文件名称:
美国泰科 Biffi F02 系列电动执行器英文样本.pdf
开发工具:
文件大小: 876kb
下载次数: 0
上传时间: 2019-10-14
详细说明:美国泰科 Biffi F02 系列电动执行器英文样本pdf,美国泰科 Biffi F02 系列电动执行器选型参数介绍BIFFI F02 Electric Actuator
Models F063 to F2KO
New Standards for the Small Electric Quarter-turn Market
Control Panel offers easy
Separate terminal block for
setting of all functions from
safe and easy field wiring
one location
terminations
All metal, self-locking, epi-cyclical
internal gearing ensures a smooth
and reliable operation
Copyright 2007 Tyco Flow Control. All rights reserved
BIFMC-0472
BIFFI F02 Electric Actuator
Models F063 to F2KO
Option Modules
OM1- Servoamp and
OM3- Local Interface
OM10- FouNDATION M fieldbus
Retransmission Module(available Integral pushbutton panel with
(available with integral Bluetooth
with integral bluetooth Non-
Local/ Remote Selector, Open/Close
Non-intrusive Configuration)
intrusive Configuration
pushbuttons and 2 LED's(Red/Green)
Ff interface module
Analog Position INPUT of 4 to 20 mA or
for local indication
0 to 10 VDC (selectable)
oM11- DeviceNetTM Module
oM4- Non-intrusive
available with integral bluetooth
Analog position oUTPut of 4 to 20 mA
Configuration Tool
Non-intrusive Configuration)
or o to 10 VDC(selectable)
A module with bluetooth wireless
DeviceNettm interface module
Monitor Relay Alarm contact to indicate
technology allows non-intrusive
oss of power, torque alarm, over
configuration of on-off actuators
temperature of motor or electronics and
oss of analog signal
OM13-Three-wire interface
Notes
control module
Motor Running output contact
1. AS-interface is a registered trademark of
Converts unit to three-wire configuration
AS-International
Four additional SPST Output Contacts
where power and directional control are
2. The Bluetooth word mark and logos are
set independently at one of 10 points
the same
owned by the Bluctooth SIG, Inc and ar
use of such marks by tyco Flow Control is
along the stroke
under license
BUS Communication- Network
Contacts are configurable(make or
3. Foundation " M fieldbus is a registered
Interface
trademark of the fieldbus Foundation
break)
Optional network interface modules to
4. PROFIBUSe is a registered trademark of
PROFIBUS International
Non-intrusive Configuration of
allow communication with BUS systems
These modules are plug and play.
5. Device Nettm is a registered trademark of
Servoamp/Retransmission
ODVA
Optional -OM1 module may be
OM8-AS-interface Module
specified with integral, non-intrusive,
configuration using Bluetooth wireless
(available with integral Bluetooth
Non- intrusive Configuration)
technology protocol
ASi 2.1/2.2 module
OM2-Battery Backup Module
oM9- PROFIBUSO DPVO and
Provides power so that the remote
contacts will update whenever the main
DPV1(available with integral
Bluetooth Non-intrusive
power supply to the actuator is lost
Configuration
PROFIBUSO DPVO cyclic
communication and acyclic
communication as per ProFiBUs
DPV1 extension
Fieldbus
F
oundation
Devicenet-
NTERFACE
PROCESS FIELD BUS
Bluetooth
Copyright 2007 Tyco Flow Control. All rights reserved
B|FMC-0472
BIFFI F02 Electric Actuator
Models F063 to F2KO
Non-Intrusive Operations
Non-intrusive wireless control is now
always available, in your hands and in
available to the small quarter-turn
your office With a smart user-friendly
electric market Using Biffi developed
graphic inte
l the actuator
software for pc and pda you can now
information, set-up, configuration data
communicate with the fo2 using
diagnostic messages and data logger
Bluetooth wireless protocols. With the
info are available for analysis and
new software. control of the fo2 is
reconfiguration from your PDA or PC
PDA Manager
The Pda Manager will transform your
F02 is available with bluetooth non-
PDA Manager uses Windows Mobile
common pda or dedicated industrial
intrusive communication for both on -off
2003 for Pocket PC(or later)Operating
PDa into a strong tool for the complete
and modulating operation Using
System, and requires bluetooth 1.1
control, set-up and diagnostics of the
Bluetooth communication, it is possible compliant (or later)
F02 actuators installed in your plant. A
to communicate with the actuator within
All the data exchanged with the actuator
user-friendly graphic interface
a distance of several meters from any
reproduces the actuator local control
angle. In addition, it is possible to
in the field can be shared with your PC
panel for easy control of the automated
connect to any F02 with optional
in the office through the PC Manager
package and offers several tools for a
Bluetooth within operating distance
Software
complete analysis of the actuator status
with on pda
PC Manager
PC Manager transforms your Pc into a
actuator status. F02 supports
C Manager software supports
strong tool for the control, set-up and
Bluetooth non-intrusive
Bluetooth and usB communication
diagnostics of F02 actuators. A user
communication. The same graphic
Windows 2000 and XP operating
friendly graphic interface reproduces the
interfaces that are available with Pda
systems)
actuator local control panel for easy
Manager are used with pc manager
control of the valve and offers several
and are easily synchronized with the
tools for a complete analysis of the
PDA
Copyright 2007 Tyco Flow Control. All rights reserved
BIFMC-0472
5
BIFFI F02 Electric Actuator
Models F063 to F2KO
Models f063,F125,F250,F500,F1K0
R
G
E
BF卩
M
W
力
D1
With optional local interface module oM3
Dimensions (inches)
Weight
Model a
A1
D D1
E
F
H
K
L
M
N
P
W2(bs)
F0639.411.310.78.34.56.33.34.72.73.12.51.31.42.62.749691"NPT16.5
F1259411.310.7904.56.33.34.72.73.12.51.32.13.4344.9691"NPT19.8
F25011.613.413.111.35.16.94.36.12.73.73.01.32.53.7367.19.11"NPT34.2
F50011.613.413.111.35.1694.36.12.73.73.01.32.53.73.67.19.11"NPT37.5
F1K013.415.313.714.35.57.34.36.82.74.1321.3556.86.59.59.11"NPT57.0
Notes
1. Space required for cover removal
2. 4 total conduit connections
3. Add 1.1 lbs for Option Module OM3 Local Interface
Copyright 2007 Tyco Flow Control. All rights reserved
B|FMC-0472
BIFFI F02 Electric Actuator
Models F063 to F2KO
Model F2Ko
R
W
P
江f
N
L M C
W
K
H
With optional local interface module OM3
Dimensions(inches)
Weight
Model a
A1
B
D D1
E
G H
J
K
L
M
N P R W2(bs)
F2K013415319.918.35.57.310.5682.74.1321.39510.710.49.59.11″NPT99.2
Notes
1. Space required for cover removal
2. 4 total conduit connections
3. Add 1.1 lbs. for Option Module OM3 Local Interface
Copyright 2007 Tyco Flow Control. All rights reserved
BIFMC-0472
7
BIFFI F02 Electric Actuator
Models F063 to F2KO
EN ISO 5211 Mounting System
The biffi fo2 uses the internationally
recognized iso 521 1 as a standard for
mounting. This provides interchangability
ith existing valve top works and
actuators in the field
Biffi has again taken an additional step
with the new F02 and provided not only
dual mounting bolt circles but dual shaft
configurations. Every actuator comes
ith a dual keyed shaft bore as well as
an inserted star drive adaptor This
lows coverage of more valve sizes and
ypes with fewer actuator models
A
Actuator Base
Dimensions(inches)
Standard bore 1
Bolt c|rc|e2—
Standard Bore insert
B
Flange Di
Holes
Flange Dia
Holes
Star Drive
Model Dia
Key
Depth
Code
Code
Square [mm] depth
1.1251/4X1/4
1.34
F05
M6
F07276
M8
17
1.34
F125
2.12
F07
2.76
F10
M10
22
2.12
F2501.8751/2X3/82.12
F10402
M10
4.92
M12
27
2.12
F5001.8751/X3/82.12
F10402M10
F124.92M12
27
2.12
F1K02.2501/x3/8
4.80
F10
4.02
M10
5.51
M16
1.57
F2K02.2501X3/84.80F12492M12F166.50M20
36
1.57
Notes
1. Standard bore for the model f 125 is 35 mm
ith 10 mm x 8 mm key
2. F250 units with serial number before
064519E18030 have 35 mm bore and three
bolt circles. F07.F10 and F12 Insert is
22 mm star
Copyright 2007 Tyco Flow Control. All rights reserved
B|FMC-0472
BIFFI F02 Electric Actuator
Models F063 to F2KO
Performance
Adjustable torque and stroke time offers
flexibility in performance and valve
protection unsurpassed in the small
electric quarter-turn market
Torque output at selected setting(Ib in.)
Model
100%
40%
F063
600
560
520
480
440
400
360
320
240
F12513001214
1127
1040
954
867
780
693
607
520
F250
2500
2334
2167
2001
1834
1667
1500
1334
1167
1000
F500
5100
4761
4421
4081
3741
34013061272023802040
9100
8496
7282
606
5461
4854
4247
3640
F2K017700165251534414164129831180210622944182617080
Position
Output torque is independently adjustable from 40% to 100% in both directions of travel. Adjustments are in increments of 1 from o to 9. the default setting is
100%, position 9 on the rotary selector used for configuration
Operating Time at selected setting(secs/90)
100%
10
F063
12
15
38
48
60
75
110
F125
12
15
38
75
110
F250
12
15
38
60
75
110
F500
12
15
38
8
60
7
110
F1Ko
100
120
140
180
F2Ko
100
132
220
264
310
400
Position
9
5
for the F063, F125, F250, AND F500-30 seconds for the F1Ko-and 66 seconds for the F2KO. the tolerance is +/-10% of nomine settings are: 18 seconds
Output speed is adjustable from 10% to 100% in both directions of travel
ustments are in increments of 1 fromo to 9. the defaul
Copyright 2007 Tyco Flow Control. All rights reserved
BIFMC-0472
9
BIFFI F02 Electric Actuator
Models F063 to F2KO
Current Draw
Model Fo63
Model f125
A
A
6.50
6.50
6.00
5.50
4
4.50
5050505
3.75
2.50
24 VAC
2.00
11111111
.60
1
50020002430
24 VDC
aVA
04000008000
120 AC
120 VAC
240VAC
120VDC
0.20
240VCC
210 VDC
0.05
time(sec/90
me(sec/90)
8121522304050607590
8121522304050607590
Model F250
Model F500-F1K0-F2Ko
16
15
109876544
A000000000000
98877
544
050505050
100
24 VDC
32222
111
48 VAC
24 VAC
4.0
00000
000
120 VAC
40VD
time (sec/90%)
tme(Sec/90°)
8121522304050607590
8121522304050607590 Models500
52430456090100120150190 Model1KD
Notes
35610132102306
1. A= current draw(Amp)at nominal conditions(output torque 100%)
2. Max current(Amp)at stall conditions-12X A
3. Current diagrams for VDC supply
Current diagrams for VAC/1-phase supply
4. Power factor for VAC supply-060
Copyright 2007 Tyco Flow Control. All rights reserved
B|FMC-0472
10
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.