详细说明:CitectSCADA5.5技术概要(英文版)pdf,CitectSCADA5.5技术概要(英文版)Contents
Profiles
Configuration
Citect Profile
Citect SCA DA Explorer
Cilec SCADA Profile
Graphics Builder…
36
Cicode editor Debut
untime
40
True Client-Server Architecture
Example project……
.42
System Architecture
iter Setup wizard
p
8 1/0 Device Communication
Large systems……
10 Puge Templates
.46
System Performance
/ RAD Graphics…
48
RAD Graphics……
2
Symbols
50
Internet clients
Multi-Language projects
Super genies
.51
eports
17 Common Tag Database
Trends
18 ActiveXTM Extensions
Alarms
20 Project Backup Restore
Networking……
Localized projects
Security
23 Localized CitectsCaDA
interfacing
Important
Remote 1/0 Device monitoring
26
ape
Data logging……
28 Cilect Customer service
56
Xy plots
28 Citect plant 2 business
SPC
29
Software Licensing
59
Comman& Controls…
30 Citect da features
Accumulators…
31 Glossary of Terms……
31 Supported 1/O Devices
Cicode
rofiles
〔 tect Profile
Microsoft
Independent International Innovative Resourceful
SOLUTION PROVIDER
Citect is a world leader in industrial automation software. The company
has offices in Australia, Africa, Europe, China, the usa and distributors
bb Citect is one of
in over 40 countries
the most technically
competent and
innovative Microsoft
Citect's goal is to provide ' best value
Citect's Industrial Information Management
Solution Developers
for money products and services
(IM) solutions enable manufacturers to
in Asia Pacific
The organization is focused on delivering
dramatically improve the performance of
and dominates its
value through technological excellence and
their production systems by targeting uptime,
market segment in
exceptional customer service and committed quality, throughput and other initiatives. B
to selective hiring, extensive training and
leveraging the CitectSCADA infrastructure,
region
99
building a culture that encourages innovation, much of the business information needed
Microsoft Australia, 1998.
excellence and service
to make informed decisions is collected
CitectSCADA, Citect's leading process
automatically, and seamlessly integrated with
software is renowned for its supcrior
the company's business systems
scalability, reliability and flexibility in
CitectIIM also provides Key Performance
applications across a broad range of
Indicators to business managers in real-
process industries
time, allowing fast, accurate decision-
Since its launch in 1992. citectscada
making to continuously improve efficiency
has been successfully applied in a number
and effectiveness
of interesting projects. Some of the more
Citect's integrated solutions enable
visible projects include Western Mining
manufacturers to transcend traditional
Corporations Olympic Dam Project, the
information sharing boundaries to
world's largest PC-based plant monitorin
dramatically enhance the quality of their
system, and monitoring of the facilities
plant management systems
operation at NASAs John F. Kennedy Space
Centre. There are currently over 60,000
icenses installed worldwide and users
include industry leaders such as BlIP. BMW.
Nestle, Baoshan Steel, Roche, samsung,
Pratt and Whitney, Alcoa, and Shell
66
By presenting plant information in useful and insightful formats that
allow companies to make well informed decisions, our products deliver a
high degree of value to a broad range of industries worldwide.
99
Colin Yamey, previously Strategic Development Director, Citect Pty Ltd.
Page 2
〔 items〔 ADA Profile
roles
Quality Flexible Scalable Reliable Open Fast
Industries
Aerospace, Agriculture
CitectSCADA is a leading industrial automation software system that
Aluminum, Automotive
enables users to reduce costs by optimizing plant operations. Based on
and aviation
true client server architecture, CitectSCADa provides maximum fexibility,
Beverage, Bio-Technology
proven reliability, quick installation and easy to manage functionality.
Building Management
(HVAC), Building
Materials and Security
Unique features like true dcs style
Cement Chemical
and coal
redundancy, scalability and valuable
packaging policies differentiate
Dairy and Defence
CitectsCADA from its competitors
Education
CitectSCADA systems are only sold one
Food
way-complete and ready to go All the
Glass
features, protocols and drivers are included,
Iron and steel
and because it's sold as one comprehensiv
Manufacturing, Marine,
package, it is tightly integrated and built
Mineral Processing
to perform.
nd mining
Nuclear
Unlike other pC-Based industrial control
systems, CitectSCADa was designed from
Oil and gas
its beginning to handle all the needs of
kaging, Petrochemicals,
large and complex enterprises in a single,
Pharmaceuticals
Pipelines, Plastics
integrated system while maintaining high
Power Distribution
performance and reliability
Generation and
The first CitectSCADA. installed in 1992
Transmission
established a new benchmark in pc based
Pulp and paper
SCADA SYStems that few vendors offer
Ship loading
even today-33,000 digital points, 16,000
Telecommunications
analog, 4,000 historical trends, 50 operator
Textiles, Traffi
stations, DCS style redundancy, single global
Management, Transport
database, configuration at any pc and a
Utilities
display update of under 2 seconds. Citect
Waste Water Water
clients enjoy the confidence that whethe
and Wood
their system is small or large, CitectSCADA
will do the job
By leveraging Microsofts talent, vision
and marketing leadership, Citect continues
to lower the cost of acquiring, deploying
and managing large-scale industrial control
systems. It enables plant managers to
seamlessly link plant level information to
business planning systems and through
the internet. to remote users devices
and suppliers
Page 3
Runtime
True Cient Server architecture
A file server acts merely
Ouality Flexible scalable reliable open Fast
as a central file storage
area, distributing
Designed-from the start-for true client-server architecture,
unprocessed data upon
request from the client
CitectsCADA is the real-time system that ensures high performance
The client then processes
response and integrity of data.
and filters the data
ocally, creating a lot
of unnecessary network
traffic. With client-server
To take full advantage of a client-server architecture, it must be utilized at the task level
architecture, however,
Each task works as a distinct client and/or server module, performing its own role, and
most data management
interfacing with the other tasks through the client-server relationship. CitectsCADa has fiv
and processing Ls
performed by the server.
fundamental tasks which handle: communications with I/O Devices: monitoring of alarm
The client is, therefore
conditions; report type output; trending; and user display
ble to request very
specific information
This means that only
smaller puckets or clean
Display dient
Display Client
data are sent across the
network, thus reducir
Server
network load.
CitectSCADA's Virtual
10 Server
Data Network(DN
provides the foundation
for a robust client-server
architecture
V0 Devices
1/0 Devices
The 1/0 task is responsible for all
If a display is shown, the display task
communications with the I/o Devices
client)requests the specific data from the
on behalf of the other tasks the l o task
1/O task(server) The lO Server gathers
functions as a server to the other task
and sorts the raw data and responds to the
(which are its clients)
Display client with only the requested data
Display Client
Alurm server
Display Client
Alarm Server
DN
10 Server
Trend Server
The Alarms Server gathers and sorts the raw
1/0 Devices
alarm data rcqucstcd from the l/O Sc
If an alarm list is shown the display client
The Trends and Reports servers work
requests the specific alarm data from the
in the same way as the l/ o server and
Alarms server
Alarms Server, providing processed data to
Runtime
The Reports server is actually a client to the trends and alarms servers when trend and alarm
One of the most impor-
data is included in a report. when a report runs the reports client requests the necessary data
tant factors in building a
from the appropriate server
fast, efficient client-server
application is minimizing
the amount of data pulle
down from the
As data volume increases
the advantages of cli
server architecture
Because servers are designed to
become more and
Display Client
isplay Client
support multiple clients, adding
Alarm server
a new display cl
Report Server
At a glance
few mouse clicks on the new pc
Trend serve
without interfering with the existing
口 Client- Server
system. Both Display Clients get
distributed processing
their information from the
a Data integrity
Server The vdn is now effectivel
口 High efficiency
extended across the lan- with no
口 Functional(task-
loss of functionality
based) architecture
口 Nerwork
If secondary servers are
available, the architecture supports
Alarm server
Alarm Server
redundancy. For example, if we
dd a redundant Alarms server
Trend Server
the standby is ready to fill in for
1/0 Server
the primary server if it fails
Redundant server
Even if all tasks are divided into separate PCs connected by a LAN, the client-server relationship
emains the same true client-server architecture
LAN
Report Server
Trend Server
VDN
Trend Server
VDN
1/0 Server
rgrh
1/0 Devices
Page 5
Runtime
System Architecture
Centralized processing
Ouality Flexible scalable Reliable open Fast
has the benefit that you
can keep all data, and do
Your SCaDA syStem has unique requirements that change with time, so
all processing, in one spot
Distributed processing, on
how can you choose the best architecture? Citectscada gives you the
the other hand. allows
ultimate system architecture: flexible and scalable
sharing of the workload
over multiple computers
CitectSCADA lets you
take advantage of both
Flexible architecture
technologies
Flexibility is the power to arrange your system architecture in a variety of ways. Rather than
locking you into one method, CitectSCADA allows to choose your own system architecture
giving you the best features of both centralized and distributed processing
Designed from the start for client-Server architecture, CitectSCADa is functionally divided into
five separate tasks
Manages, and optimizes all communications
Alarms Monitors all alarm conditions: analog, digital, and SPC
Reports Controls, schedules, and executes report operations
Trends Collects, records, and manages trend and spc data
Display Thc Human Machinc Intcrfacc(HMI). It interfaces with the othcr tasks to
maintain the display -refreshing screen data, and executing commands
Each of these tasks is independent
Display Client
pcrforming its own proccssing. Duc to this
unique architecture, you have control over
which computers in your system perform
Trends
Reports
which tasks. For example, you can nominate
Server
Ser
one computer to perform the display, and
report tasks, while your second computer
performs display, I/O, and trends
1/0 Server
CitectSCADA encourages you to use a
Client Response
erver Response
centralized database when using networked
systems. Having one global database is
bviously beneficial, since you only make
changes at one location-which are then
dated cvcrywhcrc. Of co
want to use separate configurations on each
computer, you can do that too. You can even
Display Client Display Client Display Client
File ser
have a mixture of both
While citectSCada has a reputation
1/0
for installations involving nctworks and
Alarm server‖ rend server
Report server
large amounts of data, many users have
single CitectsCADa installations Using
CitectSCADA, your system can start out
as simple as you like and grow as large
as required
vices
Page 6
Runtime
Scalable architecture
For in-depth information
on using Scalable
Scalability is the power to resize your system-up or down- without having to modify any
Architecture in plant
of the existing system hardware or software CitectSCADA's innovative Scalable architecture
control ana monttoring
allows your systems architecture to grow with your requirements, while preserving your
systems, contact your
initial investment
distributor and ask for
the scalable architecture
CitectsCADA makes the most of its task oriented client-server design, allowing you to re-
technical paper
locate tasks as you add more CitectSCADA computers. For example, if you require a second
All network setup is done
HMI, just add a LAN and a new computer, and nominate it as a Display client. The new
automatically by a wizard
computer can share the same configuration, and will receive 1O from the first CitectsCADa
a new CitectSCADA
computer can be up
A secondary benefit of doing this is that you can also distribute the processing load. For
and running in minutes,
example, if you think your first CitectSCADA computer is too busy, you can simply nominate
without the need to shut
the second to take care of the alarms by becoming the Alarms server
anything down
At a gla
口 Flexible
口 Scalable( resizable)
without shutting down
Centralized
Put simply, some users want simple HMI
Display re
Distributed
while others want a complete SCaDa
system. With CitectSCADA, you can do both
Start small
Display client
len
ay
Display Client
Display Client
Citect server
(Reports, Trends,
and grow bigger- without
new stations, just install the new
omputer, and nominate the task
(or tasks)it should perform
Page 7
Runtime
redundancy
The developers of
Ouality Flexible scalable Reliable open Fast
CitectSCADA understand
that" A chain is only as
In factory automation and other mission critical applicationS, hardware
strong as Its weakest
link. For that reason, th
failure leads to production loss, and can result in potentially hazardous
redundancy features of
situationS. CitectSCADA's redundancy will tolerate failure anywhere in
CitectsCADa are truly
yoursystem, with no loss of functionality, or performance
comprehenSive, guarding
all areas where failure
mav occul
CitectSCADa supports full hot standb
Primary l/0 Server
CitectSCADA s
nfigurations, providing complete 1/0
redundancy features
Device redundancy By nominating one
ure tightly integrated
device as primary, and the other as standby
into the alarm system
CitectSCADA will automatically switch from
Primary Data Path Standby Dulu Path
When a failure occurs
CitectSCADA will notif
one to the other in the event of failure. Using
the operator which piece
CitectSCADA'S ability to write setpoint
ofequipment has failed
hanges to both primary and standby l/o
and which redundant
Devices. even 1/0 Devices that were not
equipment has taken over:
designed for redundancy can be used in a
Primary 1/0 Device Standby 1/0 Device
redundant configuration
a broken communication cable and
unpredictable electrical noise are common
Server
communication problems. In response
itectSCADA allows the use of two separate
communication cables(run separately)
-n Primary Data Path
for cach 1O Device. By using data path
Standby data Path
redundancy, you minimize the chance of
communication loss affecting your operation
When communicating with an IO Device
many systems demand redundant 1/O Server
configurations. To avoid conflict of data. and
0 Device
to maximize communication bandwidth, only
the primary 1/O Server communicates with
the l/o device
Many scada systems use Lans to
ct the elements, but something
simple as a faulty network card can destroy
communication. CitectSCADA's built-in
multiple network support provides Full
LAN Redundancy. all you have to de
install two networks (or more if you like). If
Display Client Display Client Display Client Display Client
LAN 1
the primary lan fails, CitectSCADA will
LAN 2
automatically try to connect on the other
available LA Ns- no configuration required
ary Server
Standby Server
arm server
Trend St
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.