文件名称:
REF610_TRM_755310_ENh_IEC.pdf
开发工具:
文件大小: 1mb
下载次数: 0
上传时间: 2019-10-12
详细说明:ABB REF610 技术手册。该手册和操作手册共同为REF610所配套。1MRS755310
Feeder Protection Relay
REF610
ssued:05.10.2004
Version: H/18. 11.201
Technical Reference Manual
Contents
Copyrights……,
7
1。 ntroduction…9
1.1. This manual
1.2. Use of symbols
1.3. Intended audience
1. 4. Product documentation
10
15. Document conventions
10
1.6. Document revisions
2. Safety information.……………13
3. Product overview
15
3.1. Use of the relay
1重■■着1面重1■
∴15
3.2. Feature
15
4. Application………
17
4.1. Requirements
17
4.2. Configuration
17
5. Technical description
21
5.1. Functional descript
21
5.11 Product functions
21
5. 1.1.1. Protection functions
21
5.1.1.2. Inputs
21
5.1.1.3. Outputs
22
5.1.1.4. Disturbance recorder
22
5.1.1.5. Front panel
22
5.1.1.6. Non-volatile memory
23
5.1.1.7. Self-supervision
23
5.1.1.8. Time synchronization
■■,■11
24
5.1.2. Measurements
25
5.1.3. Configuration
5. 4. Protection
27
5.1.4.1. Block diagram
27
5.1.4.2. Overcurrent protection . ...................27
5.1.4.3. Earth-fault protection . . ......... 29
5.1.4.4. Thermal protection for cables.....30
5.1.4.5. Phase discontinuity protection .........35
5.1.4.6. Circuit-breaker failure protection
35
5.1.4.7. Arc protection……
36
5.1.48. Auto-reclose function
37
5.1. 49. Inverse definite minimum time
characteristics
43
REF610
Feeder Protection Relay
1MRs755310
Technical Reference manual
5.1.4.10. Settings………,.57
5.1.4.11. Technical data on protection
nctions
68
5.1.5. Trip-circuit supervision
5.1.6. Trip lockout function
74
5.1.7. Trip counters for circuit-breaker condition
75
5.1.8. Indicator LEDs and operation indication
messages∴∴
.,75
5.1.9. Demand values∴
75
5.1.10. Commissioning tests
76
5.1.11. Disturbance recorder
76
5.1.11.1. Function
76
5.1.11.2. Disturbance recorder data
5.1.113. Control and indication of
disturbance recorder status
78
5.1.11. 4. Triggering
78
5.1.11.5. Settings and unloading
78
5.1.11.6. Event code of the disturbance
recorder
79
5.1.12. Recorded data of the last events
79
5.1.13. Communication ports
81
5.1.14EC 60870-5-103 remote communication
5.1.15. Modbus remote communication protoco
protocol
82
5.1.15.1. Profile of modbus
87
5.1.16. dnP 3.0 remote communication protocol...101
5.1.16.1. Protocol parameters....,.,,... 102
5.1.16.2. dnP 3.0 point list
102
6.1.16.3. DNP 3.0 device profile
..105
5. 1.16.4. Specific DNP features
112
5.1.17. SPa bus communication protocol parameters. 115
5.1.17.1. Event codes
5.1.18. Self-supervision(IRF) system
134
5.1.19. Relay parameterization
136
5.2. Design description
137
5.2. 1. Input/output connections
137
5.2.2. Light sensor input connections
143
5.2.3. Serial communication connections
.143
5.24 Technical data
6. Application examples
155
6.1. Auto-reclose function
155
6.1.1. Fast tripping and initiation of shot 1 using two
protection stages
..155
1MRs755310
Feeder Protection Relay
REF610
Technical Reference Manual
6. 2. Fast tripping and initiation of shot 1 using start
signals
156
6.1.3. Selecting adaptive sequence length
157
6.2. Arc protection
158
6.2.1. Arc protection with one REF610 relay
158
6.2.2. Arc protection with several REF610 relays...159
6.2.3. Arc protection with several REF610 relays and
ne rEa101
160
7. Ordering information.………163
8. Check lists∴
165
9. Abbreviations
171
6
1MRs755310
Feeder Protection Relay
REF610
Technical Reference Manual
Copyrights
The information in this document is subject to change without notice and should not
be construed as a commitment by abb oy abb Oy assumes no responsibility for
any errors that may appear in this document.
In no event shall ABB Oy be liable for direct, indirect, special, incidental or
consequential damages of any nature or kind arising from the use of this document
nor shall ABB Oy be liable for incidental or consequential damages arising from
the use of any software or hardware described in this document
This document and parts thereof must not be reproduced or copied without written
permission from ABB Oy, and the contents thereof must not be imparted to a third
party nor used for any unauthorized purpose
The software or hardware described in this document is furnished under a license
and may be used, copied or disclosed only in accordance with the terms of such
license
C Copyright 2011 ABB Oy
All rights reserved
Trademarks
ABB is a registered trademark of ABB Group. All other brand or product names
mentioned in this document may be trademarks or registered trademarks of their
respective holders
Guarantee
Please inquire about the terms of guarantee from your nearest ABB representative
8
1MRs755310
Feeder Protection Relay
REF610
Technical Reference Manual
Introduction
This manual
This manual provides thorough information on the protection relay rEF610 and its
applications, focusing on giving a technical description of the relay
Refer to the Opcrators manual for instructions on how to usc the human-machine
interface(HMi)of the relay, also known as the man-machine interface(MMI), and
to the Installation manual for installation of the relay
1.2
Use of symbols
This publication includes the following icons that point out safety-related conditions
other
The electrical warning icon indicates the presence of a hazard which
uld result
△
The warning icon indicates the presence of a hazard which could result
The caution icon indicates important information or warning related to
the concept discussed in the text. It might indicate the presence of a
hazard which could result in corruption of software or damage to
equipment or property.
The information icon alerts the reader to relevant facts and conditions
The tip icon indicates advice on, for
le, how to design your
project or how to use a certain function
Although warning hazards are related to personal injury, it should be understood
that operation of damaged equipment could, under certain operational conditions,
sult in degraded process performance leading to personal injury
Therefore, comply fully with all warning and caution notices
Intended audience
This manual is intended for operators and engineers to support normal use of as
well as configuration of the product.
REF610
Feeder Protection Relay
1MRs755310
Technical Reference manual
1.4.
Product documentation
In addition to the relay and this manual, the delivery contains the following relay-
specific documentation
Table 1.4, -1 REF610 product documentation
Name
Document ID
Installation Manual
1MRS752265-MUM
Technical reference manual
1MRS755310
Operators manual
1MRS755311
1.5.
Document conventions
The following conventions are used for the presentation of material
Push button navigation in the human-machine interface(HMI) menu structure is
presented by using the push button icons, for example
To navigate between the options, use4 and
HMI menu paths are presented as follows
Use the arrow buttons to select CONF'IGURAT'ION COMMUNICATION\SEA
SETTINGS\ PASSWCRD SPA
Parameter namcs, menu names, relay indication messages and rclay's HMI vicws
are shown in a Courier font, for example:
Use the arrow buttons to monitor other measured values in the menus DemAND
VALUES and HISTORY DATA
HMI messages are shown inside quotation marks when it is good to point out
them for the user. for example
When you store a new password, the relay confirms the storage by flashing
” once on the display
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.