您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 天水二一三DZX2_4-100L系列剩余电流动作断路器样本下载.pdf
  所属分类: 其它
  开发工具:
  文件大小: 2mb
  下载次数: 0
  上传时间: 2019-10-08
  提 供 者: weixin_********
 详细说明:天水二一三DZX2_4-100L系列剩余电流动作断路器样本下载pdf,DZX2/4-100L系列剩余电流动作断路器 国■国国■国国■国国国国国国国国 >>正常工作条件与安装条件 WORKING CONDITION AND INSTALLATION CONDITION △最高空气温度为+40℃C,最低空气温度为-5C,24h内的平均值不超过+35C Environment temperature: -5C -+40C, the average hours oftemperature exceeding +35C during 24 hours △安装地点的海拔高度不超过2000m。 Elevation:≤2000m △环境应为不会引起爆炸的介质,也无会腐蚀金属或破坏绝缘的有害气体和导电尘埃。 Environment condition: There must be not any explosive medium and there must be not any gas which would corrode metal or any conducting dust which would destroy the insulation △安装在无明显冲击和振动的地方 Products should be used in no significant impact and vibration place △安装类别Ⅱ Installing categories: ClassⅡ △污染等级为2。 Pollution protection: Grade2 △安装方式为I35-75标准卡轨安装。 Mounted by Th35-7.5 standard rail track △采用带夹头的接线端子。 Chuck connection with the use of the terminal >>主要技术参数 MAIN TECHNICAL PARAMETERS 额定剩余电流 额定剩余电流 产品型号 分断能力 极数 接线能力 T Breaking 动作电流mA)不动电流(mA) 分断时间t Pole Rated leakage capacity agenor Breaking time wiring operating current operating current capacity 30 15 DZX2/4-100L IP、2P 10KA 100 t≤0.ls 35 mm 3P,4P 300 150 >>接线图及外形尺寸 WIRING PICTURE AND OUTLINE DIMENSIONS 接线示意图 型式 注意事项 外形尺小(mm) Wiring picturc Type Notice Outline dimensions 单极两线 1相、零线不可接错 Phase, the zero-line access cannot be wrong 81×140x77 One pole two2适用丁415V及以下的电路中。 lines Adapt in 415v and below circuit 两极两线 适用于415V及以下的电路中。 Two poles two Adapt in 415V and below circuit 108×140×77 lines 8 DZX2/4-100L系列剩余电流动作断路器 1源端必须接零线,且剩余电流动作断路器不 能断开零线 三极四线 Supply-side must take a zero linc, and residual 三b温 current devices can not be disconnected zero line Three poles2.相、零线不可接错 170×140×77 hase, the zero-line access can not be wrong 3适用」415V及以下的电路中 Adapt in 415v and below circuit 四极四线 相、零线不可接错 Four pules2适用于415V及以下的电路中 197x140×77 four lines Adapt in 415V and below circuit >>使用说明 OPERATING INSTRUCTION △剩余电流动作断路器的额定剩余动作电流、过载及短路特性均在出厂前整定合格,使用中不得随意调节 Leakage circuit breakers rated action leakage current, overload and short-circuit manufacturing by setting characteristics, can not be used in regulation. △剩余电流动作断路器在安装运行一段时间后(一般为每隔个月),需要在合闸通电状态下,按动试验按 钮,剩余电流动作断路器应可靠动作。 In the new circuit breakers installed to run after a certain period of time(generally every month), the need to switch on power in the state, rather than pressing the test button, and leakage circuit breakers should be relia ble action Δ当剩余电流动作断路器因漏电保护而动作后,漏电指示按钮弹起。剩余电流动作断路器再次合闸之前,应 先按下漏电指示按钮。 As a result of leakage circuit breakers and protection of the action, the leakage direction button up. Circuit breaker switch on again until the leakage should be directed to press the button △剩余电流动作断路因被保护电路发生故障而分闸后,需查明原因,排除故障后方可合闸 Protection of the circuit breaker was malfunctioning gate hours, the reasons for the need to identify before troubleshooting closing. △剩余电流动作断路器对同时接触被保护电路的两根导线引起的触电危险,不能进行保护 Leakage circuit breakers on the circuit at the same time to protect access to the two wires caused by the danger of electric shock and can not protect △相、零线不可接反。 Phasc, the zero line should not take anti Δ在裝设剩余电流动作断路器的配电系统中,剩余电流动作断路器负载侧的零线既不允许重复接地,也不允 许互相连接或就近支接。 Leakage circuit breakers in each branch line to be protected hy its own dedicated line of zero and zero end load line is not allowed to connect with each other and will not allow access to the nearest branch >>订货须知 ORDER NOTICE ■用户订货时,需指明剩氽电流动作断路器的名称、型号规格及数量。 如:剩余电流动作断路器DZX2-100L100A/3P300mA50台。 Users need attention the entitle type, the value ofrated residual working current and volume of breaker Example: DZX2-100L 100A/3P 300mA breaker 50sets 79
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: