文件名称:
日本SMC VK300系列3通电磁阀(直座式底座)/弹性密封说明书(英文版).pdf
开发工具:
文件大小: 321kb
下载次数: 0
上传时间: 2019-10-15
详细说明:日本SMC VK300系列3通电磁阀(直座式底座)/弹性密封说明书(英文版)pdf,日本SMC VK300系列3通电磁阀(直座式底座)/弹性密封说明书(英文版)Series vK300
Manifold Specifications
Specifications
Valve stations
1to20
Dinin method Common SUP, Common EXH
d. Base mounted
vv3K3-s42-0501
Common SUP. Individual EX
Body ported
vv3K320-04
V100
Common SUP/Common EXH
SY
Type 20: Body ported
How to order
Applicable solenoid valve SYJ
(A port top ported)
W3K3-2005}H□
VK332口-口匚口-M5
VK332口-匚口-01
Rc1/8,M5X0.8
Applicable blanking
VK
Valve stations
Thread type
plate assembly
Option
Rc
VK300-42-1A
VZ
Nil
Bracket
2020 stations
With bracket
F
O0NNPT
∨K300-43-1A
VT
(Not mounted
OOT NPTF
P port: Rc
R port: Rc 1/8
VP
Type 40: Base mounted
How to order
Applicable solenoid valve
VG
(a port bottom ported)
VV3K3-40-05}01□
VK334口-口匚口
Applicable blanking
plate assembly
VP
Valve stations
Thread Option
VK300-42-1A
R port: RC 1/8
01 1 station
type
Nil
None
Bracket
S070
Port size
Nil
With bracke
G
A port: RC 1/8
NNPT
(Not mounted)
VQ
NPTF
VKF
Type 42: Base mounted
How to order
Applicable solenoid valve
VK334-匚囗
VQZ
(A port side ported)
V3K34205H01□
Applicable blanking
plate assembly
VZ
VK300-42-1A
Solenoid direction
Thread
Port size
VS
Opposite side
type
of a port
Rc1/8
VEN
A port: Rc 1/8
aPport:Rc 1/8
Same side
C404 cassette
R R port: Rc 1/8
of a port
606 cassette
TNPTF
Valve stations
Tvpe s42
01 1 station
(Solenoids on the same side of A port)
2020 stations
R port: Rc 1/8
Common sUP/Individual eXH
Type 21: Body ported
How to order
Applicable solenoid valve
(A port top ported)
VK332口-口口-M5
VV3K3-2105
VK332凵-L凵凵01
Rc1/8.M5x0.3
Applicable blanking plate
Valve stations↓ Thread
assembly
VK300-42-1A
011station
type
20 20 stations
00F G
OON NPT
R port: RC 1/8
OOT NPTF
LsMC
4-5-3
Series vK300
Combinations of solenoid valve manifold gasket and manifold base
3 port body ported: VK332
3 port base mounted: VK334
X
M3x26
Round head
combination screw
DXT199-23.
wK334口G
WK332-口G01
Manifold gasket
VvK30D-41-2
Applicable base
Applicable base
vv3K3-20
VK300-45-1 Sub-plat
21
VV5K3-20/Manifold base
vV3K3-40
VV5K3-40 >Manifold base
(s)41
(S)42
△ Caution
Mounting Screw
Tightening Torques
Body ported
Base mounted
M3:0.6Nm
Manifold gasket and screw assembly
VK300-41-1A
VK300-41-2A
Note 1) Mounting direction is fixed, do not mount on opposite side
Note 2) Series VK300 can be mounted on manifold base(WV5K 3)of Series VK3o00 For details, refer to Best Pneumatics Vol 3
Combinations of Blanking Plate Assembly and Manifold Base
Blanking plate assembly: VK300-42-1A
M3 x 8
Round head
combination screw
K0-333
Blanking plate
vK300-42-1
Manifold gasket for
blanking plate
△ Caution
vK30041-3
Mounting screw
Applicable base: In common for all types of VV3K3 models
Tightening Torques
M3:0.6Nm
4-5-4
Psvc
3 Port Direct Operated Poppet Solenoid valve
Rubber seal series vk300
Dimensions: Body ported
Grommet: VK332-G-M5
DIN terminal: vk332-0D-M5
688
V100
16
32
2-Q32
SY
(Mounting hole to
(Mounting hole for manifold)
Manual override
SYJ
AlAn I
2-M25×045
「,/ (Mounting screv
(Mounting screw)
pplicable cable o D: 03.5 to 97
VK
对
VZ
12
Bleed hole)
VT
18
62
2-03.5
Bleed hole
VP
23
VG
8
VP
1710
3-M5×08
(P, A, R port)
S070
Refer to grommet type for other dimensions
VQ
VKF
Dimensions: Base mounted
VQZ
Grommet:VK334-□G-01
DIN terminal: VK334-0D-01
VZ
4
VS
(Mountin
VEN
2-043
