详细说明:酷马Q9000英文版说明书pdf,酷马Q9000英文版说明书ma
www.chgma,com
7.51/ F Control method[ Fixed curve0E]………………………37
7.66 Parameter Group….,.,.,..….,….39
7.7 T Parameter Group........,….,….,…,……,….240
7.8 Parameter Group
··········.===·==··=···
7.81 Detection Act Description of Frequency Detection Relationship
57
7. o Parameter grou
60
7.91 Set value list of multifunction Input/ Output terminals
普,,鲁
63
7.92 Set values before Leaving Factory……
…64
7.93 The list of Specification Parameters...,.,.,.,.……….265
7.94 The list of Simple Parameters
……66
8. The description of malfunction and countermeasures of the frequency converter. 79
8. 1 External braking resistor selection....
83
8.2 External physical dimension of converter
84
9. Form of standard specification………
85
440 V Grade Spccification List
85
Oma
Www. ChqmA. co
1. Product Introduction
Thank you for purchasing Q-9000 Current Torquc Vector Control Gcncral-Purposc Invcrtcrs
developed by Qma Technical Company, featuring high performance and low noise. Please read this manual
thoroughly and carefully to make good use of the performance and functions of this inverter and to keep your
safety in operation. Please contact our agents in your regions or technical personnel of engineering
departnent in our company if any problem you cant solve by referring to the manual occurs in operation
Our professionals are ready to hell
You are welcome to use our products
[Notice]
Danger"Caution"in the manual prospect you the security precautions in moving, installing
operating and checking
[Danger ]: The misuse may lead to personal injury. Please don' t take down, install or change the internal parts
circuitries or links of the inverter without permission
[Caution]: The misuse may lead to the damage of the inverter or mechanical system
Danger]
Please dont touch circuit boards, parts or components after power-off before the"Charge
led is off.
Please don't take down, install or change the internal parts, circuits or links without
permission in the inverter
Please don't take wiring when power is supplied please dont check the components, parts
or signals on the circuit board when the inverter is running
Please correctly ground the earth terminals of the inverter: 220V terminal: the third
grounding; 440V: special grounding
[Caution]
Please dont carry on withstand voltage test on internal parts or components of the inverter,
because these semi-conduct parts or components are subject to be damaged by high
You mustn't connect the output terminals of the inverter U,v, w to the input terminals AC
(R,S,
Pleas dont touch the main circuit board for the CmosiC component on the circuit board
of the inverter is subject to affected or damaged by static electricity
[Security Precaution in Operation
Danger
Please don' t take off the front cover when the inverter is powered for fear of electric shock
Please don' t approach to the machine if you set the automatic restart function, because the motur
will be restarted after the machine stop
The" Stop"switch function is available after setting. It is different from urgent"Stop"switch in use,
pleas
It
Caution
Please dont touch the hot components such as radiator and brake resistor for fear of scald and
ectric shock
Plcasc input the permissible range of the motor and the machine, bccause it is casy for the inverter to
rise speed from low to high
Please pay attention to the relative settings when using the brake
Please don't test the signal on the circuit board when the inverter is running
Please dont discretionarily adjust the parameters, because the inverter was set well before leaving
facto
( ma
www.chgma,com
2. ProductⅠ spectio
Every Q-7000-EC inverter has passed function test before leaving factory. The clients should carry out the
following check steps upon delivery and unsealed
If the type and capacity of inverter are the ones you want
If the inverter was damaged during delivery, if so, please dont power it;
Plcase inform the local agents, technical personnel of Qma Technical Company for any above problem
Or contact service department for technical support. Thank you again for using our products
2. 1 Type description
Nameplate Information:(Example: AC220V, L15HP, 11KW-49A)
Type of the invert
MODEL:Q-9000-1144
(AC220V/LI5HP
Specification of input voltage
Inverter Vollage Grade
SOURCE: 3PH AC220V 50/60HZ
122 I. 220V Grade
Specification of output voltage
Series no
OUTPUT: 3PH AC0-230V 11KW49A1144 H: 440V Grade
SER. NO
3. Installation and Use
3. 1 Operating Environment
The installation environment,, which has direct influence the functions and service life of the inverter
should meet the following conditions
environmental temperature: Panel inner opening:(+10-45C/+14-113F)
Prevents from rain and moisture
Avoids direct sunlight
Prevents from oil spray or corrosion by salt
Prevents from corrosive liquid or gas
Prevents from the invade of dust, batt, and fine metal scraps
Be far away from radioactive substance and combustible substance
Prevents from EMI (from sealing machines or power machine for example)
Prevents from vibrations Plcasc usc shims to absorb librations if ncccssary
Several inverters are installed in a control board, please correctly lay out them for better heat emission. a
fan should be equipped to keep the temperature below 45.
The face of the inverter should face front for better heat ermission
The installation space must comply with relative regulations(It the inverter is installed in the control
board or the environment is permitted, the upper dust cover can be took off for better heat emission
Oma
www.chgma.com
4. Wiring Diagram
4. 1 Basic Wiring Diagram
Braking resistance(optional)
CCB
Motor
Thrcc phases input powor
V(T2)
M
50/60r
Q-9000
E
FWD/Stop
The third type grounding
FWD
ocher+12
Power DV
MS1
ase B pulse input(+)i
JOG
Phase A pulse monitor input (+)
o Phase A pulic monitor input(
g Phase B pulse monitor Input (+)
o phase B pulse monitor input ( -)
MA
Multifunctional analogue cutput
AM
(Factor preset autput curren
Multifunctional analogue output
Moc·
(Factor preset output current
Shielding lcad terminal
etting
Abnormal joint outp
EB,SAC 250V 5Amax
EC.DC30V ma
FIC
unctional joint output
oV 5A max
factory preset running signal
Power for setting frequency
Multifunctional open collector output 1
Power for setting frequency
DC 40V 58mAmax
factory preset zero speed signal
unctional open collector output 2
The common terminal of the multifunctional
na harness
Note 3: refers to wiring display cables or doublet
cord and twisted pair cables
Note 4: a Only shield twist pair cable is used as signal cable
b. Max length of PG is 100m
C The turning direction of PG may beselected by parameter
61-05 and the factory preset value is the phase advancer
during the motor is running forward
al Blocks Wiring Diagra
CM E FIVFIC+15 MF1|Y2
EA EBEC
FWD REV EF RST MS1MS2JOG BX MV+ MOC MA+ RARC
ma
www.chgma,com
4.2 Terminal Blocks Wiring Diagram
Functions of terminal blocks of main loop
Terminal
Function
R
Terminals for power input of main loop
T
B1(P)
DC power source of main loop
(C+ positive voltage)
DC power source of main loop
(- negative voltage)
B2
Connection point of brake resistor
U—vw
Output terminals of the inverter
Functions of terminal blocks of main loop
Terminal
Functi
R
Terminals for power input of main loop
BI(P)
Connection point of brake resistor
DC power source of main loop (DC-negative voltage
Connection point of brake resistor
Output terminals of the inverter
E
Grounding terminal(Especially the third grounding)
RS TB(P)O B2 UV W
Take 15HP, 20HP as examples
R
INPUT
OUTPUT
Extemal brake resistor
6
Oma
Www. ChqmA. co
4.3 Control Loop Terminal Blocks Function Description
Functions of the control loop terminal blocks (leaving factory settings
Sort No
Name
Function of the terminal
Signal Level
FWD Forward/Stop
ON Forward, OFF Stop
REV Reverse/Stop
on Reverse, oFF Stop
EF External Fault Input on Fault, OFF Normal
A RST Fault reset
on Reset
Terminal ef-BX
g/MS7Main/Auxiliary speed
are multifunction DC24V, SInA
on Auxiliary frequency reference
terminal
optical coupling
a/MS2 Multi-terminal speed JON Multi-terminal speed reference
referring to
insulation
reference
2 available
T1-0l~T106
JoG Inching Reference on Run with inching method
BX External Stop Running oN Inverter stop output
CM Comnon Terminal Signal output when shortening with FWDBX
+15
Powcr sourcc for
Power sourcc terminal for spccd rcfcrcncc sctting, +15
+15V,20MA
speed reference +15v Ipower source
Power source for
Power source terminal for speed reference setting, -15
-1 speed reference -15v power source
15V.20MA
12
Power source for
Power source terminal for speed reference setting, +15
speed reference -15v power source
+12V20MA
G9 FIV
O-10V/100a% frequency
Main speed
0-10VQ20K9)
frequency reference -10-+10V/-100%-+100%frequency
10,+10V(20Kg)
4-20MA/100%frequency
4-20mA2(20.)
Accessorial
MFI Auxiliary frequency 0-10V:100% frequency
0-10VC209
referene
10-+10V/-100%-+100% frequency 01-03Input T3
0-20m^,(25092)
ov Common terminal
Thc spccd rcfcrcncc common terminal for terminal
FIV.FIC, and mFI
E STP terminal
Connect the shield of jacket of isolated twisted line
Ra Signals output during The terminal is connected during
Capacity of the
connection point
running
RC I(5A connection point running
AC250V 5A
Multifunction
DC30V 5A
YI Zero speed detection The lowest frequency is lower than 01-loutputT2
sIgni
51-09. LOW level
Y2 Speed arrival
Within +1% of the set frequency
Open set output,
below 48V
dctection
LOW Icvcl
50mAbelow
YC Common terminal of
lerminal y1y2
Ea Fault output signal
Grounding
EB EA-EC, A connection when fault EA-EC is off
ECEB-EC,B
EB-EC is on
AC2S0V 5A
connection
DC 30V 5A
point
M+ requency meter
output
0-10V/100% frequency
Multifunction
1(0-10v/100% current can be sct)
analog output
3 MOC Common terminal
l(T401,T403)0~+10VMax5%
20ma below
Multifunction
MA+ Output current control 5V/inverter determined current analog output
2(T404,T4061)
ma
www.chgma.com
4. 4 The application of peripheral equipment and precautions
Power source
Please pay attention to if the voltage is correct to avoid damaging the inverter
No-fuse switch must be installed between AC power source and inverter.
No-fuse switch
Please adopt no-fuse switch that meets the rated voltage and current of the inverter to control
ON/OFF. The inverter should be protected
Plcasc dont adopt no-fuse switch as RUN/STOP switch for the inverter
Residual current circuit breaker
Residual current circuit breaker should be added to avoid misact led by electric leakage and to
protect the safety ofoperators
Electromagnetic contactor
The electromagnetic contactor needn 't be used in general condition except being used in
external control or auto restart function after power break or brake controlle
Electromagnet contactor can not be used as RUN/STOP switch of the inverter
AC Reactor for improving the power
AC reactors can be added to improve the power of power source with large capacity(600KVa
and above) for inverters of 220V/440 15 Kw and below
Noise filter at input side
Noise filter must be added if inductive load is used in the peripheral of the inverter
Inverter
There is no phase sequence between terminal r, S, T on input power source terminal blocks
phasc change connection is availablc
Connect terminal U, v,w on Input terminal blocks to terminal U, v,w on the motor. If the
inverter is forward running but the motor is reverse running, you only need to exchange the
connection between two terminals ofu.v or w on the terminal blocks
Please dont connect AC power source to the terminal u, v, w on the terminal blocks to avoid
the damage of the inverter
The grounding terminal e should be connected correctly: 220V grades: the third groundin
440V grade: special grounding
Noise filter on the output side
Reduce the higher harmonics generated by the inverter to avoid affecting the communication
equipment around.
Motor
Please adopt three-phase inductive motor meeting capacity of the inverter
The value of the current when the all motors work at the same time should be less than the
capacity of the inverter if one inverter drives more than one motor
Please dont add to capacitance between inverter and motors
Invcrtcr and motor(s) should bc grounded respectively
The followings should bc abided by in cxtcrnal wiring. It should bc checked up if the wiring is correct
Tier wiring
(Control loop buzzer should not be used to check up the wring
(A)The loop wring of main power must be isolated and parted from other high voltage or power line with
large current to avoid the disturbance of noise
The inverter should use independent power source branch
The common noisc filter can not guarantee the cffcct.
The noise filter special for the inverter or isolating transformer should be equipped if the inverter
hares power source loop with other machines
transmission. To prevent noise transmission, please add to metal bushing on the loop and the hoise
The noise filter special for the inverter should be added to the main loop output side to restrain
distance apart from other lines conveying signal controlling machines should be moved than 30 cm.
Please take account of the voltage drop of the circuitry if the wire between the inverter and motor is
too long. The voltage drop between phase is (v)=w3 wire resistance( /km)xline length
(excurrent 10-. The amount of carrier wave should be adjusted according to the wiring distance.
ma
Www. ChqmA. co
Inverter and the distance
Less than 100 m
of wiring for the motor
Less than 50m
More than 100 M
Permitted carrier wave 15KHz and below 10 KHz and below 5KHz and above
Sctting valuc of
150
10.0
5.0
parameter 36-01
(B)The wiring of control loop must apart from main loop control wire and other high voltage lines or power
lines with large current to avoid noise disturbance.
The wiring terminal Ra, RC, ea, eB or EC (connection output)of control loop should be wired
apart from other terminals
To avoid noise disturbance and misact, the control loop should wired with shield isolating twisted
wires. The shield twisted wires should be connected to terminal E. The wiring distance should not
than 50 meter
(C) The grounding terminal should be correctly grounded: 220V grade: the third grounding; 440V grade
special grounding.
The grounding wiring should be according to awG the grounding wire should be as short as
poss
the grounding wirc should bc grounded scparating from othcr load with largc current(such as
welding machines, large power motors)
The grounding loop shouldnt be formed if several inverters are grounded at the same time
D) Please select the specifications of wires, the diameters of main power source loop and control loop
according to electrical engineering rules to guarantee security
(E)After the wiring, please check up the wiring quality such as if the wiring is correct, if the wires are
broken or damaged, if the screws of the terminals are turned tightly
4.5 Application Examples
This section introduces the functions and applying occasions of the inverter
Function
apply
Purpose
N
Occasion
Function Description
Relative
paramete
Common
11-03
wIre ire
occasion
Istop, one connection control the start, stop and forward/reverse run by wiring[ T1-01
Ipoint controls
forward/reverse run
Sclcction of Common
iclcct thc sourcc of Sclcct thc extemal terminals of thc inverter or controlled[21-01-02
operation signal occasion
control signal
by the numerical digit operator
T1-01-06
Setting of
Common
Reduce noise
The frequency of carrier wave of the inverter can be
calmer wave
occasion
regulated freely to reduce the metal noise of the motor 36-01-03
Showing the
Common
The motor rotation speed (rpm), machine rotation speed
load rotation
occasion
Show the run stratus((rpm)and machine leaner speed(m/min) can be shown 01-03
on the digital operator
ommon
In-operation occasion,
Provide run status
This signal is put out during the motor is running; the
signal output mechanical signal
signal will disappear after the mechanical brake is
T2-0l~03
brake
released and the inverter stop running.
Common
Zero-speed
when the output frequency is lower than the lowest
signal output Working
Provide run status output frequency, this signal is output to the extemal T2-01-03
machine
systen or control circuitry
Common
Spced arrival occasion,
Provide run staty
When the output frequency arrives at the set frequency
signal output
this signal is put out to the external system or the control T2-01-03
g
machine
circuitry.
Running
between the
Hold the rotation
The external running signals can'I provide upper and
upper limit and pumping
Ispccd of thc motor in lower limits, which can be specially set and adjusted in 42-01--02
lower limit of
the upper and lower the inverter when gain or bias occurs
the frequency
fro
cquenc
Setting
forbidde
Prevent from
Pumping
The inverter can't continuously run in the set forbidden
frequencies with fixed speed. You can set three sets of 43-01-04
reference
vibrations
forbidden frequcncics
Undervoltage Commor
Provide runni
The voltage at P-N end of inverter side. When the
I2-01~03
signal output occasion
SS
undervoltage is check up, this signal is put out to
external systcm or control systcm
Frequency
ommon
holding run
T10l~06
ccasion
I Pause the accel deco The output keeps invariable when the inverter speeds up
or down
Fault auto
After the fault is checked up the inverter can res
Air conditioner continuity and
restart
automatically when the cause of the fault is removed.P5-01
reliability of run. The restart can be set as 10 times