详细说明:danfoss vlt 2800手册PDF,danfoss vlt 2800手册VLTE 2800 Series
■ Quick Setup
■ General warning
Electrical Installation control cables
Using this Quick Setup, you can carry out quick and Remove the front cover underneath the control
EMC-correct installation of the frequency converte
panel. Place a jumper between terminals 12 and 27
in five steps. The Operating Instructions, which are
also enclosed, give other examples of installation
and describe all functions in detail
②②因
②②
Read the safety instructions
676869
0D2口
△
on the next page before installing the unit.
eaa的
sy∠
L3-
3395
L1 L2 L3
Programming
VLT
Carry out programming on the control panel. Press
50
the QUICK menu key to enter the Quick menu. In
U V PE
e R-R+
this menu, parameters can be selected by means of
88古
the [+ and [-l keys. The parameter values can be
changed by pressing [CHANGE DAIA. Changes are
programmed using the [ and [ keys. Finish the
change of a parameter setting by pressing
3
[CHANGE DATA]. A change of parameter values is
saved automatically atter a mains tailure. It the dis-
lay shows three dots at the right, the parameter
value has more than three digits. In order to see the
Mechanical Installation
value, activate [CHANGE DATA. Press [ QUICK
VLT 2800 frequency converters allow side-by-side in
MENU: Set the motor parameters that are on the
stallation. Because of the need for cooling there
plate of the motor
must be 10 cm free air passage above and below
Motor power ( kW
parameter 102
the frequency converter. Drill holes in accordance
Motor voltage M
parameter 103
with the measurements given in section Mechanical
Motor frequency [Hz]
parameter 104
dimensions. Retighten all four screws
Motor current [A
parameter 105
Fit the decoupling plate to the pawer cables and the
Rated motor speed
parameter 106
earth screw(terminal 95)
Activate AMt
Automatic motor tuning parameter 107
Electrical Installation, power
Please note that the power terminals can be re
moved. Connect mains to the mains terminals of the
Set reference range
frequency converter, i. e. 91, 92, 93 and the earth
Min. reference, Refmin
parameter 204
connection to terminal 95. Fit a screened/armoured
cable from the motor to the motor terminals of the
Max reference, RefmAX
parameter 205
frequency converter, i.e. U, V,W. The screen ends in
a screen connector
Ramp-up time
parameter 207
me [s parameter 208
MG.28. A6. 02-VLT is a registered Danfoss trade mark
VLTE 2800 Series
In parameter 002 Local/remote control, the fre
4. The earth leakage current is higher than 3.5 mA
quency converter mode can be selected as Remote
5. Protection against motor overload is not included
operation o, i.e. via the control terminals, or Local
in the factory setting. If this function is required
L1, i.e. via the control unit
set parameter 128 Motor thermal protection to
data value ETR Trip or ETR Warning
Set the control location to Local [1]
6. Check that the mains supply has been discon-
ocal/remote operation = Local [1] Par. 002
nected before removing the motor and mains
plugs
Set the motor speed by adjusting the local refer
ence
Warning against unintended start
Local reference Parameter 003
△
I he motor can be brought to a stor
by means of digital commands, bus com-
mands. reterences or local stop, while the
■ Motor start
frequency converter is connected to mains. If per-
Press [Start to start the motor. Set the motor speed sonal safety considerations make it necessary to
by adjusting parameter 003 Local reference
ensure that no unintended start occurs, these stops
Check whether the direction of rotation of the motor
are not sufficient. While parameters are being pro-
grammed, the motor may start. Consequently the
shaft is clockwise. If not, exchange any two phases
on the motor cable. Press stoP /ReSet to stop
stop key STOP/RESE TI must always be activated,
following which data can be modified. A motor that
the motor. Press QUlCK menu to return to display
mode
has been stopped may start if faults occur in the
QUICK MENU+ [+ keys must be pressed simulta
electronics of the frequency converter, or if a tempo-
rary overload, a fault in the supply mains or a fault in
neously to give access to all parameters
the motor connection ceases
■ Safety regulations
The voltage of the frequency converter
△
can be fatal whenever it is connected to
mains. Incorrect installation of the motor
or the frequency converter may lead to damag
the equipment, serious personal injury or death.
Consequently, the provisions of this Quick Setup, as
well as national and local rules and safety regula
tions, must be complied with
Touching the electrical parts may be fatal, even after
the equipment has been disconnected
wait at least 4 min
1. I he mains supply to the frequency converter must
be disconnected if repair work is to be carried out
2. The [SIOP/RESE key on the control panel of
the frequency converter does not disconnect the
mains supply and is
i thu
not to be used as a
safety switch
3. Correct protective earthing of the unit must be es
tablished, the user must be protected against
supply voltage, and the motor must be protected
against overload in accordance with applicable
national and local regulat
1G. 28.A6.02-VLT is a registered danfoss trade mark
VLTE 2800 Series
vLT2803-2815200240V
VLT2840200240V
vLT2805-2815380-480V
vLT2855-2875380480V
OCV
vLT2822200-240V
vLT2822-2840380-480V
vLT28802882380480V
MG.28. A6. 02-VLT is a registered Danfoss trade mark
VLTE 2800 Series
■ Software version
VLT 2800 Series
Operating instructions
Software version:2.5x
c∈
These operating instructions can be used for all VLT 2800
Series frequency converters with software version 2. 5x
The software version number can be seen from parameter
640 Software version no
NBI
IK Indicates something to be noted by the reader
△
Indicates a general warning.
△
ndicates a high-voltage warnin
6
MG.28.A6.02-VLT is a registered danfoss trade mark
VLTE 2800 Series
■ General warning
For the north american market The etr func
tions provide overload protection of the motor
The voltage of the frequency converter is
class 20. in accordance with nec
△
dangerous whenever the converter is con
6. Do not remove the plugs for the motor-and
nected to mains. Incorrect fitting of the
mains supply while the frequency converter is
motor or frequency converter may cause damage to
connected to mains. Check that the mains supply
the equipment, serious injury or death. Conse-
has been disconnected
that the prescrib
quently, it is essential to comply with the instructions
time has passed betore removing motor and
in this manual as well as local and national rules and
mains plugs.
safety regulations
7. Note that the frequency converter has more volt-
ge inputs than L1, L2 and L3 when the dC bus
terminals are used. Check that all voltage inputs
These rules concern your safety
are disconnected and that the prescribed time
1. The frequency converter must be disconnected
has passed before repair work is commenced
from the mains if repair work is to be carried out
Check that the mains supply has been discon
nected and that the prescribed time has passed Warning against unintended start
before removing motor and mains plugs
1. The motor can be brought to a stop by means of
2. The [stoP/ReSet key on the control panel of
digital commands, bus commands, reterences or
the frequency converter does not disconnect the
a local stop, while the frequency converter is con
equipment from mains and is thus not to be used
nected to mains. It personal satety considerations
as a safety switch
make it necessary to ensure that no unintended
The unit must he properly connected to the earth,
start occurs, these stop functions are not sutti
the user must be protected against the supply
voltage and the motor must be protected against 2. While parameters are being changed, the motor
overloading pursuant to prevailing national and lo-
may start. Consequently the stop key stoP/Re
cal regulations.
SET must always be activated, following which
4. The earth leakage currents are higher than 3.5
data can be modified
mA
3. A motor that has been stopped may start if faults
5. Protection against motor overload is not included
occur in the electronics of the trequency con
in the factory setting. If this function is required
verter, or if a temporary overload or a fault in the
set parameter 128 Motor thermal protection to
supply mains or the motor connection ceases
data value ETR trip or data value ETR warning
△ Warning:
t can be extremely dangerous to touch the electrical parts
even when the mains supply has been disconnected
Also ensure that other voltage inputs are disconnected
from load sharing for example(sharing of dc intermediate
CIrcul
For voi 2800: wait at least 4 minutes
195NA139.10
MG.28. A6. 02-VLT is a registered Danfoss trade mark
VLTE 2800 Series
■ Control unit
[+]/[- are used for selecting parameters and for
On the front of the frequency converter there is a
changing parameter values
control panel
These keys are also used in Display mode for se
lecting the display of an operating value
The [qUICK MENU]+[+] keys must be pressed at
LEBEI
the same time to give access to all parameters. See
Menu mode
[STOP/RESET] is used for stopping the connected
motor or for resetting the frequency converter after a
tri
QUICK
ClIANGE
MENU
CATA
Can be selected as Active [1 or Not active o via
parameter 014 Local stop/reset. In Display mode,
the display will flash if the stop function is activated
3OALARM WARN NG O ON
nB!
I if the I STOP/RESET key is set at Not ac-
SIOP
tive [o in parameter 014 Local stop/reset, and
SIAR
there is no stop command via the digital inputs or
式-S上
serial communication, the motor can only be
g the mains voltage to the
frequency conver te
[START] is used for starting the
The control panel is divided into four function groups: It is always active, but the [start key cannot over
1. Six-digit LED display
ride a stop command
2. Keys for changing parameters and shifting display
function
3. Indicator lamps
Manual initialisation
4. Keys for local operation
Disconnect mains voltage. Hold the QUICK menu
All displays of data are in the form of a six-digit LED
[+]+[CHANGE DaTA keys down while simultane
display capable of showing one item of operating
ously reconnecting the mains voltage. Release the
data continuously during normal operation. As a
keys; the frequency converter has now been pro
supplement to the display, there are three indicator
grammed for the factory setting
lamps for indication of mains connection(on), warn
ing(WARNING)and alarm(ALARM). Most of the
trequency converter's parameter Setups can be
changed immediately via the control panel, unless
this function has been programmed as Locked [
via parameter 018 Lock for data changes
■ Control keys
[QUICK MENU] allows access to the parameters
used for the quicκmenu
The[QUiCK menu key is also used if a change to a
parameter value is not to be implemented
ee also [QUICK MENU++]
[CHANGE DATA] is used for changing a setting
The [CHange DatA key is also used for confirming
a change of parameter settings
8
1G. 28.A6.02-VLT is a registered danfoss trade mark
VLTE 2800 Series
Display readout states
If for a given parameter the display shows three dots
Display mode
at the right, it means that the parameter value has
more than three digits. In order to see the value, ac-
tivate CHANGE DAIA
n normal operation, one item of operating data can
be displayed continuously at the operators own
choice. By means of the [+/- keys the following op
12日
tions can be selected in Display mode
Output frequency [Hz]
Output current A
Output voltage M
The display shows that in parameter 128 Motor ther
Intermediate circuit voltage
mal protection the selection made is Thermistor trip
Output power kW
Scaled output frequency fout x p008
Quick met
Menu mode
QUICK
+
MENU
Using the [qUICK MenU key, it is possible to
access the 12 most important parameters of the fre
quency converter. After programming, the frequency
converter is in most cases ready for operation
n order to enter the Menu mode QUlCK menu+
When the QUlCK menu key is activated in display
[+ must be activated at the same time
mode, the Quick menu starts. Scroll through the
n Menu mode, most of the frequency converter
quick menu using the [+/ keys and change the data
parameters can be changed. Scroll through the pa
values by first pressing [CHANGE DaTA and then
rameters using the [+/- keys. While scrolling in the
changing the parameter value with the +/-keys
Menu mode proceeds, the parameter number will
TheQuick menu parameters are
Par. 102 Motor power PM,, N
Par. 103 Motor voltage UMN
Par. 104 Motor frequency
MN
Par. 105 Motor current /MN
LILIL
Par. 106 Rated motor speed nM.N
Par. 107 Automatic motor adaption
Par. 204 Minimum reference Refmin
Par. 205 Maximum reference RefmAX
Par. 207 Ramp-up time
The display shows that the setting in parameter 102
Par. 208 Ramo-down time
Motor power PM.N is 0. 75. In order to change the
Par. 002 Local/remote operation
value of 0.75, CHANGE DATA] must first be acti
Par. 003 Local reference
vated; the parameter value can then be changed
Ising the [+/-] keys
Parameter 102-106 can be read out from the mo
tor's nameplate
Hand aut
During normal operation the frequency converter is
Auto mode, where the reference signal is given
lly analog or digital via the control terminals
However, in Hand mode it is possible to give the ref
e signal locally via the control panel
MG.28. A6. 02-VLT is a registered Danfoss trade mark
VLTE 2800 Series
On the control terminals, the following control signals
Automatic motor tuning
will remain active when Hand mode is activated
Automatic motor tuning (AMT) is performed as tol
Hand Start(LCP2)
Off Stop(LCP2)
Auto Start(LCP2
1. In parameter 107 Automatic motor tuning select
Reset
data value[2].“107" Will now flash,and“2”wil
Coasting Stop Inverse
not flash
Reset and Coasting Stop Inverse
2. AMT is activated by pressing start. 107 will now
Quick Stop Inverse
lash and dashes will move from left to right in the
· Stop Inverse
data value field
Reversing
3.When“107” appears once more with the data
DC Braking Inverse
value o, AMT is complete. Press [STOP/RE-
Setup Select LSB
SET to save the motor data
· Setup Select MSB
4.“107” will then continue to flash with the data
Thermistor
value O. You can now proceed
Pre
Precise Stop/Start
og
Stop Command Via Serial Comm
Switching between Auto-and Hand mode:
sy activating the [Change Data key in isplay
Model, the display will indicate the mode of the fre-
quency converter
DATA
Scroll up/down in order to switch to hand mode
When the frequency converter is in Hand mode the
readout will be like
and the reference can be changed by using the fol
lowing keys
nBI
K Please note, that
parameter 020 may block the choice of mode
10
1G. 28.A6.02-VLT is a registered danfoss trade mark