Manual override
(Mounting
(Non-locking) screw)
Applicable cable O D: 03.5 to 67
Pg7
325
53.1
485
300
628
下
R寸
3-Rc1/8
3S13
13513
P ping porl)
Refer to grommet type for other dimensions
LsMC
4-5-5
Series vK300
Type 20 Manifold Body Ported(Top ported
VV3K3-20- Stations
n1= Number of VK300
Grommet: G
DIN terminal: d
Manual override
(Mounting hole)
Applicable cable O D: 03.5 to o7
785
71
(Lead wire length)
4-Rc1/
4-Rc1/8
2-45
R port
8I/( R port)
hole)
13
4-M3 x 0.5 depth 6
(Bracket mounting screw)
L Dimension
n: Stations
910111213141516171
1920
L1
35547392111130149168187206225244263282301320339358377396
27466584103122141160179198217236255274293312331350369388
1332517089108127146165184203222241260279298317336355374
4-5-6
Psvc
3 Port Direct Operated Poppet Solenoid valve
Rubber seal series
vK300
Type 21 Manifold Body Ported (Top ported)
VV3K3-21-Stations
n1= Number of vK300
Grommet: G
DIN terminal: d
验 Manualoverride
Applicable cable O D: 93.5 to o7
785
V100
300
SY
n1-Rc1/8
(Lead wire length) 2-Rc 1/8
2-Rc18
(P port)
(P port)
SYJ
唐+/ Mounting hole)
惶的
VK
P=1935
55
VZ
VT
VP
VG
VP
n-Rc 1/8
1919
(R port)
S070
VQ
L Dimension
n: Stations
2
VKF
3
6
10111213141516
181920
L1
38577695114133152171190209228247266285304323342361380399
27466584103122|1411601791921729625274293312318503699VQZ
VZ
VS
VEN
LsMC
4-5-7
Series vK300
Type 40 Manifold Base Mounted(Bottom ported)
VV3K3-40-Stations -01
Grommet: G
DIN terminal: d
G
o Applicable cable O D: 03.5 to o7
835
Manual override
5
(Non-locking)
(Lead wire lengt
(P, R port)
2-04.5
818
(Pitch)
1.5
P=19135
105
105
49.5
8
4M3×0.5 depth6
(Bracket mounting screw)
P=1916
(A port
P
L Dimension
n: Stations
6
1213141516
181920
L13756759411313215117018920822724626528430332234136037398
27466584103122141160179198217236255274293312331350369388
13325170891081271461651842032224125027929831733355374
4-5-8
Psvc
3 Port Direct Operated Poppet Solenoid valve
Rubber seal series vk300
Type 42 Manifold Base Mounted (Side ported)
VV3K3-42-Stations -01
Grommet: G
DIN terminal: D
Applicable cable O D: 03.5 to e7
83.5
Manual override
300
V100
ead wire lengt
115
SY
a
SYJ
Pitch
8
VK
2-04.5
P=1914
8.5
Mounting hole
4-Rc1/8
4-Rc1/8
(P, R port
VZ
(P, R port)
VT
VP
A
A&
VG
n-Rc 1/8
P=1914.5
VP
(A port)
S070
Built-in One-touch fitting VV3K3-42-Stations -C4, C6
Solenoid at a port side:
VQ
VV3K3-S42-Stations
VKF
VQZ
1914L5
24.5
VZ
Manual override
(Non-locking)
VS
(Lead wire length)
P R
wA〓
VEN
2-04.5
(Pitch)
5
(Mounting hole
P=194
Manual override
(Non-locking
3并西
A
图
n-One-touch fitting
n-Rc 1/8
P=1920
C4: Applicable tubing 10425
C8: Appllo
llicable tubing to604
19145
Refer to the above drawing for DIN terminal dimensions
Refer to the above drawing for other
dimensions
1234567891011121314151617
38577695114133152171190209228247266285304323342
380399
28476685104123142161180199218237256275294313332
370389
LsMC
4-5-9
Series vK300
A Precautions
I Be sure to read before handling. For Safety Instructions and solenoid valve Precautions, refer to page 4-18-2. F
How to wire din Terminal
Light/Surge Voltage Suppressor
Valve Mounting Direction
△ Caution
A Caution
A Warning
● Connecti
Rated Grommet(G) DIN terminal(D) ag When mounting a valve on the manifold
1. Loosen the set screw and pu
connector from the terminal block of the
voltageVW
duly iype(
ty type(E
E5 base or sub-plate, etc, the mounting
solenoid
orientation is already decided. If mounted
2. Remove screw and insert screwdriver into
;5
in a wrong direction, the equipment to be
the slit area near the bottom of terminal
connected may result in malfunction
block to separate block and housing
Refer to pages 4-5-4 to 4-5.9 for external
3. Loosen the terminal screws(slotted
dimensions in mounting
screws)on the terminal block, insert the
core of the lead wire into the terminal
Nne[掉z
Vacuum Spec Type: VK330V
and attach securely with the terminal
In contrast to the standard product, this
scre
vacuum specification valve has less air
4. Tighten the ground nut to secure the wire
MC:1+)
leakage at low pressures, a feature that
A Caution
should be taken into consideration when
Use caution in wiring because it will not
using this valve for vacuum applications
meet the IP65(enclosure) standard if you
24V1+
A Caution
use the other cord than prescribed heavy
duty cord of size(03.5 to o7.5)
∠8V
Since this valve has slight air leakage
Tighten the ground nut and set screw within
Z
it can not be used for holding vacuum
the specified range of torque
(including positive pressure holding) in
O Change of electrical entry (orientation)
№?(-
the pressure container
After separating terminal block and
housing, the cord entry direction can be
Continuous Duty Type: VK33DE
changed by attaching the housing in the
目中平
Exclusive use of Vt317E is recom
desired direction (4 directions in 90
mended for continuous duty with long
increments
6V
time loading.
sIn the case of w/ indicator light, avoid
12V
damaging the light with lead wire
A Caution
● Precautions
None
1. This model is for continuous duty, not
Plug a connector in or out vertically, never
for high cycle rates. But even in low
at an angle
cycle rates, if energizing the valve more
● Applicable cable
O.D. 03.5 t0 07
Precautions on connection of 24V or more dc
than once a day, please consult with
(Reference
Grommet type should be connected as following
SMC
0.5 mm2 2 core and 3 core wires
Red lead wire for (+)side, Black lead wire for ( 2. Energizing solenoid should be done at
equivalent to JIS C 3306
least once in 30 days
With the DIN terminal, connect the positive(+) side
Ground nut
folding screw
to the connector's no. 1 terminal, and the negative
How to calculate the flow rate
Tightening torque
1.65to2.5Nm
( side to the no. 2 terminal. [Refer to the marks
0.3to04N
Washer
on the terminal board
For obtaining the flow rate, refer to page
Grommet
For 12 VDC or below, there is no positive(+)or 4-1-6
Rubber)
gative (-)d
(Voltage symbol)c
Position for
● Grommet type
Refer to the
Re(+)
table below
Terminal block
Terminal scren (3 positions)
Slot area
Black (-
Tight
to 0.25 N
O Connector part no. VK300-82-1
suppress
O Part no. of connector with indicator light
Rated voltage Voltage symbol
100 VAC
100V
VK300-822-01
110 VAC
110V
VK300-822-03
200 VAC
200V
VK300-822-02
220 VAC
220V
VK300-822-04
●D| N terminal type
240 VAC
240V
VK300-82207
6 VDC
VK300-82-4-51
12 VDC
12V
VK300-824-06
24 VDC
24VD
VK300-823-05
Indicator light
Built-in connector)
48 VDC
48VD
VK300-823-53
O Circuit with indicator light
12 VDC or le
24VDC or
Surge voltage
circuit diagra
circuit diagram
suppress
(Built-in terminal
求 Marking
AC. 12 VDC or
For 24V or more
less for dc
NL: Neon bulb LED: Light emitting D: P
×于
d: Resister
R: Resister
LED: Light emitting
ode
Resister
4-5-10
Psvc
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.