您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 博世 FRay5000-50-EN Linear Smoke Detector 用户使用说明书.pdf
  所属分类: 其它
  开发工具:
  文件大小: 682kb
  下载次数: 0
  上传时间: 2019-10-19
  提 供 者: weixin_********
 详细说明:博世 FRay5000-50-EN Linear Smoke Detector 用户使用说明书pdf,博世 FRay5000-50-EN Linear Smoke Detector 用户使用说明书Contents Installation General information Fitting the Product Wiring Diagrams Commissioning Apply power and Enter Pass Code Select power mode and distance 9 LASER Targeting Auto Alignment and 'set0/100(Calibrate) In use Settings and Final Tests 12 Cleaning Manual fire and fault tests Troubleshooting Error codes 14 LASER Not∨isib|e Home position System Information LCD Icon Layout Status Indicators 18 User Menu Layout 20 Engineering Menu Layout 21 Detector Settings Menu Layout System Controller Settings Menu Layout Operating Parameters and Dimensions 24 Approvals and Territory Specific Information Installation General Information -- 50-100m=x4 50cm 圈 18-50m=X1 50cm 图8-18m 8-100m Use Short Range Mask Ensure clear line of sight Mount on solid surfaces(structural wall or girder) from detector to reflector Check the beam spacing against local regulations Position beam as high as possible, but with a minimum distance of 0.5m from detector to ceiling Mount detector and reflector directly opposite each other Do NOT position detector where personnel or objects can enter the beam path 4 Installation Fitting the Product Options for Detector wiring orientation LED indicator must face downward Installation Wiring Diagrams TO THE TO THE DETECTOR DETECTOR “→++++“+ DET 1 14V-28V DC DET 1 14-28DG Ext Reset FAULT FAULT ··· Con A Cn日 标标标标标 Cn為 Con B 123 N。cMNc N。|cMNc N'OCOMNiC NO COM NiC Apply a voltage of 5v to 40V to'Ext Reset contact to clear ReS S10 Latched Fire condition ZONE EOL ZONE SUPPLY SUPPLY EARTHISCREEN Wiring for all other beams(multi-beam systems)..,.Wiring for single or last beam on a zone *Fire Resistor- Contact fire Control panel ALWAYS use a separate screened 2-core cable manufacturer for values of fire resistor for each detector head Some zone and switch Interface modules do not End Of Line(EOL )component is need a Fire Resistor - replace Resistor with a short supplied by Fire Control Panel manufacturer circuit. Refer to supplied CD for further information Check operation of Fire and Fault connection on 6 Fire Pane Commissioning Apply Power and Enter Pass Code 1. Apply power 2. Enter Pass Code to Access Engineering Menu A888日 Press for Pass Code screen 回回国国回回國国 2 seconds c00=日 E-0i 40 seconds Default pass code:1 4 Change digit 几D Move between digits √ Accept An incorrect Pass Code will return the display to the Pass Code entry screen Three incorrect attempts will lock access for three inutes 几[p Note-a commissioned system will display Commissioning Select Power Mode and distance 3. Select Power mode 4. Select distance between Detector and reflector All functions can be performed in Lo A(10mA) Select 8-50m(default)or 100m mode(default Select Hi a(50mA) to enable faster beam movement during Auto-Align and Laser Targeting After installation, set the system back to Lo A H只 几 g-52 卢B*份上辔B 回 由上ap 回 < Use((> to move between 4. Use icons in the Engineering menu change selection to highlight the icon shown 5. Press to accept 2. Press to select Press to cancel 3. Use(( to move to required item Menu Navigation Commissioning LASER Targeting 5. LASER Targeting The system will signal Fault while in this mode The LASER is used to align the detector with the reflector c00E日 is an approximate alignment tool only After Auto-Align the LASER may not be aimed directly at the Reflector Use<>Av to move the LaSeR as close to the Reflector as possible One press of an arrow key results in one movement of the detector head Press v or x to turn off the LASER and return to the Settings menu Refer to User Guide page 14 for troubleshooting if LASER DANGER is not visible LASER RAD|AToN·AVo|D DIRECT EYE EXPOSURE POWER OUTPUT 5mw Wavelength 630-680 nm 9 Commissioning Auto Alignment and Set0/100 (Calibrate 6. 'Auto Alignment 7. 'Set0/100(Calibrate) 5-2 < 5-90 H 》 回|由③量2 SEL 上日圳圈}选感a 回 < When 'Set is displayed press 36 When'S-00' is displayed, cover the Reflector with a non reflective material and leave covered, then press v Select 'Auto to automatically When 'S-01 is displayed, uncover the Reflector and align the infrared beam leave uncovered, then press v Signal Strength will be shown LOA:18 minutes during Alignment HiA:15 minutes 8. System is Aligned It is recommended to set the system back to Lo A mode SEt Green LED on Detector will flash every 10 seconds, and Signal Strength should be between 99% and 101% Default values: 35% Fire Threshold, 10 second delay to Fire and Fault, Non-Latching mode Refer to User Guide page 11-12 to change settings and for fire and fault Test 10
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: