详细说明:Fuji POD UG series(Reference)(3)pdf,Fuji POD UG series(Reference)(3)Contents
System Setting
国 PLC models…:1
Printing Bit Samples in Displayed Format………3
Converting DIO Input Memory Bits
About sampling mode
■ Alarm Display UG口20only)
About Macros(Applicable to UGa20 only).
446
Adding Macro Commands
Transfer
Adding communication port
File management m.
Comparing
Fil
8
Using Satohs MR400 Series Barcode Printer
(Applicable to UG20 Only).
Connecting Cables
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
9
Using Memory Card.………………………9
Setting in UGoOS-CW
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
10
Format ta|e……an
11
Macros added for mr400 Series……15
Bar code type CODE39.……………………………16
Ladder Transfer Function(Applicable to UG20 Only19
Overview.sm 19
Applicable PLC.…………………………………20
Applicable Models……………………20
Applicable Versions and Local Main Screen aaaeaaaaaaeaaaaamaeaaaa. 20
Connection
Setting Procedure and Communications……22
Precautions for Using Ladder transfer Function mamma 24
About ladder transfer Function errors
n24
Transferring Screen Data Using Modem
(Applicable to UG20 Only. aBBIRRRRAAARRBRIRIRRIIETRRRIaaan 25
国 Preparation and setup Procedure…25
Setting AT commands ane..26
Setting POD Main Unit……………28
Connection
Transmitting screen Data .seseseesemasasmnsessasnan n 31
Transfer Errors Displayed on UG00s-CW.……32
Error Display,,……,…,33
UG00S-CW Additional spec ific a tions
System Setting
Plc models
The following models marked tr(5 models) have been added in order to adapt to PlCs
from 3 1 makers
The models marked *k cannot be set by the UG400/210
Model
Calendar
FUJI MICRE×F(T-ink)
depends on the model
FUJI MICREX-SX (T-link)
provided
FUJI MICREX-SX ( JPCN1
not provided
FUJI FLEX-PC (JPCN1
not provided
FUJM| CREX-SⅩ( SX bus
provided
FUJI MICREX-F Series
depends on the model
FUJI MICREX-SX Series
rovided
FUJI MICREX-SX CPU
provided
FUJI FLEX-PC Series
depends on the model
FUJI FLEX-PC CPU
depends on the model
FUJI FLEX-PC COM
provided
FUJI FLEX-PC ( T
depends on the model
FUJI FLEX-PC CPU(T
depends on the model
MITSUBISHI AnA/N Series
provided
MITSUBISHI QnA Series
provided
*k MITSUBISHI Qnh(Q) Series
provided
MITSUBISHI A CPU port
provided
MITSUBISHI FX Series
depends on the model
冰M|TSUB|SH|Net10
provided
MITSUBISHI QnA CPU port
provided
*k MITSUBISHI QnH CPU port(A
provided
*k MITSUBISHI QnH CPU port(Q)
provided
*K MITSUBISHI FX Series(A protocol)
provided
k MITSUBISHI AnA/N/U (JPCN1)
provided
k MITSUBISHI FX2N Series
provided
k MITSUBISHI EX1S Series
provided
k MITSUBISHIA Series CC-Link
provided
k MITSUBISHI QnA CC-Link
provided
*k MITSUBISHI QnH(Q)Series CC-Link provided
k MITSUBISH QnA Series(Ethernet)
provided
k MITSUBISH QnH(Q)Ethernet
provided
OMRON SYSMAC C
depends on the model
*k OMRON SYSMAC C (JPCN1)
depends on the model
OMRON SYSMAC CV
provided
米 OMRON SYSMAC CS1
provided
k OMRON SYSMAC CS1 DNA
provided
SHARP JW Series
provided
SHARP JW100/70H COM port
provided
SHARP JW20 COM port
provided
冰 SHARP JW(FLNe
provided
HITACHI HIDIC-H
provided
HITACHI HIDIC-S10/2a
not provided
HITACHI HIDIC-S1O/ABS
not provided
冰 HITACHI HIDIC-S10(PCN1
not provided
MATSUSHITA MEWNET
depends on the model
YOKOGAWA FA500
provided
YOKOGAWA FA-M3
provided
k YOKOGAWA FA-M3/FA-M3R(Ethernet) provided
UG OOS-CW Additional spec ific a tions
米 YOKOGAWA FA-M3R
provided
k YOKOGAWA FA-M3R(FL-Net
provided
YASUKAWA Memo-bus
depends on the model
k YASUKAWA CP9200SH/MP900
not provided
TOYOPUC
provided
KOYO SU/SG
provided
KOYO SR-T
provided
冰 KOYO SR-T( K protocol)
not provided
*k KOYO SR-T( K-Sequence)
provided
A B PLC-5
not provided
A B SLC500
provided
A b Micro Logix 1000
not provided
☆米 A B Control Logiⅸx
not provided
GE Fanuc 90 series
not provided
GE Fanuc 90 Series(SNP-X)
not provided
TOSHIBA T Series
provided
k TOSHIBA MACHINE TC200
provided
冰S| EMENS S5
not provided
冰S| EMENS S7
not provided
k SIEMENS S7 PROFIBUS-DP
not provided
SIEMENS S5 UG400 compatible
not provided
SIEMENS TI500 /505
provided
SIEMENS TI500/505(UG400 compatible) provided
SIEMENS S7-200 PPI
provided
米 SIEMENS S5 PG port
not provided
*k SIEMENS S7-300MPI (HMI ADP)
not provided
*k SIEMENS S7-300MPI(PC ADP)
not provided
SHINKO SELMART
provide
SAMSUMG SPC Series
not provided
米 SAMSUMG N-P|us
provided
冰 SAMSUMG SECNET
depends on the model
KEYENCE KZ Series
not provided
KEYENCE KZ-A500 CPU port
provided
米 KEYENCE KV Series
not provided
k KeYEnCE KZ24/300 Series cPu
not provided
k KEYENCE KV10/24 Series CPU
not provided
☆米 KEYENCE KV7000 Series CPU
provided
LG MASTER-K10/60/200
not provided
LG MASTER-K500/1000
not provided
米 LG LGMKX00S
not provided
水 LG MASTER-KXXXS CENT
not provided
米 LG GLOFA CENT
not provided
FANUC Power mate
not provided
FATEK AUTOMATION FACON FB Series provided
IZUMI IDEC MICRO3
provided
米 modiCon Modbus rtu
depends on the model
米 YAMATAKE MX Series
provided
k TAIAN Electric Co. Ltd. tP02
provided
米SA|APCD
provided
冰 MOELLER PS4
not provided
a* Telemecanique TSX Micro
not provided
k Automationdirect direct loGic
provide
** Automationdirect Direct LOGIC (K-Sequence)provided
☆来 VIGOR M Series
depends on the model
☆冰 DELTA DVP Series
not provided
k General-purpose FL-Net
not provided
General-purpose serial
UG00S-CW Additional spec ific a tions
Printing Bit Sa mples in Displayed Fomat
Printing bit sampling data causes all data stored in the buffer including On/OFF
conditions to be printed. From the next version, selecting [Print out the data of bit
This does not apply sampling with the display type] allows printing only the data of the current display
to the g400/ 210
format
O Setup procedure
1 Update the main program
2 Select [System Setting], [Others.], [Others/P3], and then [ pRint out the data
of bit sampling with the display type
Converting DIo Input Memory Bits
For PlC with special bit assignments(see the description below ) bit conversion should
This does not apply
to the ug400/ 210
be carried out inside the Pod. currently bit conversion is not carried out for the dio
input memory and done for the dio output memory, therefore, the bit assignment
image is different between input and output
From the next version, selecting [Convert DIO Input Memory to bit memory] causes bit
Set [Dlo input
conversion to be carried out also for the dio input memory
Mem] and [DlO
output Mem] by
selecting [Others,
P2] from [System
Setting]
w Currently supported PLC models that require bit conversion
Fuji micreX-F(other than T-LiNK 1O memory)
Bit weight inverted
Hitachi HIDIC-s10 a(other than JPCN-l 1/O memory ) Bit weight inverted
SIEMENS S5 Series(only device memory at byte address ): Byte weight inverted
SIEMENS S7 Series(only device memory at byte address): Byte weight inverted
O Setup procedure
Select [System Setting], [Others.], [Others/P3], and then [u Convert DIO Input
Memory to bit memory
UG OOS-CW Additional spec ific a tions
About Sampling mode
Alarm Display(UG20 only)
o Two functions have been added to alarm display:
This does not apply
o Selecting whether or not to store message for each bit
to the ug400/210
This function enables to select whether or not to store the alarm message
depending on its severity
Example
Line 1 Stop bit
OFF
Line 1 Service bit
When Line 1 Stop and Line 1 Service bits are set to
When [Memorize] is not selected for the Line 1 service b
Line1 S
15:42:2015:43:50
15: 43: 59 15: 44: 10: the history of the Line1 Service bit is not saved. In this case,
Line 1 Service
15:46:0015:46:20
the following display will not appear
Line1 Stop
15:46:3015:47:20
Occurrence time Reset time
Line 1 Sto
15:42:2015:43:50
Line 1 sto
15:44:2015:45:50
Line 1 sto
15:46:3015:47:20
◆ Setup procedure
From the [Message Edit] window, select [Display] and click [Display
Change. to change the display
囗回回曰團倒團國园回回■-。
国画■山國圓
000 M000000 a Lineal Ston
Line2 Ston
[600
[007 M000007 M Linc8 Stop
By selecting [No. [ Relay No ] and [memorize] from
Display], whether or not to display the line numbers, relay v status bar
numbers, and stored messages can be set
UG00S-CW Additional spec ific a tions
o Acquiring alarm memory information
The number of the message used for alarm display with [memorize] set
OFF can be read with macro command SYS (GET BUF)
°[SYS( GET BUF)F1
Reads the alarm memory information
Available devices
Internal memory memory Constant/Mem
PLC
ndirect
card specification
W-word
Fo Command name
F1
GET_BUF: Alarm mask information read SYS(GET BUF)F
F1+0 Message group No.
F1+1 Alarm mask information(related to each message line)(+UG)
?F1+1 Bit 0: O'th line of message
F1+16
Bit 1: First line of message
Bit 2: Second line of message
F1+16 Bit 15: 255th line of message
Setting a message group No. in memory F1+0 causes to store the message
No. masked to F1+1 through F1+16
2 Displaying alarm occurrence time
Displaying alarm occurrence time as the time information attached to the error
message.
Alarm occurrence time
Alarm occurrence time
Alarm occurrence time
Line 1 Stop bit
Line 1 Service bit
OFF
Alarm occurrence time
Alarm occurrence time
Alarm occurrence time
Line1 Stop
0:1:30
Line 1 Service
0:0:11
Line 1 Sto
Line 1 Service
0:0:20
Line 1 Stop
0:0:50
◆ Setup procedure
From the [Alarm Display] dialog, select [Display Mode] and then [Occurrence
Time Display
UG OOS-CW Additional spec ific a tions
About Macros (Applicable to UGo20 Only)
Adding Macro Commands
o Bar code printer MR400 Series(See page 9.)
Command name
Description
MR REG
EXecutes MR400 format table registration set number
MR REG FO
MR OUT
Executes mR400 format table call set number
MR OUT FO
O SYS command
Command name
Description
GET BUF
Alarm funct
SYS(GET BUF)F1 (See page 4.)
UG00S-CW Additional spec ific a tions
Transfer
Adding communication port
To enable transfer to/from the editor (UsooS-CW)side, set the communication ports on
the personal computer(PC). Available communication ports were COMl to COM4, but
CoMI to coma are now available
fans
Transfer Device
Transfer Data
C I/F DI
C Memory
Program
Use Simulator
C Font Data
n Read comments in data transfer
C Temp. Control
厂 All data tan
V Read variables in data transfer
Baud Rate
Transfer through Ethernet
C COM1
C9600bp8
C 19200bp
C COM3
C38400bs
Transfer
CCOM4
c 57600bps
C115200bps
PC<
C COM6
C COM7
OK
C COMa
Cancel
Cancel
Detail Setting
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.