详细说明:ABB接触器1650A资料pdf,ABB接触器1650A资料AF1350/AF1650 3-pole Contactors
a.C./d.C. Operated -Wide voltage range
Electronic Coil Interface
o The most compact 1650A contactor
O Modern family design to match other ABB products
O Type 2 coordinated with breakers
O Electronic coil interface
O PLC operation possible
● CULus approved
O Low environmental impact thanks to Life Cycle Assessment
Applications
AF1350 and 1650 are modern and compact 3-pole contactors designed for heavy duty industrial applications
They are designed for carrying and switching both inductive (AC-3)and restive(AC-1) loads
High mechanical and electrical endurance make them suitable also for motor applications
Typical applications are as
Transfer switch or as main isolation contactor in generator sets
Main contactor for static power switching
Main or by-pass contactor in windmills
Main or by-pass contactor for frequency drives and softstarter
Y/D starters for example on board ships
The coil is electronically controlled with teatures such as wide coil voltage range, low pull-in value and low power
consumption to mention some of the features. It can also be operated with a low voltage signal directly from a Plc
These contactors are fully tested together with ABB breakers to meet type 2 co-ordination
For motor applications there is a three phase electronic overload relay called E1250 DU available
ABB
1SFC101005c0201
AF1350/AF1650 3-pole Contactors
Ordering details
Contactor (Terminal screws and fixing screws included
Rated operational
Type
Order code
Weignt
current
contacts
AC-1
AC-3
5<∠0°C400V
A
1350
860
AF1350-30-11
1sFL657001R7011
22
AF1350-30-22
1SFL657001R7022
AF1350/AF1650
1650
1050
AF1650-30-11
1sFL677001R7011
3500
22
AF1650-30-22
1SFL677001R7022
3500
Accessories
CAL 18-1
Auxiliary contact blocks (side mounting)
For contacto
T
Order code
type
blocks
八F1350,AF1650
cAL18-11
1SFN010720R10112
0.050
cAL18-11B1
1SFN010720R33112
0.050
1) CAL1B-11B is a bloc< for mounting outside a CAL-8-11 block
ZL1650
Main contact sets
For contactor
T
ype
Order code
Weignt
e
AF1350
ZL1350
1SFN166503R10001
2.500
AF1650
ZL1650
1SFN166703R10001
3.50
Arc chutes/De-ionizing plates
For contactor
T
Order code
Packing
Weignt
kg
AF1350,AF1650
ZW1650
1SFN166510R10001
4.000
ZAF1650
Coils
For contactor
Typ
Order code
Packng
type
g
AF1350,AF1650
ZAF1650
1sFN156570R70261
0.900
Printed circuit-board
For contactor
T
Order code
Packng
Weignt
AF1350,AF1650
zP1650
1SFN166521R10701
0.300
Mechanical interlocking of two horizontal mounted contactors
8For contactor
Type
Order code
set
|AF1350,AF1650
VM1650H
1sFN036503R10001
6
VM150
Electronic overload relay- class 10, 20, 30 selectable
For contactor
Order code
Packng
kg
AF1350,AF1650
E1250DU2
1SFA739001R10001
10
2) mounting kit with busbars for contactor mounting include
1250DU
4
ABB
1SFC101005c0201
AF1350/AF1650 3-pole Contactors
Technical Data
General Technical Data
Main pole- Utilization Characteristics
Contactor type
AF1350/AF1650
Contactor type
AF1350
AF1650
Rated insulation voltage Ui
Rated operational voltage Ue max V
1000
according to lEC 60947-4-1
1000
Rated frequency limits
Hz
25..400
according to UL/CSA
Conventional free-air thermal current Ith
Rated impulse withstand voltage
acc to IEC 60947-4-1
kV
ocen contactors9≤40
A1350
1650
Standards
with conductor cross-sectional area mn
9/00×513/100×51)
Devices complying with
Rated operational current I /AC-1
International standards EC 60947-1/60947-4-1 for air temperat ure close to contacto
European standards EN 60947-1/60947-4-1
e≤40
A1350
1650
UL508
U. max.1000V≤55%C
A1150
1450
0≤70°
A1000
Certifications- Approvals
∈⑤
with conductor cross-sectional area mm2 2//100x5 1) 3//100x5
Utilization category AC-3
Air temperature close to contact
fitted with electronic O/L re ay
-25to+70
Rated operational current le Ac-3
without electronic O/L relay
-4Cto+70
A860
1050
for storage
40to+70
A
1050
A860
1050
Operating altitude
≤3000
A860
105C
Rated operational power AC-3
Magnet System Characteristics
kW257
Contactor type
AF1350/AF1650
kW500
560
Rated control circuit voltage
( Ucmin. Uc max)
Rated making capacity AC-3
at 50 Hz
100.250
10×leAC·3
at 60 Hz
100..250
Rated breaking capacity AC-3
100
8×eAC-3
Coil operating limits
As cC
Short-circuit protection
Product coordinat on wih ABB
according to IEC 60947-4-1
0.85 x Uc min.1.1 x Uc max
circuit breaker. Please consult
Drop-out voltage in % of Uc min level
55%
information
Coil consumption
Rated short-time withstand current I
Average pull-in vaue 50 HZ VA
1900
at 40 C ambient temp., in free air
60 Hz
VA
1900
from a cold state 1s
A10000
12000
W
1700
103
A8000
1000
500
Average holding value 50 HZ VA/W
48/17
A6000
1 min
5500
60 Hz VA/W
A4500
48/
15 min
A1600
2200
d. c
W
16
Maximum breaking capacity
Operating time
A1-A2
A10000
12000
between coil energization and
O. contact closing ms
Heat dissipation per pole le /AC-1 W 80
N C. contact opening
le /Ac-3 W 50
50
ms
50..80
between coil de-energization and
Max electrical switching frequency
N○. contact opening ms
for AC-3
cycle
N.C. contact closing ms
for∧C2,∧C4
cycles/h
with Plc
Electrical durability
50000
between coil energization and
N O
ng ms
Mechi
N.C. contact opening ms
40
illions of operating cycles
between coil de-energization and
max. mechanical switching
cycles/h
N O. contact opening ms
10..30
frequency
N.C. contact closing ms
10..30
Dimensions of the bars
ABB
1SFC101005c0201
AF1350/AF1650 3-pole Contactors
Technical Data ul
Amp-rating for AF1350/AF1650
The"amp-rating value corresponds to the "General Use Rating" defined in specification UL508: the
operational current, bot during pull-in and steady-state conditions, must not exceed the"amp-rating
value of the device In alternating current, the inductive cos o of the load between 0.75 and 0.8.
Contactors
ain contacts
Auxiary contacts
(General Use Rating)
Nomil
Nominal
pilot duty
Nominal
Nominal
US LISTED
current
curren
ge
A
Vac
AF1350
1350
600
A600,Q30010
600
AF1650
1650
600
A600,Q30010
600
3-phase motor-rating
UL Approvals stipulate the following for contactors:
the 3-phase motor-rating": motor power(hp)and corresponding current (A)
the"amp-rating": usual operational current (A) and nominal voltage(v).
