您好,欢迎光临本网站![请登录][注册会员]  
文件名称: CP 441 Manual.pdf
  所属分类: 其它
  开发工具:
  文件大小: 1mb
  下载次数: 0
  上传时间: 2019-10-19
  提 供 者: weixin_********
 详细说明:CP 441 Manualpdf,CP 441 ManualPreface Purpose This manual explains how to establish and operate a point-to-point connection Contents of this manua The manual describes the hardware and software of the cp 44 1 communication processor and its integration in an S7-400 programmable controller. It is divided up into instruction-based chapters and a reference section(appendices) The following subjects are covered on The basics of point-to-point communication with the CP 441 oo Starting up the CP 441 oo mounting the cp 44 1 oo Communication via the cP 44 1 oo Debugging oo Application examples oo Properties and technical specifications Scope of This Manual The manual is relevant to the following CPs and interface submodules Product Order number As of release CP441-1 6ES74411AA03-0AE0 01 CP441-2 6ES7441-2AA030AE0 01 RS 232C module 6ES7963-1AA000AA0 01 20 mA TTY module 6ES79632AA000AA0 01 X27(RS 422/485)module 6ES7 963-3AA00-0AAO 01 Point-to-Point Communication CP 441 C79000-G7076-c441-05 Preface Note The descriptions of the cp 44 1 communication processor and the interface submodules in this manual were correct at the time of publication We reserve the right to describe modifications to the functionality of the modules in a separate Product Information Changes since the Previous edition Changes Since the Previous Edition Since edition 02 of this manual, CP 441 Point-to-Point Communication, Installation and Parameter Assignment descriptions of the following functions of the cp 441 with order number 6ES7441-AA03-OAEO have been added o additional transfer rates of 5 6 kbaud and 115.2 kbaud for the cp 441-2 from STEP7.V5.0+ Service Pack 2 onwards oo Dynamically changeable destinations in RK512 send message frames oo Firmware update oo Diagnostics alarm from STEP 7, V5.0+ Service Pack 2 onwards on Fast switch-over for RS485 module in half-duplex mode RS422 485 level selection now for 3964(R), RK512 and printer oo Extended modes for reception with end-of-text codes oo Shorter character delay time at low baud rates oo ASCll protocol with fixed message frame length sending in character delay time matrix can be deactivated Conventions This manual uses the generic term CP 441. The information in the manual applies to the CP 1-1 and CP 4411-2 communication processors, unless otherwise specified Structure of this manual To help you to quickly find the information you require, this manual offers the following oo a comprehensive list of contents oo Following the appendices, a glossary defines important technical terms used in the manual oo Finally, a comprehensive index allows quick access to information on specific subjects Point-to-Point Communication CP 441 C79000-G7076-C441-05 Preface Other Manuals required The appendix F contains a list of further manuals and brochures on the S7-400 and programmable controllers Electronic manuals The entire set of simatic s7 documentation is available on cd-rom Standards, Certificates and Approvals The CP 44 1 communication processor meets the requirements and criteria of lEC 1131, Part 2 and the requirements for CE marking. The CP 441 has CSA certification and uL recognition You will find more information on certification/recognition/approval and standards in Appendix A2 Recycling and Disposal The CP 441 is an environment-friendly product. It is exceptional for the following oo Housing plastic with halogen-free flame protection and is highly resistant to fire oo Laser inscriptions(.e no labels) oo Plastics identification in accordance with din 54840 oo Fewer materials used due to size reduction; fewer parts due to integration in ASICs The cp 44 1 is suitable for recycling on account of the low level of contaminants in Its components For further information about environment-friendly recycling and the procedure for disposing of your old equipment, please contact Siemens Aktiengesellschaft Anlagenbau und Technische Dienstleistungen ATD ERC Essen Recycling/Remarketing Fronthauser str, 69 D-45127 Essen Germany Phone:+ 49 201/816 1540(Hotline) FaX:+49201/8161504 The people there will adapt their advice to suit your situation and provide a comprehensive and flexible recycling and disposal system at a fixed price. After disposal you will receive information giving you a breakdown of the relevant material fractions and the associated documents as evidence of the materials olved Point-to-Point Communication CP 441 C79000-G7076-C441-05 Preface Additional Assistance Please contact your local siemens representative if you have any queries about the products described in this manual. a list of Siemens representatives worldwide is contained, for example, in the appendix entitled Siemens Worldwide" of the manual S7-400/M7-400 Programmable Controller, Hardware and Installation If you have any questions or suggestions concerning this manual, please fill out the form at the back and return it to the specified address Please feel free to enter your personal assessment of the manual in the form provided We offer a range of courses to help get you started with the SIMATIC S7 programmable controller. Please contact your local training center or the central training center in Nuremberg, D-90027 Germany, Tel. +49 911 895 3200 Point-to-Point communication cp 441 C79000-G7076-C441-05 Preface Up to the minute You can obtain the latest information on SIMATIC products from the Information following sources ooontheInternetathttp:/www.ad.siemens.de, SIMATIC Customer Support also provides you with the latest information and downloads that will help you use SIMATIC products ooontheiNternetathttp://www.ad.siemens.de/simatic-cs oo From the SiMATIC Customer Support Mailbox at the number +49(911)895-7100 To dial the mailbox, use a modem with up to v.34(28. 8 kbauds), with the following parameter settings: 8, N,1, ANSI, or dial via ISDN(X.75, 64 Kbps) SIMATIC Customer Support is available at the phone and fax numbers and at the E-mail addresses listed below you can also contact us via internet mail or mail at the mailbox mentioned above Nuremberg Johnson City a& Singapore SIMATIC Hotline Worldwide(Nuremberg) Worldwide(Nuremberg) Technical Support Technical Support (Free Contact) (fee based, only with Local time: Mon-fri.7: 00 to 17: 00 SIMATIC Card Phone:+49(180)5050-222 +49(180)5050-223 Local time: mon -fri. 0: 00 to 24: 00 E-Mail: techsupport Phone:+49(911)895777 ad siemens. de FaX:+49(911)8957001 GMT +1:00 GMT +01:00 Europe /Africa(Nuremberg) America Johnson City) Asia Australia( Singapore) Authorization Technical Support and Technical Support and Authorization Authorization Local time: mon -fri.7: 00 to 17: 00 Local time: Mon -fri. 8: 00 to 19: 00 Local time: Mon. -fri. 8: 30 to 17: 30 Phone:+49(911)8957200 Phone:+1423461-2522 Phone:+65740-7000 Fax:+49(911)895-7201 Fax:+14234612289 +65740-7001 E-Mail: authorization E-Mail: simatic hotline E-Mail: simatic hotline bgm. siemens. de sea. sIemens. com sae.slemens.com.sg GMT:+1:00 GMT 5:00 GMT 8:00 The languages of the SIMATIC Hotlines are generally German and English, in addition, French, Italian and spanish are spoken on the authorization hotline Point-to-Point Communication CP 441 C79000-G7076-C441-05 Point-to-Point communication cp 441 C79000-G7076-C441-05 Contents 1 Product Description B重 1-1 1.1 Uses of the cp 441 1-2 1.2 Components Required for a Point-to-Point Connection with the CP441.1-4 3 Design of the CP 441 16 1.4 Attributes of the interface submodules 1-8 1.4.1 Attributes of the rs 232c interface Submodule 1-8 1.4.2 Attributes of the 20 ma tty Interface submodule -10 1.4. 3 Attributes of the X27(RS 422/485)Interface Submodule 1-11 1.4.4 Cables for Connecting the CP 44 1 to a Communication Partner 1-12 1.5 Installation guidelines -13 2 Basic Principles of Serial Data Transmission 21 2.1 Serial transmission of a character 2-2 2.2 Transmission procedure with a point-to-Point connection 6 2.2.1 so 7-Layer Reference Model for Data Transmission 26 2.2.2 Data Transmission with the 3964(R)Procedure 2-12 2.2.3 Data Transmission with the rK 512 Computer Connection 225 2.24 Data transmission with the ascll driver 2-37 2.2.5 Data transmission with the printer driver 2-51 2.3 Parameterization Data of the protocols 翻 2-53 2.3.1 Parameterization Data of the 3964(R)Procedure 253 2.3.2 Parameterization data of the rK 512 Computer Connection 259 2.3.3 Parameterization data of the ascll driver 2-60 2.3.4 Parameterization data of the printer driver 2-67 2.3.5 Conversion and Control statements for Printer Output 2-78 3 Starting up the CP 441 3-1 4 Mounting the CP 441 4-1 4.1 CP 441 Slots 42 4.2 Mounting and Dismounting the CP 441 42 4.3 Installing and Removing the Interface Submodules of the CP 44 1 4-3 Point-to-Point Communication CP 441 C79000-G7076-c441-05 Contents 5 Configuring and Parameterizing the CP 441 5-1 5.1 Configuring the CP 441 5-2 5.2 Parameterizing the communication Protocols 5-3 5.3 Connection Configuration 5.3.1 Simplified Connection Configuration 55 5.3.2 Complete Connection Configuration 5.3.3 "Object Properties"Dialog Box for the ASCll Driver, Printer Driver and 3964(R)Procedure 5.3. 4 "Object Properties"Dialog Box for the RK 512 Computer Connection. ..5-12 5.4 Managing the Parameter Data 5-16 5.5 Multiprocessor Communication 5.6 Subsequent Loading of Drivers (transmission Protocols) 5-18 Subsequent Loading of Firmware Updates 5-20 6 Communication via System Function Blocks...............6 Communication via System Function blocks 6-2 6.2 Overview of the System Function Blocks 6-3 6.3 Using the System Function Blocks 6-4 Using the System Function Blocks with the 3964(R)Procedure 6-10 6.4.1 Data Transmission with 3964(R)Using BSEND and BRCV 6-12 6.4.2 Data Transmission with 3964(R)Using bSENd and a receive Mailbox.6-15 6.5 Using the System Function Blocks with the RK 512 Computer Connection 6-17 6.5.1 Send data with a static destination definition with rK 512 6-17 6.5.2 Sending Data with RK 512 to the Communication Partner CP 441 with Static Destination definition Use of bsend and brcv 6-19 6.5.3 Sending Data with RK 512 to the Communication Partner CP 441 with Static Destination Definition Use of bsend 24 6.5.4 Sending Data with rK 512 to the S5 Communication Partner or non -siemens device with static Destination definition 6-29 6.5.5 Sending data to a communication partner with dynamic Destination Definition with the rK 512 Computer link 6-35 6.5.6 Fetching Data from a communication Partner with rK 512 6-40 6.6 Using the System Function Blocks with the ASCll Driver 6-45 Using the System Function Blocks with the printer driver 6-51 6.8 Summary 6-54 7 Start-up Characteristics and Operating Mode Transitions of the CP 441....7-1 7.1 Start-up Characteristics of the CP 441 72 7.2 Operating Mode Transitions of the CP 441 73 Point-to-Point Communication CP 441 C79000-G7076-c441-05
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 相关搜索: CP441Manual.pdf
 输入关键字,在本站1000多万海量源码库中尽情搜索: