiun plate
D U T
AC INPUT
GENERATOR
Wood made able
GND Plane
(4) Acceptable Conditions
1.Output voltage regulation not to exceed #5%of initial (before test )value during test
2. Output voltage to be within output voltage regulation specification after the test
3. Along with 1 and 2, na discharge of fire or smoke, as well as no output failure
(5) Test Result
Normal mode
Test Voltage
Repetition Rate
Cs150-24
(kv)
05
PASS
10
PASS
2.0
5
PASS
TDK-Lambda
R-3
CS150
4. Surge Immunity Test( IEC 61000-4-5)
MODEL: CS150-244
(1) Equipment Uscd
rge Generator
NSGG51 ( SCHAFFNERY
Coupling Impedance Common 12Q2
Coupling capacitance Common 9uF
Normal 2Q
Normal 18uF
(2) Test Conditions
nput Voltage
230VAC
● Output Voltage
Rated
Output Current
0%,100%
Number of fests
5 times
Polarity
十
de
Common Normal
● Phase
90 deg
● Ambient Temperature:25°C
(3) Test Method and Device Test Point
Apply to Common mode( N-FG, L-FG)and Normal mode(N-L)
Analog volle ge MeleT
SURGE
Aluminium plate
GENERATOR
D U.T
LOAD
AC INPUT
0. sn
Wood Made table
GND Plane
Acceptable condition
1. Output voltage regulation not to exceed =5% of initial (before test )value during test
2. Output voltage to be within regulation specification after the test
3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure
(5 Test Result
est voltage(kV)
Cs150-24
Test Voltage( kv)
Cs150-24
Common
Normal
0.5
PASS
0.5
PASS
10
PASS
1.0
PASS
2.0
PASS
2.0
PASS
4.0
PASS
TDK-Lambda
R-4
CS150
5. Conducted Disturbances Induced by Radio-Frequency
Field Immunity Test(IEG61000-4-6)
MODEL: CS150-24
(1) Equipment Used
RF POWER AMPLIFIER
(AR U.SA)
SIGNAL GENERATOR
IFR 2023A(FR U.K)
(2) Test Conditions
Input voltage
230VAC
Output voltage
Rated
● Output current
100%
Electromagnetic Frequcncy
150kHz-80MHz
Sweep Condition
1.0% Step Up, 2.8 Seconds Hold
Ambient Temperature
25°C
(3 Test Method
Ana og voltag
Aluninium Plata
D UT
RF INPUT
<
INPUT
CDN
0.l
GND Plane
Wood Made 'Table
(4) Acceptable Conditions
1. Output voltage regulation not to exceed +5% of initial (before test )value during test
2. Output voltage to be within regulation specification atter the test
3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure
5 Test Result
e Level (V)
CS150-24
PASS
3
PASS
10
PASS
TDK-Lambda
R-5
CS150
6. Power Frequency Magnetic Field Immunity Test (lEC61000-4-8
MODEL: CS150-24
(1) Equipment Used
AC Power Source
1501L(California Instrument)
Signal Phase Power Analyzer PM100( Voltech)
Shunt Resister
:2.592
Helmholts Coil
HHS52 15 (Spulen
(2) Test Conditions
Input voltage
230VAC
Output Voltage
Rated
Output current
100%
Magnetic Frequency 50Hz
e Test Time
More than 10sec(Each direction)
Direction
YZ
Ambient Temperature 25C
(3) Test Method and Device Test Point
Hell:olts Coi
I D.U.I
P LOAD
Resistor
Signal plasc
analyzer
AC INPUT
Wcod Made table
Souce
(4) Acceptable Conditions
1. Output voltage regulation not to exceed 5% of initial (before test )value during test
2. Output voltage to be within regulation specification after the test
3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure
(5 Test Result
Magnctic Fieid Strength(A/m)
CS150-24
PASS
PASS
PAS
30
PASS
TDK-Lambda
R-6
CS150
7. Voltage Dips, Short Interruptions Immunity Test (IEC61000-4-11)
MODEL CS 150-24
(1) Equipment Used
Tcst Generator: Chroma PROGRAMMABLE AC SOURCE MODEL 6530
2) Test Conditions
Input Voltag
230VAC
Output Voltage
Output Current 100"o
e Ambient t emperature
25°6
a Number of tests 3 times
● rest interval
More than 1Osec
(3) Test Method and Device Test Point
Oscilloscope
D,U:
LOAD
Wood Made'iable
0.8m
AC INPUT
TEST
GENERATOR
(4) Acceptable Conditions
At test level 70%
1. Output voltage regulation not to exceed +5% of initial (before test )value during test
2. Output voltage to be within output voltage regulation specification after the test
3. Alang with 1 and 2, no discharge of fire or smoke, as well as no output failure
At test level 40%.0%
1. Output voltage to be within output voltage regulation specification after the test
No discharge of fire or smoke
(5) Test Result
Test level
Dip rate
Continue time
Cs150-24
70%
10ms
PASS
40%
60%
100ms
PASS
0%
100%
5000ms
PASS
TDK-Lambda