详细说明:CP 440 Manualpdf,CP 440 ManualPreface
Purpose
This manual explains how to establish and operate a point-to-point connection
Contents of this manua
The manual describes the hardware and software of the cp 440 communication
processor and its integration in an S7-400 programmable controller. It is divided up
into instruction-based chapters and a reference section(appendices)
The following subjects are covered
on The basics of point-to-point communication with the CP 440
oo Starting up the CP 440
oo Installing the cp 440
oo Communication with the cp 440
oo Troubleshooting
oo Application examples
oo Properties and technical specifications
Scope of This Manual
This manual is valid for the following
Product
Order number
As of version
CP 440 with the
6Es7440-1Cs00-0YE0
01
X27 RS 422/485 interface
The description of the cp 440 communication processor in this manual were
correct at the time of publication We reserve the right to describe modifications to
the functionality of the modules in a separate Product Information
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02
Preface
Structure of this manual
To help you to quickly find the information you require, this manual offers the
followIng
oo You will find a full table of contents at the beginning of the manual
oo Finally, a comprehensive index allows quick access to information on specific
subjects
Point-to-point connection CP 440 Installation and Parameter assignment
A5E00057742-02
Preface
Other Manuals required
Appendix E contains a list of the other manuals on the subject of the s7-400 that
you will require in order to put your system into operation
Electronic manuals
The entire set of simatic s7 documentation is available on cd-rom
Standards, Certificates and Approvals
The CP 440 communication processor meets the requirements and criteria of
EC 1131, Part 2 and the requirements for ce marking The cp 440 has CSa
certification, UL recognition and FM approval
Recycling and Disposal
The CP 440 is an environment-friendly product. It is exceptional for the following
oo Housing plastic with halogen- free flame protection and is highly resistant to fire
oo Laser inscriptions(i.e. no labels
oo plastics identification in accordance with din 54840
oo Fewer materials used due to size reduction; fewer parts due to integration in
ASICs
The Cp 440 is suitable for recycling on account of the low level of contaminants in
its components
For further information about environment-friendly recycling and the procedure for
disposing of your old equipment, please contact
Siemens Aktiengesellschaft
Anlagenbau und Technische Dienstleistungen
Atd tD 3 Kreislaufwirtschaft
Postfach 32 40
D-91050 Erlangen, Germany
Phone:+499131/7-33698
FaX:+499131/7-26643
The people there will adapt their advice to suit your situation and provide a
comprehensive and flexible recycling and disposal system at a fixed price. After
disposal you will receive information giving you a breakdown of the relevant
material fractions and the associated documents as evidence of the materials
involved
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02
Preface
Additional Assistance
Please contact your local siemens representative if you have any queries about
the products described in this manual. a list of Siemens representatives worldwide
is contained, for example, in the "Siemens Worldwide" Appendix of the manual
S7-400 Programmable Controller, Hardware and Installation
If you have any questions or suggestions concerning this manual, please fill out the
form at the back and return it to the specified address Please feel free to enter
your personal assessment of the manual in the form provided
We offer a range of courses to help get you started with the SIMATIC S7
programmable controller. Please contact your local training center or the central
training center in Nuremberg, D-90027 Germany(tel +49 911 895 3200)
Constantly Updated Information
You can obtain constantly updated information on the siMAtiC products on the
Internetathttp://www.ad.siemens.de
In addition, SIMATIC Customer Support provides you with up-to-date information
and downloads that can be useful to you when using SIMATIC products
ooontheInternetathttp://www.ad.siemens.de/simatic-cs
oo Via the SIMATIC Customer Support Mailbox(German) at +49(911)895-7100
or the SIMATIC Customer Support BBS (English)
The mailbox is best accessed with a modem up to V.34(28. 8 kbps)parameterized
as follows: 8, N, 1, ANSI, or via ISDN (X. 75, 64 kbits
You can contact SIMATIC Customer Support by phone at +49 (911)895-7000 or
by fax at +49(911)895-7002. You can send questions by e- mail on the Internet or
to the above-mentioned mailbox
Point-to-point connection CP 440 Installation and Parameter assignment
A5E00057742-02
Contents
1 Product Description
1.1
Applications of the CP 440
1-2
1.2
Components Required for a point-to-Point Connection with the CP 440
1-3
1.3
Design of the CP440
1-6
1.4
Features of the X27(Rs 422/485)Interface
8
1.4. 1 Cables for Connecting the cp 440 to a communication Partner
2 Basic Principles of Serial Data Transmission
2
2.1
Serial transmission of a character
2-2
2.2
Transmission procedure with a point-to-Point connection
26
2.2.
iso 7-Layer Reference Model for Data Transmission
26
2.2 Data transmission with the ascll driver
211
2.2.3 Data Transmission with the 3964(R)Procedure
2-24
3 Commissioning the CP 440......
3.1
Sequence of Steps to Be Taken
3-2
3.2
Commissioning the physical Interface
3-4
Installing the CP 440
4-1
4.1
CP 440 Slots
4-2
4.2
Installing and Removing the CP 440
4-3
4.3
Installation Guidelines
4-4
5 Configuring and Parameterizing the CP 440
5-1
5.1
Configuring the CP 440
5-2
5.2
Parameterizing the Communication Protocols
-3
5.3
Parameterization data
5.3.1 Basic Parameters of the cp 440
5-4
5.3.2 Parameterization Data of the ascll driver
5-6
5.3.3 Parameterization Data of the 3964(R)Procedure
5-14
5.4
Management of the Parameter Data
5-20
5.5
Uploading Firmware Updates
5-21
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02
Contents
6 Communication Using Function Blocks
6-1
6.1
Communication Using function blocks
62
6.2
Overview of the function blocks
6
6.3
Notes on Program structure
64
6.4
Using the Function blocks
6.41 The s7 transmits data to a communication partner
10 SEND 440 FB
6-6
6.42 S7 Receives data from a communication partner 9 RECV 440 FB
6-10
6.4.3 Deleting the Receive Buffer(11 RES RECV FB)
6-14
6.5
Programming the Function Blocks
6-18
6.5.1 General Information on Data Block Assignment
6-18
6.5.2 Supplying the block Parameters
6-19
6.6
General Information on Program Processing
6-23
6.7
Technical Specifications of the Function Blocks
6-24
7 Startup Characteristics and Operating Mode Transitions of the CP 440
7.1
Operating Modes of the CP 440
7.2
Startup Characteristics of the cp 440
7-2
7.3
Behavior of the CP 440 During Operating Mode Transitions of the CPU
7.4
Behavior of the sender line drivers of the serial interface
During Particular Operating Modes of the CP 440
7-4
8 Diagnostics with the cp 440
8-1
8.1
Diagnostic functions of the CP 440
8-2
8.2 Diagnosis via the Display Elements of the CP 440
8-3
8.3
Diagnostic Messages of the Function Blocks
8-5
8.4 Diagnostics Using the Diagnostic Buffer of the CP440........8-14
9 Programming Example- Standard Blocks
■■■
9-1
9.1
General
9-2
9.2
Device Configuration
9-2
9.3
Settings
9-3
94
Blocks Used
9-4
9.5
Installation, Error Message
9-7
9.6
Activation, Startup Program and Cyclic Program
98
9.6.1 CP440 SEND RECV Program Example
9-8
96.2“CP4401cYc” Program Example
9-9
9.6.3"CP440 ASCll BCC Program EXample
9-10
9.64“CP440 MASTER” Program Example.
9-12
9.6.5“CP440 SLAVE” Program Example.
9-12
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02
Contents
A Technical Specifications
A-1
A.1
Technical specifications of the cp 440
A
A.2
Transmissⅰ on times
A
25
B Connecting Cables.∴
B-1
B.1
X27(RS 422 /485)Interface of the CP 440
B-2
c Communication matrix of the protocols
C-1
d Accessories and order numbers
E Reference for sIMATIC s7
E
Index
Index.
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.