详细说明:森兰变频\SB6061-2pdf,森兰变频\SB6061-25 TABLE OF FUNCTIONS……
5.1 Description
5.2 Table of functions
6 FUNCTION DETAILS
6. 1 Function group F0: basic function...
6.2 Function group F1: V/F control
6-9
6.3 Function group F2: vector control
6-18
6.4 Function group F3: analog setting
……6-20
6.5 Function group F4: auxiliary function
6-22
66 Function group F5: terminal function……
6-28
6.7 Function group F6: auxiliary frequency function…………6-39
6.8 Function group F7: simple PlC function
…6-45
6.9 Function group F8: process PID function
6-50
6.10 Function group F9: communication parameters……………6-58
6. 11 Function group FA: display function
…6-60
6. 12 Function group Fb: factory function
6-63
6.13 Function group Fc: computer display function
…6-64
7 MAINTENANCE
7-1
7.1 Daily inspection maintenance
7-2
7.2 Periodical maintenance………………
…7-2
7.3 Insulation test
7-3
7.4 Replacement of parts
7-4
8 TROUBLESHOOTING
8-1
8.1 Troubleshooting
8.2 Anti-interference measures
…8-3
9 PERIPHERAL DEVICES……
9-1
9.1 Connecting diagram of peripheral devices
9.2 Description of options
9-2
C-2
SB60/61 SERIES
GENERAL
1 General
1. I Inspection points upon delivery
Please inspect the following items after unpacking the SB60/SB61
series inverter.
Inspect visually if the product has got any damage during
shipping
Check the nameplate to ensure that the specifications
correspond to those you ordered
Check to see if the accessories shipped together with the
inverter are complete
If you find anything missing, contact our local agents or distributors
pl
ease
2 Type description
SB60
G
0.75
Type
Purpose
Inverter capacity
G: General-purpose SB60: 0.4- 15KW
SB6O(SB61)
P: Pumps fans
SB61:15~400KW
1-1
SB60/61 SERIES
GENERAL
3 Nameplate description
SENLAN INVERTER Made in China
。·●··。。●●ee。
Type: SB60G75
Input: 380V 3-50/60Hz
Output:0-380V3~0.1-400Hz
Rated Current 18A
Rated Capacity 75KW
Serial Number: 1234567
·····················································
CHENGDU HOPE SENLAN INVERTER CO. LTD
1. 4 Product warranty
This product is guaranteed against defects in workmanship for one
year from the purchase date or 18 months from the manufacturing
date indicated on the nameplate. However, for the following failures
or damages, the repair cost should be borne by the customer even
within the warranty period
ailure or damage caused by incorrect operation or by
unauthorized repairs or modifications
Failure or damage due to using the inverter beyond the range
specified on the nameplate
Failure or damage caused by the inverter falling or an accident
during transportation after the purchase
5 Safety precautions
Read the following items before installing, wiring, running and
maintaining the product, and always bear them in your mind
1-2
SB60/61 SERIES
GENERAL
Precautions in this manual fall into two types
Danger
indicates that errors in operation may lead to death
or heavy inJury
Caution
indicates that errors in operation may lead to
medium or light injury to people or damage to
equipmen
(I)Installation
Danger
Install the inverter on a nonflammable object(such as metals).
Otherwise, there may be a risk of fire.
Do not install it in an environment with explosive gas. That may
cause explosion.
Do not install or run the inverter if it is damaged or any
component is missing. Otherwise, accident may occur.
Caution
Install the inverter firmly on an object capable of bearing its
weight. Otherwise, the falling of the inverter may cause injury
or damage
Do not drop any metal materials in the inverter. Otherwise,
accident may occur
1-3
SB60/61 SERIES
GENERAL
(2) Wiring
Danger
Connect a proper circuit-breaker on the input power side of the
inverter. Otherwise, accident may occur, injuring people or
damaging objects
The pe terminal of the inverter must be grounded securely.
Otherwise, electric shock or fire may occur
The wiring must be done by a qualified electrician after the
power is cut off and the high-voltage indicator extinguishes.
Never connect the output terminals(U, v, w) to the input power.
That will destroy the inverter.
Caution
The input power must conform to the specifications on the
nameplate. Otherwise, it may damage the inverter.
1-4
SB60/61 SERIES
GENERAL
3)Operation
D
anger
The power can be switched on only after the wiring is completed
and the cover board is attached otherwise, there may be a risk
of electric shock
Do not touch inverter terminals when electrical power is going to
the inverter even if the motor is stopped. Otherwise, there may
be a risk of electric shock
Do not approach the load if the ' Restart after momentary power
failure' function is selected. The sudden restart of the inverter
may cause electric shock or injury.
Caution
The running inverter can only be stopped by the panel stop key
or external terminals Directly cutting off the main power of the
running inverter is prohibited. That may damage the inverter.
Do not touch the braking resistor when the inverter is running.
Otherwise, there may be a risk of electric shock or burn.
1-5
SB60/61 SERIES
GENERAL
(4)Maintenance
Danger
10 minutes after power-off, use a multimeter measuring the dC
filter capacitor voltage. Only when this voltage is less than 36V.
can the inverter be inspected and repaired. otherwise, there
may be a risk of electric shock or injury
Only professional person can maintain the inverter. otherwise
electric shock or injury may occur.
Do not leave any electricity conductor such as metals etc in the
inverter after repairing it. Otherwise, the inverter may be
damaged
Caution
While charging the inverter that has long not been used it must
be conducted by slowly increasing the input voltage to the rated
value through a voltage regulator. Otherwise, accident may
occur.
(5 Disposal
Caution
When the product is no longer useful, dispose it as an industrial
waste. Otherwise, accident may occur.
1-6
SB60/61 SERIES
INSTALLATION AND WIRING
2 Installation and wiring
2.1 Installation
2. 1. 1 Ambient condition
1040C, with humidity less than 90%. If temperature is over 40C
derate the inverter by 5% for every 1C increase
2.1.2 Installation site
No corrosive, flammable or explosive gases or liquids
No dust, floating fibers or metallic particles
The support is firm and without vibration
■ No direct sunlight
No electromagnetic interference
2.1.3 Installation space and heat dissipation
To ensure good cooling effect, the inverter must be installed
vertically and adequate space maintained around it, as shown below
Air convection
120mm or mor
2-1