详细说明:萨姆森SAMSON 3730系列3730-3型电气定位器,带HART通信功能安装操作手册(英文版)pdf,萨姆森SAMSON 3730系列3730-3型电气定位器,带HART通信功能安装操作手册(英文版)Contents
Contents
Page
Important safety instructions
9
Article code
Design and principle of operation
3.1
Application type
12
3.2
Additional equipment
13
3.3
Communication
14
3.3
Configuration using tr○ VIS-VIEW so「ware
14
3.4
Technical data
15
4
Attachment to the control valve- Mounting parts and accessories
18
4.1
Direct attachment
20
Type 3277-5 Actuator
20
4.1.2
Type 3277 Actuator
4.2
Attachment according to lEC 60534-6 (NAMUR)
24
Attachment to Type 3510 Micro-flow Valve
26
Atte
nt to rotary actuators
28
4.5
Reversing amplifier for double-acting actuators
30
4.5
Pressure gauge attachment
30
Attaching an external position sensor
32
4.6
Mounting the position sensor with direct attachment
32
4.6.2
Mounting the position sensor with attachment according to IEC 60534-6 34
4.6.3
Mounting the position sensor to type 3510 Micro-flow Valve
35
4.6.4
mounting the position sensor to rotary actuators
36
Attaching positioners with stainless steel housings
.37
4.8
Air purging function for single-acting actuators
37
4.9
Required mounting parts and accessories
38
5
Connections
42
5.1
Pneumatic connections
42
5.1
Signal pressure gauges
42
5.1.2
Supply pressure
42
5.1.3
Signal pressure(output)
43
5.2
Electrical connections
43
5.2.
Switching amplifiers
45
5.2.2
Establishing communication
46
666
Operator controls and readings
48
Serial inter
50
HART③ communication
50
Contents
Start-up- Settings
7.1
Determining the fail-safe position
51
7.2
Setting the volume restriction Q
52
7.3
Adapting the display
52
7.4
Limiting the signal pressure
53
7.5
Checking the
operating range of the positioner
53
7.6
Initialization
54
7.6.1
MAX- Initialization based on maximum range
56
7.6.2
NOM- Initialization based on nominal range
57
7.6.3
MAN-Initialization based on a manually selected range
58
7.6.4
SUb substitute calibration
59
7.7
zero calibration
62
7.8
Performing settings for open/ close valves
63
7.9
Reset to default values
65
8
Operation
66
8.1
Enabling and selecting parameters
66
8.2
Operating modes
8.2.1
Automatic and manual modes
67
8.2.2
Fail-safe position (SAFE)
8.3
Malfunction/maintenance alarm
68
8.3.1
Confirming error messages
69
Adjusting the limit switch
70
Retrofitting an inductive limit switch
10
Maintenance
73
Servicing explosion-protected devices
73
Code list
74
Settings in TROVIS-VIEW software
13
general
99
13.1
System requirements
99
13.2
Installing trovis-view software
100
13.3
Starting TROVIS-VIEW and performing basic settings
101
13.4
Data transmission
..103
13.4
Offline operation(indirect data transmission
104
13.4.2
Online operation(direct data transmission)
104
13.4.3
Setting parameters
105
13.5
Initializing the positioner
107
13.6
Status classification
109
4EB8384-3EN
Contents
14
Dimensions in mm
.111
15
Valve characteristic selection
112
Test certificates
114
EB83843EN5
Modifications of positioner firmware
cifications of positioner firmware in comparison to previous versions
Pre
ecIous
Ney
1.00
1.10
The HART protocol as per HART specification Revision 5 is supported by default set
g
The setting can be changed to HART Revision 6 over TROVIS-VIEW HART tools as
well as AMs or handheld communicators are currently not supported by the Revision 6
version
The following additional status messages were implemented
Code 76- No emergency mode
Code 77- Program loading error
Displays number of zero calibrations performed since the last initialization
For initialization of "AIR TO CLOSE" actuators, the direction of action( Code 7)is auto
matically set to increasing/decreasing
Code 3, the activation period of the enabled configuration function was
extended to 120 s
1.10
1.20
Electronics changed no new functions added
1.20
130
New EXPERT diagnostics functions(Code 48)added
Positioner in EXPERT+ version with extended diagnostics features
A running initialization can be canceled by pressing the rotary pushbutton
The position transmitter Code 37 )and solenoid valve Code 45 )options are automati
cally recognized
130
1.40
All EXPERT+ FUnctions can be used over hart communication in this firmware version
and higher.
The fault alarm contact is triggered by the condensed state of the positioner. It is al-
ways active when condensed state="Maintenance alarm
If Code 32 is set to yes also active with"Function check "condensed state
If Code 33 is set to Yes: Also active with"Maintenance required/ Maintenance de
anded"condensed state
The"Function check"condensed state is additionally set for Test Al, A2, fault alarm
output and position transmitter
The min. /max. values of the temperature monitoring can be reset
6EB83843EN
Modifications of positioner firmware
Modifications of positioner firmware in comparison to previous versions
Previous
New
1.40
1.41
Internal modifications
1.41
1.42
Internal modifications
1.42
1.51
Setting can be performed at the positioner to determine whether the valve is to operate
as a control valve or an on/off (open/close)valve(see section 3. 1)
All EXPERT diagnostic functions are available in the positioner without having to
activate them first(refer to EB 8389 EN on EXPERT valve diagnostics
Optional binary input with following actions(refer to EB 8389 EN on EXPERT valve
Set local operation write protection
Start Partial Stroke Test(PST)
Go to fail-safe reference variable
Switch between AUTO/MAN
Start data logger
Reset diagnosis
External solenoid valve connected
Leakage sensor
The pressure limit( Code 16) is no longer automatically set during initialization
1.51
1.52
Internal modifications
EB8384-3EN7
8EB83843EN
Important safety instructions
Important safety instructions
For your own safety follow these instructions concerning the mounting start-up and opera
tion of the positioner
The positioner may only be mounted started up or operated by trained and
experienced personnel familiar with the product
According to these Mounting and Operating Instructions, trained personnel refers to
individuals who are able to judge the work they are assigned to and recognize
possible dangers due to their specialized training, their knowledge and experience as
well as their knowledge of the relevant standards
Explosion-protected versions of this positioner may only be operated by personnel
who have undergone special training or instructions or who are authorized to work
on explosion-protected devices in hazardous areas. Refer to section 11
Any hazards that could be caused by the process medium, the operating pressure
the signal pressure or by moving parts of the control valve are to be prevented by
means of the appropriate measures
If inadmissible motions or forces are produced in the actuator as a result of the supply
pressure, the supply pressure must be restricted by means of a suitable supply
pressure reducing station
To avoid damage to any equipment, the following also applies
Do not operate the positioner with the back of the positioner/vent opening facing
The vent opening must not be sealed when the positioner is installed on site
Vent
Proper shipping and appropriate storage are assumed
Note: The device with a CE marking fulfills the requirements of the Directives 94/9/EC
(ATEX and 89/336/EEC (EMC)
The declaration of Conformity is available on request
Article code
2 Article code
Article code
TyPe3730-3×x×xx0××0×00×0×x
With LC display, autotune, HART communication
Explosion protection
Withou
0
‖2 G EEx ia‖CT6/2DP65T80°acc. to ateX
CSA/ FM intrinsically safe/non incendive
‖3 G EEx na ll t6川3DP65T80°Cac. o ATEX
8
Options(additional equipment
Inductive limit switch
Without
With Type Sj 2-SN
Solenoid valve SIL 4
Without
24V DC
4
Analog position transmitter
Without
With
External position sensor
Without
0
With
Binary input
With
0
2
Diagnostics
EXPERT plus
Housing material
Aluminum
0
Stainless steel 1. 4581
Special applications
None
0
Free of paint-impairing substances
Exhaust air connection with 1/4 NPT thread
2
Special versions
00
IECEx
10EB8384-3EN