您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 施耐德以太网网络接口应用指南.pdf
  所属分类: 其它
  开发工具:
  文件大小: 3mb
  下载次数: 0
  上传时间: 2019-10-13
  提 供 者: weixin_********
 详细说明:施耐德以太网网络接口应用指南pdf,施耐德以太网网络接口应用指南Table of contents Safety Information 7 About the book 9 Chapter 1 Introduction ,,,,,,,,,,,,,,,,11 At a glance What Is a Network Interface Module 12 What Is Advantys STB? STB NP 2212 Product Overview 19 Ethernet Communications and Connectivity 21 Chapter 2 The STB NIP 2212 NIM..............,.23 At a glance External features of the stb nip 2212 24 STB NIP 2212 Network Interface 26 Rotary Switches 28 LED Indicators The CFG Interface .......33 The Power Supply Interface 35 Logic Power 37 Selecting a Source Power Supply for the lsland's Logic Power Bus Module Specifications 42 Chapter3 Configuring the Island Bus∴∴ ■■■■■■ 45 At a glance...,,,,,,,,,,,,,,,,,,,,,,,,,, 45 Auto-Addressing... 6 Auto-Configuration 49 Installing the STB XMP 4440 Optional Removable Memory Card Using the STB XMP 4440 Optional Removable Memory Card to Configure the Island bus The rst Button RST Functionality 56 890USE177C0 September 2003 Chapter 4 IP Parameters. At a Glance How the stb nip 2212 Obtains P Parameters .60 The iP Address assignment Process Chapter 5 STB NIP 2212 Web Server 65 At a glance 5. 1 Introduction to the embedded web server At a glance 66 About the embedded web server 67 Properties Web Page 70 5.2 Web Server Configuration Optior 71 At a gla Configuration Web Page Configuring an IP Address for the STB NIP 2212 Configuring Master Controllers Master Configurator Web Page................... 80 Configuring a Role Name 5.3 Web Server Securit At a glance Web access password protection .87 Configuration Password protection 90 5.4 Web Server Diagnostic Options 92 At a glance 92 Diagnostics Web Page .......93 Ethernet statistics .........94 STB NIP 2212 Registers Web Page 1O Data values Web Page 9 Island configuration Web age ....99 Island Parameters Web Page Error Log Web Page 101 5.5 SNMP Services 103 At a glai SNMP Device Management ..104 Configure SNMP Web page 106 about the schneider private mibs .108 Transparent Factory Ethernet(TFE)MlB Subtree 110 Port502 Messaging Subtree Web miB subtree .,112 Equipment Profiles Sub 113 890USE17700 September 2003 Chapter 6 Data Exchange 115 At a glance 115 Data Exchange with the STB NIP 2212 116 Reading diagnostic Data 125 Modbus Commands Supported by the STB NiP 2212 133 Chapter 7 Connection Example 137 At a glance 137 Network architectu 139 Sample Configuration Modbus Functions Supported by the stB NiP 2212 ..,,..145 Chapter 8 Advanced Configuration Features 149 At a glance 149 STB NIP 2212 Configurable Parameters Configuring Mandatory Modules 154 Prioritizing a module What Is a Reflex Action? ..157 Island Fallback Scenarios Saving Configuration Data 164 Protecting Configuration D 165 A Modbus view of the island's data Image .166 The Island's Process Image Blocks .169 The HMI Blocks in the Island Data Image 172 Glossary 175 Index 题■ ■■■■■ 191 890USE17700 September 2003 890USE17700 September 2003 Safety Information Important Information NOTICE Read these instructions carefully, and look at the equipment to become familiar with the device before trying to install, operate, or maintain it. The following specia messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure A The addition of this symbol to a danger or Warning safety label indicates that an electrical hazard exists, which will result in personal injury if the instructions are not followed A This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death, serious injury, or equipment damage △ WARNING WARNING indicates a potentially hazardous situation, which, if not avoided, can result in death, serious injury, or equipment damage △CAUT|ON CAUTION indicates a potentially hazardous situation, which, if not avoided, can result in injury or equipment damage 890USE17700 September 2003 Safety Information PLEASE NOTE All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to ensure compliance with documented system data, only the manufacturer should perform repairs to components When controllers are used for applications with technical safety requirements please follow the relevant instructions No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. this document is not intended as an instruction manual for untrained persons 8 890USE17700 September 2003 About the book At a glance Document Scope This guide describes the common hardware and software features of the Advantys STB network interface modules(NIMs) and those that are specific to the STB NIP 2212. The specific features enable an Advantys STB island to function as a node on an ethernet local area network( LAN)and, in turn, the Internet, or, indirectly, a wide area network ( WaN) The Ethernet LAN on which an STB NIP 2212 island resides uses Transport Control ProtocolInternet Protocol (TCP/P)as its transport layer. The Modbus protocol runs over the TCP/P layer. This way, an ethernet host device can control an island with Modbus commands. The Modbus protocol allows devices that can connect only to the RS-232 port on other Advantys STB NIMs to connect to the STB NIP 2212's fieldbus port, too Note: This Guide uses the module name stb nip 22 12 to introduce a feature specific to the ethernet nim The following information about Advantys STB NIMs in general and the STB NIP 2212 in particular appears in this Guide ts role as the Advantys STB Ethernet gateway the NIM's integrated power supply and its role in the distribution of logic power across the island bus common external interfaces: the two-pin connector to an external SELv-rated power supply RS-232 interface to optional devices, including the Advantys configuration software and a human-machine interface(HMI)operator panel the optional removable memory card advanced configuration features, such as island fallback scenarios STB NIP 2212 specific features, including its global connectivity capabilities how to configure an STB NIP 2212 with IP parameters how to connect the stb nip 2212 to an ethernet network STB NIP 2212 web-based configuration and troubleshooting features Simple Network Management Protocol (sNMP) device management services 890USE17700 September 2003 About the book Who should use this manual? This manual is intended to support the customer who has installed the Advantys STB island bus on an Ethernet LAN and needs to understand the STB NIP 2212's local and remote communications capabilities This manual assumes familiarity with the Modbus protocol Validity Note The data and illustrations found in this book are not binding. We reserve the right to modify our products in line with our policy of continuous product development. The information in this document is subject to change without notice and should not be construed as a commitment by Schneider Electric Related Documents Title of documentation Reference number Advantys STB System Planning and Installation Guide 890USE17100 Advantys STB Hardware Components Reference Guide 89oUSE17200 Advantys STB Configuration Software Quick Start Guide 89oUSE18000 Advantys STB Reflex Actions Reference Guide 890UsE18300 Transparent Factory Network Design and cabling Guide 49oUSE13400 Product Related Schneider Electric assumes no responsibility for any errors that may appear in this Warnings document. If you have any suggestions for improvements or amendments or have found errors in this publication, plea No part of this document may be reproduced in any fom or by any means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric. All rights reserved. Copyright 2003 All pertinent state. regional and local safety regulations must be observed when installing and using this product. For reasons of safety and to assure compliance with documented system data, only the manufacturer should perform repairs to components When controllers are used for applications with technical safety requirements please follow the relevant instructions Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results Failure to observe this product related warning can result in injury or equipment damage User Comments We welcome your comments about this document. You can reach us by e-mail at TECHCOMM modicon com 10 890USE17700 September 2003
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: