详细说明:施耐德变频器ATV21 Lonworks card用户手册(英文)pdf,施耐德变频器ATV21 Lonworks card用户手册(英文)Contents
Important Information
Before you begin
Introduction
Documentation structure
Hardware setup
Receipt
56789999
Hardware description
Use of RS485 communication port
Description of terminals
10
stalling the card in the drive
Connecting to the bus
Topology
12
Cable routing practices
13
Wiring the LONWORKS connector
Configuration
Drive parameters overriden by the LONWORKs network
Configuration of the internal communication
Configuration of the control
15
Control by the LoNWoRKs network
15
Control by terminals, monitoring by the LON WORKs network
16
Control by the LONWORKs network, switching setpoint to terminals by logic input
Setpoint by the LoNWoRks network, switching commands to terminals by logic input
Configuration of the lonworks fault
18
Diagnostics
20
Service LED
20
Troubleshooting
20
Functional profile
21
Objects supported
21
LONMARK Node Object profile
LON MARK Variable Speed Motor Drive profile
22
Network variables and configuration properties
23
List of network variables and configuration properties
Commands and setpoints
25
Drive Speed Setpoint (nviDrv SpeedStpt)
25
Drive Speed Setpoint Scaling(nviDrvSpeedScale
25
Default Value for nviDrvSpeedScale(nciDrvSpeedScale)
25
Frequency setpoint (nvilnvSetFreq
Reset command(nviResetFault
6
Status and output velocity
28
Drive Speed Feedback(nvoDrv Speed)
28
Drive Velocity feedback(nvoDrv Feedback
28
Output frequency(nvolnvOutFreq)
28
Drive status(nyoStatusWord)
9
Alarms
3
Alarm code(nvoDrv Alarm)
31
Alarm status(nvoAlarmWord)
31
Measurements
32
Drive Output Current (nvoDrvCurnt)
Drive Total Running Hours(nvoDrvRunHours)
Energy consumption(nvoDrvEnergy
Torque actual value(nvo Torque)
32
Monitoring of digital input
33
Monitoring of digital input F(nvoDigitalln1)
33
Monitoring of digital input R(nvo Digitalln2)
Monitoring of analog inputs
Monitoring of analog input viB(nvoAnalogIn2
Control of digital outputs
33
Control of relay FL (nviRelay 1)
33
Emergency
Emergency command(nviEmergoverride)
Emergency status(nvoEmerg Status)
34
176959210/2009
Contents
Adjustment
Maximum Motor Speed(nciMaxSpeed)
35
Minimum Motor Speed (nciMin Speed)
35
Nominal Motor Speed in RPM(nciNmISpeed)
36
Nominal Motor Frequency(nciNmlFreg
36
Minimum Ramp Up Time(nciRampUpTm)
Minimum Ramp Down Time(nciRampDownTm)
37
Parameter access
38
nviParamCmd, nvoParamResp
Identification
Location Label (nciLocation)
dentification(nvo Type Ver)
Network management
41
Send Heartbeat Time(nciSndHrtBt)
41
Receive Heartbeat Time(nciRcvHrtBt
41
Minimum Send Time(nciMinOutTm)
Power supply start waiting time(ncipwUpOutTm
While every precaution has been taken in the preparation of this document, Schneider
Electric SA assumes no liability for any omissions or errors it may contain, nor for any
damages resulting from the application or use of the information herein
The products described in this document may be changed or modified at any time,
either from a technical point of view or in the way they are operated. Their description
can in no way be considered contractual
176959210/2009
1. Important Information
NOTICE
Read these instructions carefully, and loak at the equipment to become familiar with the device before trying to install, operate, or maintain
it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call
attention to information that clarifies or simplifies a procedure
A
The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists, which will result in
personnal if the instruction are not followed
A
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. obey all safety messages that follow
this symbol to avoid possible injury or death
A DANGER
DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death, serious injury, or
equipment damage
A WARNING
Warninig indicates a potentially hazardous situation, which, if not avoided, can result in death, serious injury, or
equipment damage
A CAUTION
CAUTION indicates a potentially hazardous situation, which, if not avoided, can result in injury or equipment
damage
PLEASE NOTE
Electrical equipment should be serviced only by qualified personnel. No responsibility is assumed by Schneider Electric for any
consequences arising out of the use of this material. This document is not intended as an instruction manual for untrained persons
o 2005 Schneider Electric. All Rights Reserved
176959210/2009
2. Before you begin
Read and understand these instructions before performing any procedure with this drive, in order to completely and correctly
utilize excellent performance of this unit
Besides this user manual, you will find in the chapter"Documentation structure"which manuals we advice you to read to develop software
communicating with Altivar 21
If you need support, please contact our sales offices
After reading this instruction manual, please keep it handy for future reference
Read and understand these instructions before performing any procedure with this drive
A DANGER
HAZARDOUS VOLTAGE
Read and understand the Installation Manual before installing or operating the Altivar 21 drive Installation, adjustment, repair, and
maintenance must be performed by qualified personnel
The user is responsible for compliance with all international and national electrical standards in force concerning protective grounding
of all equipment
Many parts of this variable speed drive, including the printed circuit cards, operate at the line voltage. DO NOT TOUCH.
Use only electrically insulated tools
DO NOT touch unshielded components or terminal strip screw connections with voltage present
DO NOT short across terminals Pa and PC or across the dc bus capacitors
Install and close all the covers before applyit
lower or starting and stopping the drive
Before servicing the variable speed drive
Disconnect all power
Place a"DO NOT TURN ON"label on the variable speed drive disconnect
Lock the disconnect in the open position.
Disconnect all power including external control power that may be present before servicing the drive. WAIT 15 MINUTES to allow the
DC bus capacitors to discharge. Then follow the dc bus voltage measurement procedure given in the Installation Manual to verify that
the DC voltage is less than 45 VDC. The drive LEDs are not accurate indicators of the absence of dc bus voltage
Electric shock will result in death or serious injury
A CAUTION
DAMAGED EQUIPMENT
Do not install or operate any drive that appears damaged
Failure to follow this instruction can result in injury or equipment damage
176959210/2009
3. Introduction
Thank you for purchasing the LONWORKs option card (VW3A21312)for Altivar 21 drive
By installing this card into the Altivar 21, data communication can be made with a host computer or other device via LoNWoRks network
The communication card has an open-style 3-pin connector for connection to the network. It supports free topology at 78 kbit/s
Data exchanges give access to all Altivar 21 functions
Control(start, sto
Monitoring(status, current, voltage, thermal state.),
Diagnostics(alarms
The LonWoRks resource files( XIF.)that provide the network configuration tools(Lon Maker. with device information are available on
theweBsitewww.schneider-electric.comandonthecdromdeliveredwitheachdrive
The plug-in software tool that provides easy access to setting-up, testing and monitoring the ATV21 drive is also available on the Web site
www.schneider-electric.comandonthecdromdeliveredwitheachdrive
LONWORKS, LONMARK, Lon Maker, Neuron are trademarks of Echelon Corporation registered in the United States and other countries
LONMARK and LoN MARK Logo are managed, granted, and used by LoNMARK International under a license granted by Echelon Corporation
176959210/2009
4 Documentation structure
■ LONWORKS ATV21 manua
The present LONWORKS user manual describes
connection to Lon Works network
configuration of the communication-specific parameters via the HMI
diagnostics
networks variables
You will also find important information in other Altivar 21 technical documents. They are available on the Web site
www.schneider-electric.comandonthecdromdeliveredwitheachdrive
ATV21 user manual
This manual describes:
How to assemble the drive
How to connect the drive
The functions and the parameters of the drive
How to use the drive hmi
If you use the Parameter access function of (nviParamCmd, nvoParamResp), will find in this manual the address and possible values of
the parameters of the drive
■ Modbus atv21 manual
This manual describes
Connection to the bus or network
Configuration of the cammunication-specific parameters
Diagnostics
Software setup,
Modbus services supported
If you use the Parameter access function of (nviParamCmd, nvoParamResp), will find in this manual the address and possible values of
additional parameters not described in aTV21 user manual
176959210/2009
5. Hardware setup
5. 1. Receipt
Check that the card reference printed on the label is the same as that on the delivery note corresponding to the purchase order
Remove the option card from its packaging and check that it has not been damaged in transit
The LONWORKs card is shipped together with the following accessories. On opening the packing case, check to see if the following
accessories are contained or not
1 cabling label and 2 name plates (1 sheet
1 insulating sheet
3 neuron ID labels( barcode EAN128
5.2. Hardware description
Service pin
SW2
Selector switch SW1
Connector to drive
Logic for f, r terminal
(SINK/SOURCE)
VIB function
(VIB/PTC)
Service LED
n
FR∨|BCCP24
Terminal board
fixing screw hole
(M3 screv
NETA SHLDNETB
G/E FLA FLB Flc
RS485 communication port
RJ45
Earth connection terminal
LONWORKs network detachable terminal
A DANGER
Operate service pin only when a cover for the main circuit terminal is attached. Otherwise, it could lead to electric
shocks
Operate service pin using a non-conductive stick When it is operated with a conductive stick, it could lead to
electric shock
5. 3. Use of RS485 communication port
Serial communication(2-wire RS485 option can be used for Modbus, PC software or remote keypad
One internal communication line is available either for the RS485 communication port or for the LoNWoRks port
So, while RS485 communication is used(connected to the appropriate cable or interface) the lonWorks port is disabled
176959210/2009
5. Hardware setup
5. 4. Description of terminals
Terminal Function
Electrical specifications
nternal circuits
symbol
NETA
No polarity
NETA
NETB
LONWORKs transmission data /reception data
NETB(
This terminal is not connected to any
SHLD LONWORKS communication shield terminal
other circuit of the card ground this
SHLD
terminal in a location separated from
FT-×1
ne ground of power line
G
Spark
G/E Grounding terminal
Please connect to network ground
gap
Multifunctional programmable logic input
P24
has forward rotation function in default setting
ON forward rotation drive
No voltage contact input
F24
SOURCE
OFF: slowdown and stop
24VDC. 5mA or less
Multifunctional programmable contact input
SINK/SOURCE can be selected with
SW1
It has reverse rotation function in default setting
本水
FR
ON: reverse rotation drive
OFF: slowdown and stop
Multifunction programmable analog input
(0 to 60Hz frequency with 0 to 10VDC input. ng. 10VDC
Vib It has speed set point function in the default setti
PTC/ VIB
In addition, this terminal can be used as PTC input by Internal impedance: 30kohm
setting the parameters( F645 and F646)and sw1
Cc Control circuit equipotential terminal
P2424 VDC power supply output
24VDC-50mA
P24「
Multifunctional programmable relay contact outputs. 30VDC-05A
FLa Default setting is set to detect the activation of the
250VAC-1A
-B inverter protection function
日
FLC Contact across FLA-FLC is closed and FLB-FLC is 250VAC-05A
opened during protection function operation
(cosφ=04)
LC
A DANGER
Do not change switch settings while power is on
It may damage the product or lead to electric shocks and breakdown
When setting the VIB function, set the parameter after configuring removed motor cables. The motor may suddenly
start and that could result in injury
176959210/2009