详细说明:酷马Q7000-IP英文版说明书pdf,酷马Q7000-IP英文版说明书9 Parameters instructio
9.1 Initial setting
9.2 Parameters of Function for application
35
9.3 Adjust With Parameter
9.4 Parameters of Instruction
9.5 Parameters of motor
9.6 Parameters of Interface Card
42
9.7 Parameters of Exterior terminals
9. 8 Parameters of Protection
9.9 Parameters of Manipulator.
9.10 Parameterms Relative to elevators
10 Dedicated Functions for elevators
10.1 Requirements and Functions of Driving Elevator
57
10.2 Running Sequence Example
10.3 S Word Curve running
10.4 Starting Torque Compensation
10.4.1 Common Operation
10.4.aDjustment Method
60
Appendix 1Parameter table……
Appendix 2 Exception Display and Disposal for Self-learning of PG Original Pulse. 65
Appendix 3 Boundary Dimension
66
Appendix sTandard Specification
1 Product introduction
Thank you for purchasing Q-7000-IP frequency converters. In order to enable users to make the
most of this frequency converter and ensure users' safety, please read this operation and service manual
carefully. When any problem beyond this manual is found during using, please contact local sales
agency or our technicians of engineering department. Our professional technicians delight in service
Please continue to use this product
Use Directions]
Frequency converters belong to electrical and electronic products. For your safety, "Danger"and
Caution"items prompt you to take safe precautions when moving. installing, operating and inspecting
frequency converters
Danger:
After powering off and before charge indicator light going out, please dont touch circuit board
and parts and components
Please don' t dismount and change inside connections or wiring and parts of frequency convert
Not carry out wiring during powering on, not check parts and signals on circuit board during
operation
Make sure earth terminal of frequency converters is grounded correctly. For 220V, use the third
grounding type, for 440V, use particular type
Caution:
Please don't perform any pressure test on inside parts and components of frequency converters,
ince semiconductor parts are subject to damage resulted from high pressure
Never connect output terminals(U, V, W) of frequency converters with input terminals(RIS\T
of ac power supply
Please not touch main circuit board, for parts and components on circuit board of a frequency
converter are susceptible to static electricity and breakage.
[Safe precautions for operation]
Danger
Not take off front cover of a frequency converter during powering on for keeping personnel from
injury caused by electric shock
stops, please not be close to the machine for keeping away from danger ically after its running
hen automatic restart function is set. the motor will restart autom
The function of stop switch is not valid until it is set. Since this switch is different with emer
gency stop switch in usage, please keep attention on its usage
Caution
In order to prevent personnel from electric shock and injury, not touch heating elements such as
The frequency converter is easy to run from low speed to high speed, please input allowable range
of the motor and mechanics
When using brake stoppers and so on, please keep attention to their relative setting about their
verters are correctly adjusted at ex works, please don' t adjust them at will All frequency con
Not check signals on circuit board of the frequency converter during runn
Caution
If frequency converters are damaged or lack of parts and components, never install them
There is danger in injury
2 Product Inspection
2.1 Check items
Items to be verified
Check method
Is there any difference with ordered product?
Please check style of name plate on lateral side of
EL-700-P
Is there any damage?
Check whole appearance and whether any damage
Is there any loose condition on fasteners such as If necessary, check them with a screw driver.
screws etc
2.2 Items on name plate
Internal standard produ
- MODEL: Q-7000-IP-1144
(AC440V/H15HP)
Input source
SOURCE: 3PHAC440V50/60HZ
OUTPUT: 3PH AC0-440V11KW27A
QmaeLectrIc(sHangHai)co.Ltdwww.chqma.com
3 Installation Wiring
3.1 USe Environment
Installation environment of a frequency converter has direct effects on its normal use and service
life so its installation environment must conform to the following
Environment Temperature: +10-45C /+14-113F, for open style inside board
Avoid rainwater and damp environment
Keep from direct exposure in sunshine, oil fog and salty corrosion, corrosive fluid and firedamp
cotton wool and metal chip invasion.
Keep away from radioactive and inflammable substances
Keep from electromagnetic interference(welding machine and dynamic machine)
Keep from vibration, if unable to avoid, please install absorbing pad to reduce vibration. For sev
eral frequency converters, please install them inside the control panel
Please take attention to positioning for heat dissipation. In addition, please add a fan for heat dissi
pation to make sure that environment temperature is below 45C. When installation, please make
he front face frontward for heat dissipation
Installation space must comply with specifications (If the frequency converter is installed inside
the panel or ambient environment allows, take off its dust-resistant upper cover for heat dissipa
tion and ventilation)
Caution
When moving, please support the bottom of the box.
cover is held the body will drop to
ot, causing injury possibly
Please install it on noninflammable metal plate, otherwise fire may occur
If several frequency converters are installed in the same control box, make sure that a cooling fan is
placed and air temperature at inlet is below 45 C. Overheat may cause fire and other dangers
3.2 Installation Direction and Space
For excellent cooling effect on EL-700-IP, make sure installation direction is vertical
External dimensions and installation dimensions of the product refer to appendix3 "External
Dimensions
Air inlet temperature of the frequency converter must be controlled within the following range
Installation inside the box:-10+45 C
Charging part jumps over front face of the frequency converter Control box for installing the fre
quency converter must have sufficient depth dimension to set aside space, and built-out iso-
lation must be designed so that electric part can't be touched directly
3.3 Wiring
Before wiring, make sure that input power is off.
Electric shock and fire risk exists
Wiring should be carried out by an electric engineer.
Electric shock and fire risks exist
fter Emergency stop loop is connected, be sure to check its action(wiring is within users'respon-
sibility)
Injury risk exists
Caution
Make sure power voltage on main DC loop is consistent with rate voltage of the frequency con
verter Injury and fire risks exist
Never carry out voltage test on the frequency converter, which may cause damage on semiconduc-
tor etc
Please follow wiring diagram to connect braking resistance. Fire risk exists
Please use a torque-specified screw driver to fasten terminals. Fire risk exists
3.3. 1Method to connect main loop and control loop on EL-700-IP
king Resistance
Motor
人a
Q7000-IP
Reverse running/stop
External anomal
EF
nomal undo ing
(¥地
Multi-function inp
LEyn Mut-octn nagy outlput
External frc
Mck-___------(Set output current at ex works.
Common signal input terminal
Connection terminal for shielded linc
Powcr for frcqucncy
150r
O--10V Main velocity comman
d}篮丽m
0-+20mA Main vclocity
oma Mutlti-function analoGy FIC
set polar output (Set velocity-consisten
enals
2器N
ct polar output2( Set velocity-consistont
Power for frcqucncy sctting
+12 coma
-ls(imA
Common Multi-function open set polar output terminal
Notel: Interval stranded wirc
fote]: terminal platform +15, +12, .-15, 20mA
CME FIY FIC+15 MET OY Y1 Y2 Yc -15 EA EB FC
FWD REV EF RST MS1 MS2 JOG EX MY+ MOCMA+ RARE
6
3.3.2 Wiring on main lo
anger
Make sure to ground earth terminal (third grounding type)
Injury and fire risks exist
Caution
Never connect power line to output terminals (U,v,w)
Put voltage on output terminals will result in damage inside the frequency converters
I Notice about wiring at input side on main loop
1) Setting a circuit breaker for wiring
Make sure to connect a circuit breaker for wiring between supply power and junior main loop
(R,s, T)
2)Setting a residual current circuit breaker
If a residual current circuit breaker is connected on main loop, in order to prevent from wrong
action, please use a residual current circuit breaker which adapts higher harmonics as a counter
measure
3)Setting a electromagnetic contactor
The frequency converter can be available if there is no electromagnetic contactor at main side. If
a sequential controller is used to shut off main loop power instead of a circuit breaker for wiring,
the electromagnetic contactor may be used. However, if the electromagnetic contactor on main
side is used to stop the load forcibly, the regenerative brake won't work and free sliding stops
Since the electromagnetic contactor on main side is locked, it is not allowed to run or stop the
load. If a braking resistor element is used, use the hot protective relay contacts of the element to
build up a time sequence making the electromagnetic contactor off, otherwise the braking resis
tor may burn out when faults occur
4)Phase sequence of terminal block to be connected
Phase sequence of input power has nothing with that(r, s, t)of terminal block, so any terminal
can be connected
5)Setting a surge suppressor
If inductive loads(electromagnetic contactor, relay, coil and breaker etc) are connected around
o the frequency converter, please be sure to combine a surge suppressor
Forbidden to set a phase-lead electrolytic capacitor
In order to improve power factor and so on, if a phase-lead electrolytic capacitor and surge sup
inserted into in
de
op of the frequency converter, the
damage resulted from overhead caused by higher harmonic ingredients of the frequency con
verter, furthermore, the frequency converter will failure due to current
7) Setting a noise filter at main side
It is used to reduce higher harmonic noise from power line of the frequency converter
Wiring at input side on main loop
1)Wiring between a frequency converter and a motor
Connect its output terminals (Uvw) with motor's outlets (UVW). During operation, make
yere that the motor is running positively under the positive running command. If the motor runs
reverse order, choose and interchange two terminals among U.V.W.
Never connect power input line to output terminals
Never connect power input line to output terminals. If voltage is brought to output terminals,
inner apparatus of the frequency converter will damage
3) Setting a low-voltage manual switch
Even if the frequency converter is powered off, the motor continues to enable the load running,
please insert a low-voltage manual switch into input side of the frequency converter. During
maintenance and wiring troubleshooting, please keep the switch on
4) Never short and ground output terminals
Never touch output terminals directly or make output lines touched with outer shell of the fre
quency converter. Electric shock and short circuit risks exist. In addition, never short output
5) Never use a phase-lead electrolytic capacitor and noise filter
Never connect any phase-lead electrolytic capacitor and LC/RC noise filter in output loop Con-
nection with such components would make the frequency converter damaged, components burn
6) Never use a electromagnetic switch
Never connect any electromagnetic switch and contactor to output loop. If the frequency con
verter connects with the load during operation, it will result in over-current protection loop per
forming false operation due to surge current
7)Setting a hot protective relay
The frequency converter has overload protection function. If a hot protective relay is used
8)Installation of noise filter at output le (to choose motor protection as no motor protection)
lease set the parameter Pl-01 equal o(
Connecting a noise filter at output side of the frequency converter could reduce radio interfer
ence and induced interference
Induced interference: Electromagnetic induction makes signal line containing noise, resulting in
alse operation of control device
Radio interference: High-frequency electromagnetic waves generated by the frequency con-
verter itself and power cables make the radio give out noise during receiving signals
2) Countermeasure on induced interference
In addition to setting a noise filter as described above, all output lines are imported into a metal
tube could be used to inhibit induction at output side. Furthermore, when distance from signal
line is beyond 30cm, effects of induced interference reduce remarkably
10) Radio interference
Both the frequency converter itself and output
would generate induced interference, so
both input and output sides have a noise filter,
if the whole is screened with an iron box
radio interference would reduce. Furthermore, connection distance between the frequency con-
erter and motor should be as short as possible
3 Earth wiring
ge sure to use the third grounding type for earth wiring
Never share the same earth wire with welding machines and power plants.
Used earth wire should have a little bigger diameter than that specified in technical basic of
electrical equipments, and be as short as possible
Under the condition of using several frequency converters, please give attention to never
enabling earth wire formed a loop
4 Function of terminals on main loop
The following list shows functions of main loop terminals in their mark order, please refer to cor
rect target connectie
Functions of main loop terminal
Terminal
Function
R
Input terminal of main supply
Main DC Supply (dct positive vol
Main DC Supply (dc-negatice voltage
Connection point for braking resistance
U
Output terminals of the frequency converter
E
For
(The third gr
g type)
RsTB1OB2ulvw
Take example for 15HP and20HP
INPUT
OUTPUT
3.3.3Control Loop Wiring Method
Functions of control loop terminals are showed in the following list. Please choose proper terminals
1)Description on control loop terminals
Control Loop Terminal table
Signal Name
Description
Signal level
Mark
FWD Positive running-stop
Close" for positive running. " Open
REV Reverse running-stop"Close "for reversal, Open"for stop
EF External abnormal input"Close"for faults
aRET Abnormal fault reset Close"for reset
DC+24V 8mA
MS1 Multi-velocity com-
Closefor auxiliary frequency
Isolated photoele
cou
≌「MS2Muti- velocity com-Cose” to validate multi-veloc| terminals
Imand 2
ity setting 2
(T-01-T1-06)
JoG Inching command
Close for inching
BX External stop action "Close"for output stop of the fre-
COM Common terminal
+15 +15 power output +15V supply for analog command
15V20mA
power outpu
-15V supply for analog command
V 20mA
FIv Main velocity command -10V-+10V/-100%-+100%
10V~+10V(20KΩ)
0V~+10v/100%
V-10V, (20KS
阵-20mA/100%-10V~+10V/-100%~+100%
4-20mA,(2502)
a MFI Torque compensation -10V-+10V/-100%+100%Auxiliary analog input
for startup
0V~+10V/100%
0V~+10V(20K92)
OV Common terminal for
Close"at the end of"Close"at the end of torque compen-
Terminal capacity
RC torque compensation sation
elow ac250 1A
Multi-function Below DC250 1A
YI Null speed check output Close"under electrical level (22-01output terminals Open collector output
at null speed
(T2-01-T203) below+48V,50mA*
2 Consistent velocity
Close” within±2 Hz of setting fre
Check output
YC Common output termi
hal for YI and Y2
EA Fault output signal(lc EA-EB"closed"when faults occur.
terminal)
B-EC“open” when faults occur.
Below AC250V 1A
ault output
Below DC30V 1A
terminal)
ec Fault output signal(lc
terminal)
MV+ Consistent frequency
Multi-function analog 0-+10V max
(T4-01,T4-02)
MOC Common terminal
MA+ For monitoring output IoV/rated torque of fre-Multi-functior
(T4-04,T4-05)
2) Notice on control loop wiring
Control loop wiring should separate from main loop wiring(R, S,T,Bl, e, B2, U,V,W)and other
In order to prevent from interference and false operation, use shielded line to connect control
loop Wiring length should be limited within 50m
3.3.wIring Inspection
After wiring, be sure to check interactive connections. Never use singing function at this time
Is there any wiring mistake?
Do wire scraps and screws remain at electrical circuits?
Do thread ends of terminals touch with other terminals?