The technical characteristics figuring on devices must be respected and have been reproduced in the
table below
Contactors
Size
Motor power P(hp)and nominal current e(A)
NEMA
220∨/240V
440V/480V
550V/6C0V
y
A
h
AF1350
400954
800954
1000954
AF1650
8
4501030
9001030
11501050
ABB
1SFC101005c0201
Electronic overload relays E1250 DU
for contactors AF1350/AF1650
General technical data
Technical data of the conducting paths
Type
E1250 DU
Number of conducting paths
3
Standards
EC60947--1/EC60947-5-1
Setting range
A375.1250
imajor European and in: ernat onal standards) EN 60947-4-1/EN 60947-5-1
Approvals and certificates
〔∈
Tripping classes to
EC60947-4-1/EN60947-4-1
10, 20, 30 (adjustable)
Rated insulation voltage U V 69
Frequency range
Hz 50 and 60
Rated operating voltage U
v690
(only for a.C. operat ing 3 pnase)
Impulse withstand voltage U
kv 6
Load rating of auxiliary contacts
Permissible ambient temperature
Contact
Storage
°c-25to+70
NC(95-96)N(9798)
Operation
G-25to+70
Rated operating voltage U
6o0
Mounting position
Same as Contactor
Rated thermal continuous current A
6
6
AF1350/AF1650
Rated operating current I
Mounting
by screws: 4 X M6
at AC-15 230 V
3
al
1.1
Connection terminals and attachment type
at Ac-15 500V
AAAAAA
0.9
0.9
Auxiliary contacts
at AC-15 690 V
0.7
0.7
Screw terminal(screw size
at DC-13 24V
15
with self-disengaging clamping piece
M3.5
at DC-13 60V
0.5
05
at DC-13 110V
0.4
Tightening torque
Nm 1
at DC-13 220 V
0.2
0.2
connection cross-sections
Short-circuit protection fuse gG A
single-core or stranded
mm22x0.75.
flexible with wire end ferrule
mm22×0.75.4
Connection terminals
Main conductors
Screw terminal(screw sze
M12
Protection degree acc to
EC60947-1EN60947-1
PCO
Description
The electronic overload realy(type E1250 DU) is available in the current range 375...1250 A. The E1 250 DU is a 3-phase relay intended for ac
circuits and is not suitable for single-phase or d rect current (d. c. crcuits. Tne reset of the relay can be done manually or automatically. Tripping
class can be set manually(class 10, 20 or 30). a busbar kit for mounting the E1250 DU to the AF 1350/AF1 650 contactor is included
Tripping curves for E1250 DU electronic overload relays
for e ectronic overload relay E1250 DU
100
I/Ie
0 Class 20 Class 30
423.9479
10
69139
5
Not suitable for single-phase and direct current(d. c )motors
1SFC101005c0201
AF1350/AF1650 3-pole Contactors
Dimensions and Drilling plans
Dimensions
Drilling plan
⊕十+10
135
392
312340
1312
24
、ForM841x)
AF1350/AF1650 Contactor
Dimensions
Drilling plan
244
(⊥二
T5一月一m
170
L:、了
For M6(4x)
136
395
10
AF1350/AF1650 Contactor +E1250 DU Electronic O/L relay
ABB
1SFC101005c0201
AF1350/AF1650 3-pole Contactors
Dimensions and Drilling plan
PLC Wiring and mounting positions
Dimensions
○○
879
10
256
Qcu-o=-Ouo
AF1350/AF1650 contactor VM1650H mechanical interlock
Drilling plan
136
136
312
二一
Control with logic control signals
When used with switches the wiring can be done as below
When used with transistor outputs the wiring can be done as below
+24V
Supply voltag
Supply voltage
+24V
X5 Contactor
X5 Contacto
Stop_ n
OFF N
COM
COM
Note: Emergency stop should disconnect Al and A2
Note: Emergency stop should disconnect Al and A2
Mounting positions
odom[oa
ABB
1SFC101005c0201
A Comprehensive product portofolio
Ag AF, 3-pole Contactors
Ty
pes
3-Pole A9 A12 A16
A26A30A40
A/AF50 A/AF63 A/AF75AAF95 A/AF110
IEC
3.
11
Thermal/Electronic
1.0
overload relay
Au
uxiliary contact
(Up to AAF110
block
Timer
Interlock
A. EK. 4-pole Contactors
Types
4-Pole
A9
A16
A26
A45
A50
A75
IEC
10
ABB
1SFC101005c0201
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.