文件名称:
Telemecanique System Planning and Installation Guide.pdf
开发工具:
文件大小: 3mb
下载次数: 0
上传时间: 2019-10-09
详细说明:Telemecanique System Planning and Installation Guidepdf,Telemecanique System Planning and Installation GuideTable of contents
Safety Information
5
About the book
7
Chapter 1 Site Requirements for an Advantys sTB island Installation.9
At a gla
Advantys Stb Islands of Automation
.10
Inside the Enclosure
Power Supply selection
14
Extending the island
17
Operating Environment
23
Chapter 2 Advantys sTB System Installation Procedures.,..,..27
At a gla
27
The Layout of Modules on an Island Bus
.,,.,28
The din rail
3
Installing the nim in the First Location on the island
36
Keying considerations
42
Interlocking base Units on the din rail
Installing the Last device on the Primary Segment.
55
Installing Advantys STB Modules in their Bases
Chapter 3 EXtending an Advantys STB Island Bus
63
Overview
.63
Island bus extensions
Installing Extension Segments of Advantys STB Island Modules...... 67
Installing a preferred module extension
68
Chapter 4 Safety and grounding considerations.......... 69
Overview
Power Isolation Requirements on the island bus
70
Safety Switchin
The Protective Earth Connection
,72
The functional earth connection
73
EMC Kits
.74
890USE171C0 September 2003
Chapter 5 Commissioning an Advantys sTB Island
81
Overview
81
Making Fieldbus and Power Connections
82
Configuring the island
85
Hot Swapping Advantys STB Modules
....88
Fault Detection and Troubleshooting......
Glossary
101
Index
117
890USE17100 September 2003
Safety Information
Important Information
NOTICE
Read these instructions carefully, and look at the equipment to become familiar with
the device before trying to install, operate, or maintain it. The following specia
messages may appear throughout this documentation or on the equipment to warn
of potential hazards or to call attention to information that clarifies or simplifies a
procedure
A
The addition of this symbol to a danger or Warning safety label indicates
that an electrical hazard exists which will result in personal injury if the
instructions are not followed
△
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. obey all safety messages that follow this symbol to avoid
possible injury or death
∧ DANGER
DANGER indicates an imminently hazardous situation, which, if not avoided, will
result in death, serious injury, or equipment damage
△WARN|NG
WARNING indicates a potentially hazardous situation, which, if not avoided,can result
in death, serious injury, or equipment damage
A CAUTION
CAUTION indicates a potentially hazardous situation, which, if not avoided, can result
in injury or equipment damage
890USE17100 September 2003
Safety Information
PLEASE NOTE Electrical equipment should be serviced only by qualified personnel. No responsi-
bility is assumed by schneider Electric for any consequences arising out of the use
of this material this document is not intended as an instruction manual for untrained
persons
C 2003 Schneider electric
All Rights reserved
890USE17100 September 2003
About the book
At a glance
Document Scope This book describes concepts for planning and procedures for installing an Advantys
network interface module, one or more power distribution modules, various WO
STB island. The installation will comprise some combination of an Advantys S
modules, and perhaps some island bus extension modules and cables
Validity Note
The data and illustrations found in this book are not binding. We reserve the right to
modify our products in line with our policy of continuous product development. The
information in this document is subject to change without notice and should not be
construed as a commitment by schneider Electric
Related
Documents
Title of documentation
Reference Number
The Advantys STB Hardware Components Reference Guide
89oUsE17200
The Advantys sTB Profibus dP Network Interface Applications Guide 890USE17300
The Advantys STB INTERBUS Network Interface Applications Guide 890USE17400
The Advantys STB Device Net Network Interface Applications Guide 890USE17500
The Advantys STB CANopen Network Interface Applications Guide 890USE17600
The Advantys STB Ethernet Modbus TCP/P Network Interface
890UsE17700
Applications Guid
The Advantys STB Modbus Plus Network Interface Applications
890UsE17800
The Advantys STB Fipio Network Interface Applications Guide
890USE17900
The Advantys Contiguration Software Quick Start User Guide
890USE18000
890USE17100 September 2003
About the book
Product Related Schneider Electric assumes no responsibility for any errors that may appear in this
Warnings
document. If you have any suggestions for improvements or amendments or have
found errors in this publication, please notify us
No part of this document may be reproduced in any form or by any means, electronic
or mechanical, including photocopying, without express written permission of
Schneider Electric
All pertinent state, regional, and local safety regulations must be observed when
installing and using this product. For reasons of safety and to assure compliance
with documented system data, only the manufacturer should perform repairs to
components
User Comments We welcome your comments about this document. You can reach us by e-mail at
TECHCOMM modicon com
8
890USE17100 September 2003
Site Requirements for an
Advantys STB Island Installation
At a glance
Overview
This chapter describes the external requirements that need to be considered when
you select and plan your Advantys STB installation
What's in this This chapter contains the following topics
Chapter?
Topic
Page
Advantys STB Islands of Automation
side the enclosure
13
Power Supply Selection
14
Extending the Island
17
Operating Environment
890USE17100 September 2003
Site Requirements
Advantys sTB Islands of Automation
System
Advantys STB is an open, modular distributed w/o system designed for the machine
Definition
industry, with a migration path to the process industry. Modular I/O and power
distribution devices reside on the island bus. the island functions as a node on a
fieldbus control network and communicates with the fieldbus master controller
Open Fieldbus An island can function as a node on the following open industry-standard fieldbus
Choices
networks
Profibus dp
DeviceNet
Ethernet
CANopen
Wipo
Modbus plus
INTERBUS
A network interface module(NIM) resides in the first position of the island bus
(leftmost on the physical setup). the Nim acts as the gateway between the island
and the fieldbus, facilitating data exchange between the fieldbus master and the l/o
modules on the island. It is the only module on the island that is fieldbus-
dependent-a different type of NiM module is available for each fieldbus. The rest
of the l/o and power distribution modules(PDMs) on the island bus function exactly
the same, regardless of the fieldbus on which the island resides. you have the
advantage of being able to select l/O modules and establish island functionality
independent of the fieldbus on which it will operate
V0 Modules on In your application, you can combine a comprehensive set of lo modules
the island
specifically designed for the island with island-compliant devices from other
Schneider product catalogs(called preferred modules). Standard CANopen devices
can also be included in your combination of l/o devices
Granularity
Advantys STB l 0 modules are designed to be small, economical devices that
provide you with just enough input and output channels to satisfy your application
needs. Specific types of l/O modules are available with two or more channels. You
can select exactly the amount of lo you need and you do not have to pay for
channels that you dont need
10
890USE17100 September 2003
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.