您好,欢迎光临本网站![请登录][注册会员]  
文件名称: REF610_TRM_755310_ENh_IEC.pdf
  所属分类: 制造
  开发工具:
  文件大小: 1mb
  下载次数: 0
  上传时间: 2019-10-12
  提 供 者: weixin_********
 详细说明:ABB REF610 技术手册。该手册和操作手册共同为REF610所配套。1MRS755310 Feeder Protection Relay REF610 ssued:05.10.2004 Version: H/18. 11.201 Technical Reference Manual Contents Copyrights……, 7 1。 ntroduction…9 1.1. This manual 1.2. Use of symbols 1.3. Intended audience 1. 4. Product documentation 10 15. Document conventions 10 1.6. Document revisions 2. Safety information.……………13 3. Product overview 15 3.1. Use of the relay 1重■■着1面重1■ ∴15 3.2. Feature 15 4. Application……… 17 4.1. Requirements 17 4.2. Configuration 17 5. Technical description 21 5.1. Functional descript 21 5.11 Product functions 21 5. 1.1.1. Protection functions 21 5.1.1.2. Inputs 21 5.1.1.3. Outputs 22 5.1.1.4. Disturbance recorder 22 5.1.1.5. Front panel 22 5.1.1.6. Non-volatile memory 23 5.1.1.7. Self-supervision 23 5.1.1.8. Time synchronization ■■,■11 24 5.1.2. Measurements 25 5.1.3. Configuration 5. 4. Protection 27 5.1.4.1. Block diagram 27 5.1.4.2. Overcurrent protection . ...................27 5.1.4.3. Earth-fault protection . . ......... 29 5.1.4.4. Thermal protection for cables.....30 5.1.4.5. Phase discontinuity protection .........35 5.1.4.6. Circuit-breaker failure protection 35 5.1.4.7. Arc protection…… 36 5.1.48. Auto-reclose function 37 5.1. 49. Inverse definite minimum time characteristics 43 REF610 Feeder Protection Relay 1MRs755310 Technical Reference manual 5.1.4.10. Settings………,.57 5.1.4.11. Technical data on protection nctions 68 5.1.5. Trip-circuit supervision 5.1.6. Trip lockout function 74 5.1.7. Trip counters for circuit-breaker condition 75 5.1.8. Indicator LEDs and operation indication messages∴∴ .,75 5.1.9. Demand values∴ 75 5.1.10. Commissioning tests 76 5.1.11. Disturbance recorder 76 5.1.11.1. Function 76 5.1.11.2. Disturbance recorder data 5.1.113. Control and indication of disturbance recorder status 78 5.1.11. 4. Triggering 78 5.1.11.5. Settings and unloading 78 5.1.11.6. Event code of the disturbance recorder 79 5.1.12. Recorded data of the last events 79 5.1.13. Communication ports 81 5.1.14EC 60870-5-103 remote communication 5.1.15. Modbus remote communication protoco protocol 82 5.1.15.1. Profile of modbus 87 5.1.16. dnP 3.0 remote communication protocol...101 5.1.16.1. Protocol parameters....,.,,... 102 5.1.16.2. dnP 3.0 point list 102 6.1.16.3. DNP 3.0 device profile ..105 5. 1.16.4. Specific DNP features 112 5.1.17. SPa bus communication protocol parameters. 115 5.1.17.1. Event codes 5.1.18. Self-supervision(IRF) system 134 5.1.19. Relay parameterization 136 5.2. Design description 137 5.2. 1. Input/output connections 137 5.2.2. Light sensor input connections 143 5.2.3. Serial communication connections .143 5.24 Technical data 6. Application examples 155 6.1. Auto-reclose function 155 6.1.1. Fast tripping and initiation of shot 1 using two protection stages ..155 1MRs755310 Feeder Protection Relay REF610 Technical Reference Manual 6. 2. Fast tripping and initiation of shot 1 using start signals 156 6.1.3. Selecting adaptive sequence length 157 6.2. Arc protection 158 6.2.1. Arc protection with one REF610 relay 158 6.2.2. Arc protection with several REF610 relays...159 6.2.3. Arc protection with several REF610 relays and ne rEa101 160 7. Ordering information.………163 8. Check lists∴ 165 9. Abbreviations 171 6 1MRs755310 Feeder Protection Relay REF610 Technical Reference Manual Copyrights The information in this document is subject to change without notice and should not be construed as a commitment by abb oy abb Oy assumes no responsibility for any errors that may appear in this document. In no event shall ABB Oy be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document nor shall ABB Oy be liable for incidental or consequential damages arising from the use of any software or hardware described in this document This document and parts thereof must not be reproduced or copied without written permission from ABB Oy, and the contents thereof must not be imparted to a third party nor used for any unauthorized purpose The software or hardware described in this document is furnished under a license and may be used, copied or disclosed only in accordance with the terms of such license C Copyright 2011 ABB Oy All rights reserved Trademarks ABB is a registered trademark of ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of their respective holders Guarantee Please inquire about the terms of guarantee from your nearest ABB representative 8 1MRs755310 Feeder Protection Relay REF610 Technical Reference Manual Introduction This manual This manual provides thorough information on the protection relay rEF610 and its applications, focusing on giving a technical description of the relay Refer to the Opcrators manual for instructions on how to usc the human-machine interface(HMi)of the relay, also known as the man-machine interface(MMI), and to the Installation manual for installation of the relay 1.2 Use of symbols This publication includes the following icons that point out safety-related conditions other The electrical warning icon indicates the presence of a hazard which uld result △ The warning icon indicates the presence of a hazard which could result The caution icon indicates important information or warning related to the concept discussed in the text. It might indicate the presence of a hazard which could result in corruption of software or damage to equipment or property. The information icon alerts the reader to relevant facts and conditions The tip icon indicates advice on, for le, how to design your project or how to use a certain function Although warning hazards are related to personal injury, it should be understood that operation of damaged equipment could, under certain operational conditions, sult in degraded process performance leading to personal injury Therefore, comply fully with all warning and caution notices Intended audience This manual is intended for operators and engineers to support normal use of as well as configuration of the product. REF610 Feeder Protection Relay 1MRs755310 Technical Reference manual 1.4. Product documentation In addition to the relay and this manual, the delivery contains the following relay- specific documentation Table 1.4, -1 REF610 product documentation Name Document ID Installation Manual 1MRS752265-MUM Technical reference manual 1MRS755310 Operators manual 1MRS755311 1.5. Document conventions The following conventions are used for the presentation of material Push button navigation in the human-machine interface(HMI) menu structure is presented by using the push button icons, for example To navigate between the options, use4 and HMI menu paths are presented as follows Use the arrow buttons to select CONF'IGURAT'ION COMMUNICATION\SEA SETTINGS\ PASSWCRD SPA Parameter namcs, menu names, relay indication messages and rclay's HMI vicws are shown in a Courier font, for example: Use the arrow buttons to monitor other measured values in the menus DemAND VALUES and HISTORY DATA HMI messages are shown inside quotation marks when it is good to point out them for the user. for example When you store a new password, the relay confirms the storage by flashing ” once on the display
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: