您好,欢迎光临本网站![请登录][注册会员]  
文件名称: Fuji MICREX-SX SPH General Purpose Communication Pacaage for Factory Automation Machine.pdf
  所属分类: 其它
  开发工具:
  文件大小: 812kb
  下载次数: 0
  上传时间: 2019-10-15
  提 供 者: weixin_********
 详细说明:Fuji MICREX-SX SPH General Purpose Communication Pacaage for Factory Automation Machinepdf,Fuji MICREX-SX SPH General Purpose Communication Pacaage for Factory Automation MachineSafety Precautions Before mounting, wiring, operation, maintenance and inspection of the device, be sure to read the operating instructions carefully to ensure proper operation The operation instructions should be furnished to the maintenance supervisions of final users Warning: Incorrect handling of the device may result in death or serious injury △ Caution: Incorrect handling of the device may result in minor injury or physical damage Even some items indicated by "Caution"may also result in a serious accident Both satety instruction categories provide important information. Be sure to strictly observe these instructions △ Caution Do not bring the magnetic object close to the floppy disk, otherwise, failure might be caused Insert the memory cassette, floppy disk and engage the loader connector in a correct orientation, otherwise, failure or erratic operation might be caused Sufficiently make sure of safety before program change, forced output, starting, stopping or anything else during a run The wrong operation might break or cause machine problems Do not turn off the loader during a run(accessing to the hard disk or the floppy disk, communicating to the PLC) otherwise, missing of data, failure or erratic operation of products, damage or trouble of machines might be caused Use this package in the operating environment of software described in the user's manual, otherwise, failure or erratic operation might be caused Perform the version-up operation by the explanation of the user's manual, otherwise, failure or erratic operation might be caused Engage the communication cable connector firmly and lock it, otherwise, erratic operation be might caused Do not touch the disk's surface of the floppy disk, otherwise, failure or erratic operation might be caused Perform the periodic inspection for the floppy disk drive and the hard disk drive. If the data are made by the fault disk failure or erratic operation of the system might be caused When disengaging the communication cable or the power cable, do not pull the cord, otherwise, failure, erratic operation or damage might be caused Precautions for using the General Purpose Communication Package of Factory Automation Machine To use the expansion FB included in the General Purpose Communication Package of Factory Automation Machine, it is necessary to register "_c_com pwt "in the common library. c_compwt is included in the standard expansion FB that is supplied with D300win. When you use the expansion FB for 1.0.0.1 or newer version of General Purpose Communication Package of Factory Automation Machine, be sure to use the"_c_com" that is included in 1.1.1.0 or newer version of standard expansion FB package(supplied with 1.2.0.0 or newer version of D300win system). Revision Manual no, is shown on the cover Printed on *Manual no Revision contents Jan.2001 FEH240 First edition Contents Preface Safety Precautions Precautions for using the General Purpose Communication Package of Factory Automation Machine Revision Contents ge Section 1 General 1-1 System Configuration 1-2 FBs in the General Purpose Communication Package for Factory Automation Machine…… ■■■■面面国面西面■D■着面面重重■■■■面噩■■I 1-3 General Usage of this Package. Section 2 Installation ■■■■■■■■■■■■■■■■■m■■■■■■■■■■■■■口■■■■■■■■■■■m■mmm■■■口■量■■■■m■量■■■■mmmm 2-1Installation procedure n2-1 2-2 Registrtion/ Deletion in Library…… 日 2-3 221 Registrtion in library…… 2-3 2-2-2 Deletion from library 2-3 Uninstallation Procedure …2-5 2-4 Supplementary Explanation for Installation 重■■■■■口■■■■■■■■ 2-6 2-4-1 About the file in the package 2-6 2-4-2 Common library Section3 Temperature Controller FB…………,…,…,…,……,…3-1 3-1 RIKA KOGYou CrkREX ……3-1 3-1-1 General 3-1 3-1-2 Specifications for CrkREX 3-2 3-1-3 Initialization 3-1-4 Selecting 3-6 3-1-5 Polling .. 3-8 3-1-6 RAS information 3-10 3-2 OMRoN ComAX,…3-11 3-2-1 General 3-2-2 Specification for comAX 3-12 3-2-3 Initialization 3-14 3-2-4 Data sending/receiving 3-16 3-2-5 RAS information 33 oMRon Cock....…...….…...….………3-19 3-3-1 General 3-19 3-3-2 Specifications for ComCK E· 3-20 3-3-3 Initialization 3-22 3-3-4 Data sending/receIving 3-24 3-3-5 RAS information .326 Contents 3-4 Yamatake CymSDC..…..…..,..,,.…………,.,,………,…,,………3-27 3-4-1 General 3-27 3-4-2 Specifications for CymSDC 3-4-3 Initialization ∴3-30 34-4 Data sending/receiving…… “411 3-32 3-4-5 RAS information 3-34 Section 4 ID System FB 4-1 oMron Come 4-1 4-1-1G 4-1-2 Specifications for ComV6 4-1-3 Initialization 4-1-4 Data sending/receiving 4-6 4-1-5 RAS information… 4-8 4-2 SHARP CshDS∴ 4-9 4-2-1 General 4 4-2-2 Specifications for CshDS 4-10 4-2-3 Initialization 4-12 4-2-4 Data sending 4-14 4-2-5 Data receiving 4-16 4-2-6 RAS information 4-18 4-3 Yamatake CymWAM.…… 4-19 4-3-1 General 4-3-2 Specifications for CymWAM…… 4-20 4-3-3 Initialization 4-22 43-4 Data sending/receiving…………………… 4-24 4-3-5 RAS information…… 4-26 4-4 IZUMI CizFP ■■■■ 4-27 4-4-1 General 4-27 4-4-2 Specifications for CizFP 4-28 4-4-3 Initialization 4-30 4-4-4 Data sending/receiving 4-4-5 RAS information 4-34 Section 5 Bar Code reader FB 5-1 5-1 THoKen CtkTCD 5-1-1 General 5-1 5-1-2 Specifications for CtkTCD 5-1-3 Initialization 5-1-4 Data sending 5-1-5 Data receiving… 5-7 5-1-6 RAS information 5-2 NIPPON ELECTRIC INDUSTRY CndBcc mmmmmmmmmm 5-9 5-2-1 General 5-2-2 Specifications for CndBCC 5-2-3 Initialization 5-12 5-2-4 Data sending .5-14 5-2-5 Data receivin 5-16 5-2-6 RAS information 5-17 Contents 5-3 KEYENCE Cky BL…,……,…,………,…,…,…,…,…,,…,………………5-18 5-3-1 General 5-3-2 Specifications for_ Cky BL 5-19 5-3-3 Initialization 5-21 5-3-4 Data sending… 5-24 5-3-5 Data receiving .5-26 5-3-6 RAS information 5-27 5-4 IZUMI DATA LOGIC CizDS 5-28 5-4-1 General 面面面 5-28 5-4-2 Specifications for CizDS 5-4-3 Initialization 5-31 5-4-4 Data sendin 5-33 5-4-5 Data receiving… 5-34 5-4-6 RAS information 5-35 Section6 SECS FB∴ 6 6-1c§EC56-1 6-1-1 General 6-1-2 Specifications for C_ SECS ∴62 6-1-3 Initialization 6-4 6-1-4 Data sending 6-6 6-1-5 Data receiving… 6-8 6-1-6 RAS information 6-9 Section 7 FANUC DNC2 FB 7-1 7-1 FANUC CDNC2 n…7-1 7-1-1 General 7-1 7-1-2 Specifications for CDNC2 7-2 7-1-3 Initialization 7-4 7-1-4 Data sending… 7-1-5 RAS information 7-8 Section 8 Serial Printer Controller fb 日aBaa益 000000n0000dD日Q 8-1 Print………… 8-1 8-1-1 General 8-1 8-1-2 Specifications for print 8-2 8-1-3 Initialization 8-3 8-1-4 Data sending… 8-5 8-1-5 RAS information ∴8-6 Section 1 General Page 1-1 System Configuration ■■■■圈■■■■D■ 1-2 FBs in the General Purpose Communication Package for Factory Automation Machine…… 1-2 1-3 General Usage of this Package. Section 1 General 1-1 System Configuration General purpose communication package for Factory Automation machine NP4N-COMF is a collection package of the temperature controllers or the bar code readers, etc. SX bus CPU module o50 Communication RS-232C on Rs-485 External device loade There are two connecting methods to connect a general purpose communication module with the external device As connecting method depends on each FB, refer to the operating instructions of the external device for details 1: 1 Connection using RS-232C General purpose RS-232C External device module 1: N Connection using RS-485 General purpose Rs-485 communication nodule External device External device
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: