详细说明:施耐德以太网网络接口应用指南pdf,施耐德以太网网络接口应用指南Table of contents
Safety Information
7
About the book
9
Chapter 1 Introduction
,,,,,,,,,,,,,,,,11
At a glance
What Is a Network Interface Module
12
What Is Advantys STB?
STB NP 2212 Product Overview
19
Ethernet Communications and Connectivity
21
Chapter 2 The STB NIP 2212 NIM..............,.23
At a glance
External features of the stb nip 2212
24
STB NIP 2212 Network Interface
26
Rotary Switches
28
LED Indicators
The CFG Interface
.......33
The Power Supply Interface
35
Logic Power
37
Selecting a Source Power Supply for the lsland's Logic Power Bus
Module Specifications
42
Chapter3 Configuring the Island Bus∴∴
■■■■■■
45
At a glance...,,,,,,,,,,,,,,,,,,,,,,,,,,
45
Auto-Addressing...
6
Auto-Configuration
49
Installing the STB XMP 4440 Optional Removable Memory Card
Using the STB XMP 4440 Optional Removable Memory Card to Configure the
Island bus
The rst Button
RST Functionality
56
890USE177C0 September 2003
Chapter 4 IP Parameters.
At a Glance
How the stb nip 2212 Obtains P Parameters
.60
The iP Address assignment Process
Chapter 5 STB NIP 2212 Web Server
65
At a glance
5. 1 Introduction to the embedded web server
At a glance
66
About the embedded web server
67
Properties Web Page
70
5.2 Web Server Configuration Optior
71
At a gla
Configuration Web Page
Configuring an IP Address for the STB NIP 2212
Configuring Master Controllers
Master Configurator Web Page................... 80
Configuring a Role Name
5.3 Web Server Securit
At a glance
Web access password protection
.87
Configuration Password protection
90
5.4 Web Server Diagnostic Options
92
At a glance
92
Diagnostics Web Page
.......93
Ethernet statistics
.........94
STB NIP 2212 Registers Web Page
1O Data values Web Page
9
Island configuration Web age
....99
Island Parameters Web Page
Error Log Web Page
101
5.5 SNMP Services
103
At a glai
SNMP Device Management
..104
Configure SNMP Web page
106
about the schneider private mibs
.108
Transparent Factory Ethernet(TFE)MlB Subtree
110
Port502 Messaging Subtree
Web miB subtree
.,112
Equipment Profiles Sub
113
890USE17700 September 2003
Chapter 6 Data Exchange
115
At a glance
115
Data Exchange with the STB NIP 2212
116
Reading diagnostic Data
125
Modbus Commands Supported by the STB NiP 2212
133
Chapter 7 Connection Example
137
At a glance
137
Network architectu
139
Sample Configuration
Modbus Functions Supported by the stB NiP 2212
..,,..145
Chapter 8 Advanced Configuration Features
149
At a glance
149
STB NIP 2212 Configurable Parameters
Configuring Mandatory Modules
154
Prioritizing a module
What Is a Reflex Action?
..157
Island Fallback Scenarios
Saving Configuration Data
164
Protecting Configuration D
165
A Modbus view of the island's data Image
.166
The Island's Process Image Blocks
.169
The HMI Blocks in the Island Data Image
172
Glossary
175
Index
题■
■■■■■
191
890USE17700 September 2003
890USE17700 September 2003
Safety Information
Important Information
NOTICE
Read these instructions carefully, and look at the equipment to become familiar with
the device before trying to install, operate, or maintain it. The following specia
messages may appear throughout this documentation or on the equipment to warn
of potential hazards or to call attention to information that clarifies or simplifies a
procedure
A
The addition of this symbol to a danger or Warning safety label indicates
that an electrical hazard exists, which will result in personal injury if the
instructions are not followed
A
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death
DANGER
DANGER indicates an imminently hazardous situation, which, if not avoided, will
result in death, serious injury, or equipment damage
△ WARNING
WARNING indicates a potentially hazardous situation, which, if not avoided, can result
in death, serious injury, or equipment damage
△CAUT|ON
CAUTION indicates a potentially hazardous situation, which, if not avoided, can result
in injury or equipment damage
890USE17700 September 2003
Safety Information
PLEASE NOTE All pertinent state, regional, and local safety regulations must be observed when
installing and using this product. For reasons of safety and to ensure compliance
with documented system data, only the manufacturer should perform repairs to
components
When controllers are used for applications with technical safety requirements
please follow the relevant instructions
No responsibility is assumed by Schneider Electric for any consequences arising out
of the use of this material. this document is not intended as an instruction manual
for untrained persons
8
890USE17700 September 2003
About the book
At a glance
Document Scope This guide describes the common hardware and software features of the
Advantys STB network interface modules(NIMs) and those that are specific to the
STB NIP 2212. The specific features enable an Advantys STB island to function as
a node on an ethernet local area network( LAN)and, in turn, the Internet, or,
indirectly, a wide area network ( WaN)
The Ethernet LAN on which an STB NIP 2212 island resides uses Transport Control
ProtocolInternet Protocol (TCP/P)as its transport layer. The Modbus protocol runs
over the TCP/P layer. This way, an ethernet host device can control an island with
Modbus commands. The Modbus protocol allows devices that can connect only to
the RS-232 port on other Advantys STB NIMs to connect to the STB NIP 2212's
fieldbus port, too
Note: This Guide uses the module name stb nip 22 12 to introduce a feature
specific to the ethernet nim
The following information about Advantys STB NIMs in general and the
STB NIP 2212 in particular appears in this Guide
ts role as the Advantys STB Ethernet gateway
the NIM's integrated power supply and its role in the distribution of logic power
across the island bus
common external interfaces:
the two-pin connector to an external SELv-rated power supply
RS-232 interface to optional devices, including the Advantys configuration
software and a human-machine interface(HMI)operator panel
the optional removable memory card
advanced configuration features, such as island fallback scenarios
STB NIP 2212 specific features, including its global connectivity capabilities
how to configure an STB NIP 2212 with IP parameters
how to connect the stb nip 2212 to an ethernet network
STB NIP 2212 web-based configuration and troubleshooting features
Simple Network Management Protocol (sNMP) device management services
890USE17700 September 2003
About the book
Who should use this manual?
This manual is intended to support the customer who has installed the
Advantys STB island bus on an Ethernet LAN and needs to understand the
STB NIP 2212's local and remote communications capabilities
This manual assumes familiarity with the Modbus protocol
Validity Note
The data and illustrations found in this book are not binding. We reserve the right to
modify our products in line with our policy of continuous product development. The
information in this document is subject to change without notice and should not be
construed as a commitment by Schneider Electric
Related
Documents
Title of documentation
Reference number
Advantys STB System Planning and Installation Guide
890USE17100
Advantys STB Hardware Components Reference Guide
89oUSE17200
Advantys STB Configuration Software Quick Start Guide
89oUSE18000
Advantys STB Reflex Actions Reference Guide
890UsE18300
Transparent Factory Network Design and cabling Guide
49oUSE13400
Product Related Schneider Electric assumes no responsibility for any errors that may appear in this
Warnings
document. If you have any suggestions for improvements or amendments or have
found errors in this publication, plea
No part of this document may be reproduced in any fom or by any means, electronic
or mechanical, including photocopying, without express written permission of
Schneider Electric. All rights reserved. Copyright 2003
All pertinent state. regional and local safety regulations must be observed when
installing and using this product. For reasons of safety and to assure compliance
with documented system data, only the manufacturer should perform repairs to
components
When controllers are used for applications with technical safety requirements
please follow the relevant instructions
Failure to use Schneider Electric software or approved software with our hardware
products may result in injury, harm, or improper operating results
Failure to observe this product related warning can result in injury or equipment
damage
User Comments We welcome your comments about this document. You can reach us by e-mail at
TECHCOMM modicon com
10
890USE17700 September 2003
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.