文件名称:
Telemecanique Premium Atrium Profibus-DP用户手册(英文).pdf
开发工具:
文件大小: 1mb
下载次数: 0
上传时间: 2019-10-11
详细说明:Telemecanique Premium Atrium Profibus-DP用户手册(英文)pdf,Telemecanique Premium Atrium Profibus-DP用户手册(英文)Table of contents
Safety Information
7
About the book
9
Part general introduction to communication
on profibus dP
11
At a glance
Chapter 1 Introduction to Profibus DP
n∴,,,13
At a glance
General introduction to Profibus DP
14
General architecture and protocol for profibus dP
Multi-master architecture
Features of profibus dP
18
Part Installation of
At a glanc
Chapter 2 Performance
n,,,.21
At a glance
Data transfer
22
Network cycle
Application response time
Chapter 3 Description of the TsX PBY 100 module
,,.27
At a Gla
3.1 Description of module
28
At a glance
28
General description
Operating mode
Connecting the Profibus DP b
3.2 Installing the module
3
Mounting the module in a rack
3.3 Technical specifications
At a glance
37
Compatibility
Standards and characteristics
Operating conditions
Part l Software installation of the profibus dp bus
43
At a Glance
Chapter4 General.∴
■■■
At a glance
Principle
Physical or logical addressing of inputs/outputs
48
Mapping IW and QW addresses
Chapter 5 TSX PBY 100 module configuration.......... 51
At a glance
51
Declaring the TSX PBY 100 module and accessing application screens
52
Configuration screen for a Profibus DP link
Data to be provided
Resulting data from the decoding of the"CNF text file
Viewing Profibus dP master configuration
General module configuration
Module configuration file
61
Chapter 6 Programming profibus dP communication ..............63
At a glar
63
Profibus dP diagnostIcs
Diagnostics command
Examples of diagnostics command
Communication/operation report
Chapter 7 Debugging the TSX PBY 100 module.
■■
At a glance
Description of the debug screen
Debugging parameters
Chapter 8 TSX PBY 100 module diagnostics
At a glance
Diagnostics of the module's status from the LEDs
78
Degraded project modes
79
Lists of diagnostics variables
81
List of available diagnostics
83
Compact diagnostics of all slaves
Slave diagnostics
85
General information on a slave
86
Slave configuration data
....87
Chapter 9 Profibus DP communication language objects...... 91
At a glar
9. 1 Language objects and IODDTs for Profibus dP communication using the
TSX PBY 100 module
92
At a glance
2
Presentation of the language objects for Profibus DP communication
93
Implicit exchange language objects associated with the application-specific
function
Explicit exchange language objects associated with the application-specific
function
95
Management of Exchanges and Reports with Explicit Objects
9. 2 General language objects and IODDTs for all communication protocols
At a glance
10
Details of ioddt implicit exchange objects of type T CoM stS Gen
102
Details of IODDT explicit exchange objects of type T_COM_STS_GEN
103
9. 3 ODDTs for profibus dp communication
105
At a glance
105
Details of the implicit exchange objects of the T_COM_PBY-type IODDT.... 106
Details of the implicit exchange language objects for a Profibus dP function.. 111
Language objects associated with configuration
112
Error codes for module tsX Pby 100
9. 4 The lOddT type T_GEN_ MOD applicable to all modules
115
Details of the Language Objects of the IODDT of Type T GEN MOD
115
Index
n,.117
6
Safety Information
Important Information
NOTICE
Read these instructions carefully, and look at the equipment to become familiar with
the device before trying to install, operate, or maintain it. The following special
messages may appear throughout this documentation or on the equipment to warn
of potential hazards or to call attention to information that clarifies or simplifies a
procedure
The addition of this symbol to a Danger or Warning safety label indicates
A
that an electrical hazard exists, which will result in personal injury if the
instructions are not followed
△
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death
A DANGER
DANGER indicates an imminently hazardous situation, which, if not avoided, will
result in death, serious injury, or equipment damage
△ WARNING
WARNING indicates a potentially hazardous situation, which, if not avoided, can result
in death serious injury or equipment damage
A CAUTION
CAUTION indicates a potentially hazardous situation, which, if not avoided, can result
in injury or equipment damage
Safety Information
PLEASE NOTE All pertinent state, regional, and local safety regulations must be observed when
installing and using this product. For reasons of safety and to ensure compliance
with documented system data, only the manufacturer should perform repairs to
components.
When controllers are used for applications with technical safety requirements,
please follow the relevant instructions
No responsibility is assumed by Schneider Electric for any consequences arising out
of the use of this material. this document is not intended as an instruction manual
for untrained persons
o Schneider electric 2003
All rights reserved
About the book
At a glance
Document Scope This manual describes the implementation of hardware and software of the
TSX PBY 100 module for profibus dp communication with Premium and atrium
PLCS
Validity Note
The data and illustrations found in this documentation are not binding. We reserve
the right to modify our products in line with our policy of continuous product
development
The information in this document is subject to change without notice and should not
be construed as a commitment by schneider electric
Product Related Schneider Electric assumes no responsibility for any errors that may appear in this
Warnings
document. If you have any suggestions for improvements or amendments or have
found errors in this publication, please notify us
No part of this document may be reproduced in any form or by any means, electronic
or mechanical, including photocopying, without express written permission of
Schneider electric
All pertinent state, regional, and local safety regulations must be observed when
installing and using this product
For reasons of safety and to ensure compliance with documented system data, only
the manufacturer should perform repairs to components
When controllers are used for applications with technical safety requirements,
please follow the relevant instructions
Failure to observe this product related warning can result in injury or equipment
damage
User Comments We welcome your comments about this document. You can reach us by e-mail at
techpubschneider-electric.com
About the book
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.