您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 丹佛斯 变频器Modibus Plus现场总线选件卡手册.pdf
  所属分类: 其它
  开发工具:
  文件大小: 742kb
  下载次数: 0
  上传时间: 2019-10-15
  提 供 者: weixin_********
 详细说明:丹佛斯 变频器Modibus Plus现场总线选件卡手册pdf,The documentation in this manual is intended to provide you with comprehensive information on how to set up your Modbus Plus Option Card for communication over a Modbus Plus communication link.VLT 5000 Series Modbus Plus Option Card Product overview Introduction The documentation in this manual is intended to provide you with comprehensive intormation on how to set up your Modbus Plus Option card for communication over a Modbus plus communication link About this This manual is intended to be used both as communication system. The list of contents is manua an instructional and a reference manual. It also a decision route that will guide you only brietly touches on the basics of the through the decisions you have to make Modbus Plus protocol whenever it is before you set up your system necessary for gaining an understanding of the Modbus plus option Card for the danfoss Even if you are an experienced Modbus Plus VLT 5000 Series programmer, we suggest that you read this manual in its entirety before you start This manual is also intended to serve as a programming, since important information guideline when you specify and optimize your can be found in all sections Assumptions This manual assumes that you are using a application. Also all requirements stipulated in Modbus Plus option Card in conjunction with the Modbus Plus standard as well as well as a danfoss vlt 5000 Series Drive. It is alsc those pertaining to the VLt Variable Speed assuming that you as a master, are using a Drive, are strictly observed as well as all PLC or Pc that is equipped with a serial mutations therein fully respected communication card supporting all the Modbus plus communication services required by your What you should The Danfoss Modbus Plus Option Card is therefore assumed that you have ful already know designed to communicate with any master knowledge of the PC or PLC you intend to abiding by the Modbus Plus standard. It is use as a master in your system VLT 5000 Series Modbus Plus option Card Agency Approval The Modbus Plus Option Card is UL listed and cUL approved The Modbus Plus Option card is Ce pending consult factory Danfoss is a modconnect partner Modbus plus Style Enclosure VLT 5000 Modbus Order No. Modbus Order No Part numbers Description with memory card ithout memory card Bookstyle 5001-5006,200-240V176F1550 176F1558 5001-5011,380-500V Compact Chassis5001-5027,200-240∨176F1551 176F1559 5001-5052,380-500V Compact NEMA1250015027,200-240176F1550 176F1558 5001-5052,380-500V Compact Chassis5032-5052,200-240V176F1551 176F1559 5060-5250,380-500 Compact NEMA125032-5052,200-240176F1551 176F1559 5060-5250,380-500V Additional 175R5285-Option Card Installation GM-MBL-001 RevD- MODICoN Modbus Reference Instructions Plus Network Planning and Installation guide Literature 175R5271-VLT 5000 Series Adjustable Frequency Drive Instruction Appropriate Modicon Programmable Manual Controller Systems"manual for your equipment. Contact Danfoss for these manuals. (Contact MODICON for these manuals. 4 a VLT 5000 Series Modbus Plus Option Card Installlation The following installation section is specitic to the Modbus Plus option card. For more specific intormation on installation and operation of the VLt 5000 refer to the VLT 5000 Series Adjustable Frequency Drive Instruction Manual 175R5271 WARNING: The VLT Adjustable Frequency Drive contains dangerous voltages when connected to line voltage. After disconnecting from the line wait at least 15 minutes before touching any electrical components. Only a competent electrician should carry out the electrical installation. Improper installation of the motor or the vLT may cause equipment failure, serious injury or death follow this manual and national electrical codes and local safety codes WARNING Electrostatic Precaution; Electrostatic discharge(ESD). Many electronic components are sensitive to static electricity. Voltages so low that they cannot be felt, seen or heard, can reduce the life, affect performance, or completely destroy sensitive electronic components. When performing service, proper ESD equipment should be used to prevent possible damage from occurring CAUTION It is the responsibility of the user or the person installing the VLT to provide proper grounding, as well as motor overload and branch circuit protection according to the National Electrical Code and local codes VLT 5000 Series Modbus Plus option Card Installation for Bookstyle Units 1. Access to Control To remove the Local Control Panel (LCP) A Card cassette pull at the top of display(a) To remove the protective cover gently pry at the notch(B 2. Removing Remove any control wiring by unplugging Cassette the terminals and removing the ground Unscrew the two captive screws (A) securing the cassette to the Chassis Lift at the bottom of the cassette( B) and unhinge at the top (A) ①-K)② (B) a VLT 5000 Series Modbus Plus Option Card 3. Removing Ribbon Unplug the two ribbon cables(A) and(B Cables from the control NOTE: The ribbon cables will need to be replaced on the same connections from which they were removed (A) 4. Removing LCP Carefully push in at the right side corners of we Press cradle the LCP cradle to release clips, and gently pull out to release clips at left side Lift Press (A) 5. Ribbon cable Be sure that the exposed wire portion of the Installation on ribbon cable(A) is facing the front of the Option Cards socket (B) Pull up the collar(C)of the ribbon cable socket, insert the cable and push the collar (c) closed Repeat for all ribbon cables. TTmInTnmm 山 Memory card K( Control car VLT 5000 Series Modbus Plus option Card 6. Modbus plus NOTE: Address switch settings need to be Address Switch made prior to option card installation Reter to Understanding Module Address Switches section in this manual Address Switches 7. Ribbon cable Carefully route cables through the opening Routeing in the back of cassette(A) (A) 8. Securing Option Slide the edge of the option card into the Card slot in the side of the cassette ( A Secure the other edge of the option card with the self-tapping screws provided (B torque the screws to7.1 LB. IN a VLT 5000 Series Modbus Plus Option Card 9. Ribbon cable Be sure not to twist cables installation on Insert cables in corresponding sockets Control card 上口 ■■■■■■■■■■■ 10. Ribbon cable Be sure that the exposed wire portion o (A) installation on the ribbon cable (A)is facing the front of the Control card socket(B Pull up the collar(C)of the ribbon cable l山 socket, insert the cable and push the collar Repeat for all ribbon cable B 11. Replace the LCP Insert the right side clips first Cradle Push down on the right side to snap into place. VLT 5000 Series Modbus Plus option Card 12. Replacing the Re-connect the ribbon cables a and B Cassette NOTE: The ribbon cables will need to be on the same which they were removed B (A) 13. Replacing the Hinge the control card cassette at the top of the drive(a)ar hten the two s (B)to7.9LB·N Replace the LCP, control signal wiring protective cover. 恐 14. Network Network connector installs through the top Connector of the control card cassette Remove connector access knock-out(A)in top cover of drive 15. Wiring Bracket ing bracket b)to the top of the (B) drive and torque screws to 10.6 LB NOTE: Cable clamps are to be placed over the wire insulation for strain relief only. DO NoT ground the cable shield
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: