您好,欢迎光临本网站![请登录][注册会员]  
文件名称: ATV21 MODBUS.pdf
  所属分类: 其它
  开发工具:
  文件大小: 754kb
  下载次数: 0
  上传时间: 2019-10-14
  提 供 者: weixin_********
 详细说明:ATV21 MODBUSpdf,ATV21 MODBUS1. Important Information NOTICE Read these instructions carefully, and look at the equipment to become familiar with the device before trying to install, operate, or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure A The addition of this symbol to a danger or Warning safety label indicates that an electrical hazard exists, which will result in personnal if the instruction are not followed A This is the safety alert symbol. It is used to alert you to potential personal injury hazards obey all safety messages that follow this symbol to avoid possible injury or death A DANGER DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death, serious injury, or equipment damage ∧ WARNING Warning indicates a potentially hazardous situation, which, if not avoided, can result in death, serious injury, or equipment damage A CAUTION CAUTION indicates a potentially hazardous situation, which, if not avoided, can result in injury or equipment damage PLEASE NOTE Electrical equipment should be serviced only by qualified personnel. No responsibility is assumed by Schneider Electric for lences arising out of the use of this material. this document is not intended as an instruction manual for untrained persons. any o 2006 Schneider Electric. All Rights Reserved 2. Before you begin Read and understand these instructions before performing any procedure with this inverter, in order to completely and correctly utilize excellent performance of this unit. Besides this user manual, you will find in the chapter "Documentation structure"which manuals we advice you to read to develop software communicating with Altivar 21 If you need support, please contact our sales offices After reading this instruction manual, please keep it handy for future reference A DANGER HAZARDOUS VOLTAGE Read and understand the installation Manual before installing or operating the Altivar 21 inverter Installation, adjustment, repair, and maintenance must be performed by qualified personnel. The user is responsible for compliance with all international and national electrical standards in force concerning protective ground ing cfa‖ equipment Many parts of this variable speed drive, including the printed circuit cards, operate at the line voltage. DO NOT TOUCH Use only electrically insulated tools DO NOT touch unshielded components or terminal strip screw connections with voltage present. DO NOT short across terminals Pa and Pc or across the dC bus capacitors Install and close all the covers before applying power or starting and stopping the inverter Before servicing the variable speed drive Disconnect all power Place a DO NOT TURN ON" label on the variable speed drive disconnect. Lock the disconnect in the open position Disconnect all power including external control power that may be present before servicing the inverter. WAIT 15 MINUTES to allow the dc bus capacitors to discharge. Then follow the dc bus voltage measurement procedure given in the Installation Manual to verify that the dc voltage is less than 45 VDC. The inverter LEDs are not accurate indicators of the absence of dc bus voltage Electric shock will result in death or serious injury. A CAUTION DAMAGED EQUIPMENT Do not install or operate any inverter that appears damaged Failure to follow this instruction can result in injury or equipment damage 3. Introduction Thank you for purchasing the Altivar 21 inverter equipped with an embedded Modbus port The present guide contains information about the installation of the altivar 21 inverter on a Modbus network and describes the Modbus services available o y using the Modbus port of the Altivar 21, data communication can be made with a PLC, a host computer or other devices via a Modbus B etwork Data exchanges give access to all Altivar 21 functions Control (start, stop, reset, setpoint), Monitoring(status, current, voltage, thermal state.), Diagnostics(alarms), Configuration The communication port has an RJ45 connector for the connection to the network. At the physical layer, it supports 2-wire R$485 and transmission speed at 9600 or 19200 bps 4 Modbus functions are available (16#03)Read Holding Registers 6(16#06)Write Single Register 16 (16*10)Write Multiple Registers 43/14 (16#2B/0E)Read Device Identification Function 3 has a restricted implementation with length 1 Read one word"), it permits to read any parameter of the inverter, one by one with lengths 2 to 5("Read indirect block"), it permits to read a particular block of 2 to 5 indirect parameters. These 5 parameters can be configured through the operation panel to relevant monitoring parameters Function 16 has a restricted implementation with length 1 Write one word), it permits to write any writable parameter of the inverter, one by one with length 2(Write indirect block"), it permits to write a particular block of 2 indirect parameters. These 2 parameters can be configured through the operation panel to relevant control parameters 4 Documentation structure ■ Modbus atv21 manual This manual describes Connection to the network Configuration of the communication- related parameters Modbus services supported Parameter list ( additional to the ATV21 user manual) YouwillalsofindimportantinformationinotherAltivar21technicaldocuments.theyareavailableonthewebsitewww.telemecanique.col and on the cdrom delivered with each inverter. ■ATV21 user manual This manual describes How to assemble the inverter How to connect the inverter The functions and the parameters of the inverter, How to use the operation panel You will find in this manual the address and possible values of the parameters of the inverter Note: In both manuals, the address of the parameters is named"Communication number"and coded in hexadecimal (16 # 5. Connection to the network 5. 1. Connection to the inverter Connection accessories should be ordered separately(please consult our catalogues) Connect the rj45 cable connector to the modbus connector Pin out of the modbus connector View from underneath Pin signal Reserved Common(common of the signal and power supply) Reserved D1 Modbus name)or B(EIA/TIA485 name) DO (Modbus name)or A(ElA/TIA485 name Reserved 24 V supply(for RS232/RS485 converter or remote terminal) 8 Common(common of the signal and power supply) A WARNING DAMAGED EQUIPMENT Use wiring cables or taps that connect only signals DO, D1 and common. Refer to Telemecanique catalogue or to5.2 Connection via RJ45 wiring system". Failure to follow this instruction can result in injury or equipment damage A WARNING DAMAGED DEVICE If a converter or a terminal is connected to the rj45 connector using the power supply on pin 7 and 8, check that the voltage(24V)of this power supply is compatible with the converter or the terminal. Failure to follow this instruction can result in injury or device damage 5. Connection to the network 5. 2. Connection via RJ45 wiring system 1 Master(PLC, Pc or gateway) 2 Modbus cable depending on the type of master(see table 3 Modbus splitter block LU9 GC3 4 6 5 4 Modbus drop cables v3 A8 306 Re 5 Line terminators vw3 A8 306 RC 6 Modbus T-junction boxes W3 AB 306 TFee(with cable 7 Modbus cable(to another splitter block) TSX CSA.00 AIV31 Connection accessories Description Reference Modbus splitter block 10 RJ45 connectors and 1 screw terminal LU9 GC3 Modbus T-junction boxes With integrated cable(0.3 m) VW3 A8 306 TF03 With integrated cable(1 m) VW3 A8 306 TF10 For rj45 connector R=120,C=1nF VW3 A8 306 RC terminators R=150(specific to 2-wire Jbus schematic", page 45) VW3 A8 306R ■ Connecting cables Description Length Connectors Reference Cables for 1RJ45 connector and 1 stripped end VW3A8306D30 Modbus bus 0.3 2 RJ45 connectors VW3A8306R03 2RJ45 connectors VW3A8306R10 2RJ45 connectors VW3A8306R30 RS 485 double 100 Supplied without connector TSX CSA 100 shielded twisted pair 200 Supplied without connector TSⅩCSA200 cables 500 Supplied without connector TSⅩcSA500 Type of master Master interface Modbus connection accessories for RJ45 wiring system Description Reference Twido Plc Adaptor or mini-DIN RS485 3 m cable fitted with a mini-din connector and an Rj45 TWD XCA RJ030 interface module connector Adaptor or screw terminal 3 m cable fitted with an Rj45 connector and stripped at the W3 A8 306 D30 RS485 interface module other end TSX Micro plc Mini-DIN RS485 connector 3 m cable fitted with a mini-din connector and an rj45 WD Xca rjo30 connector PCMCIA card(Tsx Stripped cable TSX SCP CM 4030 SCP114 TSX Premium Plc TSX sCy 11601 or Cable fitted with a sUB-D 25 connector and stripped at the TsX SCY CM 6030 SX SCY 21601 module other end (for connection to the screw terminals of the SUB-D 25 socket) LU9GC3 splitter block) PCMCIA card (TSX Stripped cable TSX SCP CM 4030 SCP114 Ethernet bridge Screw terminal RS485 3 m cable fitted with an RJ45 connector and stripped at the W3 A8 306 D30 (TSXETG 100) other end Profibus dP gateway RJ45 RS485 1 m cable fitted with 2RJ45 connectors W3P07306R10 (LA9P307 Fipio(LUFP1)or RJ45 RS485 0.3 m cable fitted with 2 RJ45 connectors or WW3A8 306 R03 or Profibus DP(LUFP7) 1 m cable fitted with 2 RJ45 connectors or WW3 A8 306 R10 or 3 m cable fitted with 2 RJ45 connectors V3A8306R30 DeviceNet (LUFP9) Serial port Pc Male sUB-D 9 RS232 serial RS232/RS485 converter and TSX SCA 72 and port PC 3 m cable fitted with an RJ45 connector and stripped at the W3 A8 306 D30 other end (for connection to the screw terminals of the LU9GC3 splitter block) 5. Connection to the network 5.3. Connection via junction boxes 1 Master(PLC, PC or communication module 2 Modbus cable depending on the type of master 3 Modbus cable tsx csaoo0 25 3 4 Junction box TSX SCA 50 5 Subscriber sockets TsX sCA 62 6 Modbus drop cables vw3 A8 306 7 Modbus drop cable vw3 A8 306 D30 ATV 31 Connection accessories Description Reference Junction box s×SCA 3 screw terminals and an Rc line terminator, to be connected using cable VW3 A8 306 D30 Subscriber socket SX SCA 62 2 female 15-way SUB-D connectors, 2 screw terminals, and RC line terminator, to be connected using cable W3 A8 306 or VW3 A8 306 D30 ■ Connecting cables Description Length Connectors Reference Cables for modbus bus 3 1 RJ45 connector and one stripped end VW3A8306D30 1 RJ45 connector and 1 male 15-way SUB-D connector for TSX SCA WW3 A8 306 RS 485 double shielded 100 Supplied without connector TSX CSA 100 twisted pair cables Supplied without connector SX CSA 200 500 Supplied without connector TSX CSA 500 Type of master Master interface Modbus connection accessories for junction boxes using screw terminals Description Reference Twido plc Adaptor or screw terminal Modbus cable SX CSA100 or RS485 interface module X CSA200 or TSⅩCSA500 TSX Micro Plc Mini-DIN RS485 connector port Junction box TSⅩPACC01 PCMCIA card (TSX SCP114) Cable fitted with a special connector and TSX SCP CU 4030 stripped at the other end TSX Premium Plc TSX SCY 11601 or Cable fitted with a sUB-D 25 connector and TSX SCY CM 6030 TSX SCY 21601 module stripped at the other end SUB-D 25 socket) PCMCIA card (tsX SCP114) Cable fitted with a special connector and TSX SCP CU 4030 stripped at the other end Ethernet bridge Screw terminal rs485 Modbus cable TSⅩCSA100or (TSXETG 100 SX CSA200 or TSX CSA500 Profibus dP gateway RJ45 RS485 3 m cable fitted with an rj45 connector and VW3 A8 306 D30 (LA9P307) stripped at the other end Fipio(luFP1or RJ45 RS485 3 m cable fitted with an rj45 connector and V3 A8 306 D30 Profibus DP(LUFP7)or stripped at the other end DeviceNet (LUFP9)gateway Serial port PC Male 9-way SUB-D RS232 RS232/RS485 converter and TSX SCA 72 and serial port PC Modbus cable TSX CSA100 OI TSX CSA200 TSX CSA500 5. Connection to the network 5. 4. wiring recommendations Use telemecanique-approved cables and wiring accessories to ensure good transmission quality(matched impedance, immunity, shielding connection, etc. Keep the Modbus cable away from the power cables( 30 cm minimum Be sure to cross the Modbus cable and the power cables at right angles Whenever possible, connect the bus cable shielding to the protective ground, e.g., to the ground of each device if this ground is connected to the protective ground Install a line terminator at both ends of the line Ensure the correct line polarization. For more information, please refer to the technical publication "Electromagnetic compatibility EMc- Practical installation guidelines (deg99ggb.pdf).yoUcandownloadthismanualtromTelemecaniquewebsitewww.telemecanique.com 5. 5. RS485 wiring diagrams The characteristics and accessories mentioned in this section comply with the Modbus standard: "Modbus over serial line- Specification and implementation guide. Other non-Modbus-standard RS485 wiring diagrams are possible Please see the appendix for further information The latest generation of Telemecanique devices conform to Modbus(2-wire RS485) Main characteristics, Maximum length of bus 1000 m at 19 200 bit/s Maximum number of stations 32 stations, i. e 31 slaves(without repeater
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 相关搜索: ATV21MODBUS.pdf
 输入关键字,在本站1000多万海量源码库中尽情搜索: