您好,欢迎光临本网站![请登录][注册会员]  
文件名称: CT变频器unidrive使用说明书.pdf
  所属分类: 其它
  开发工具:
  文件大小: 2mb
  下载次数: 0
  上传时间: 2019-09-20
  提 供 者: weixin_********
 详细说明:CT变频器unidrive使用说明书pdf,CT变频器unidrive使用说明书Chapter Logic sense Logic levels 3-2 Signal modes of analog frequency reference input T 3-2 Making the signal connections 3-4 Descriptions of the default control signal connections Regeneration Terminal and keypad modes 1-2 Controlling the speed of the motor 1-3 Serial communications Using VtcSoft 1-4 Parameters and menus 2-2 Arrangement of the menu o parameters 2-2 Using macros 2-3 Configur ing and controlling the Drive 2-3 Conventions 2-3 ypes of parameter 2-3 Making new values effective and saving them 2-3 Where to find information on parameters 2-4 Making temporary connections Operating instructions for terminal mode 2-6 Operat ing instructions for Keypad mode 2-7 Appendix Saving the default values A-7 VTC LV Model size Model code Nominal rating for standard The Unidrive VTC (variable Torque Control)is Ac motors designed to control ac induction motors when used HP specifically in pump and fan applications. The range UNI 1201VTC 0.37 0.5 of models covers an output range from 0.75kWto 110kW for standard Drives (415 Vac) and 0. 37kw te UNI 1202VTC 0.55 0.75 22 kW for low voltage drives(220vac)-nominal UNI 1203VTC 0.75 values. Each model has an overload capacity of up UNI 1204 VTC 1.5 to 120%of its rated output current for 60 seconds. UNI 1205VTC 2.2 3.0 UNI 220IVTC 3.0 4.0 UNI 2202VTC 4.0 5.0 UNI 2203VTC 5.5 7.5 This User guide refers to the models listed below UNI 3201VTC 7.5 UNI 3202VTC Model size Model code Nominal UNI 3203VTC 20 rating for standard Ac UNI 3204VTC 30 kW HP UNI 1401VTC075 UNI 1402 VTC1. 15 UNI 1403VTC15 2.0 This User Guide is arranged on a step-by-step basis UN|1404VTC2.2 3.0 to lead you through the following UNI 1405 VTC4.0 50 Learning how to operate the drive UNI2401VTC5.5 7.5 Setting up the Drive for basic applications UN2402VTC|7.5 Accompanying this guide is the Unidrive VTC UNI 2403 VTC110 nsta∥ ation guide. UN3401VTc15020 UN|3402VTc18.525 UN|3403VTC22030 A Variable speed drives may be hazardous if misused carefull read this User guide and ∪N|3404VTC300 Warning Chapter 2 Safety Informatlon in UN3405VTC|37.050 the Installation Guide UN|4401VTC45060 UN|4402VTC55075 UN|4403VTC750 100 UN4404VTC|90.125 UN|4405VTC1100125 The voltage/frequency characteristic of a variable If required, the drive can be configured for the speed drive affects the load/frequency use of macros. These require only a small number of designed to be compatible with the quadratic ' characteristic of the motor the Unidrive vtc following means of controlling motor speed by the software par ameters to be adjusted in order to load/frequency characteristic of fans and pumps perform the configuration: This saves substantial energy compared with direct on-line(DOL)star ting of motors Macro Function number At low frequencies, variable voltage boost allows the starting torque to be increased above the values Easy mode for analog frequency control for that follow the normal square-law basic applications( the user is initially aware of only a limited number of parameters) The voltage and torque characteristics are shown in Motorized potentiometer (frequency Appendix D controlled by up and down contacts) our preset frequencies that are selected by external digital control signals PID(set-point) control The Unidrive VTC can be used with a standard Unidrive operating in the Regeneration mode. The It is not essential that a macro is used but for ease Unidrive Vtc itself cannot operate in the of getting started, Chapter 2 is based on using the Regeneration mode Drive in macro 1 easy mode The main features of the other macros are listed in Appendix b macros A Before a Drive is used in the Regeneration mode, the drive and the accompanying Warning motoring Drive(s), including VTC models, must be modified Contact the supplier of the Drive for details If this is your first encounter with a Unidrive VTC you may wish to try it out before installing it. From this you can learn how to set up and control it. Ir this case, refer to Safety Information in the installation Guide, then Product familiarization using the Drive in easy mode(Macro 1)in Chapter 2 Getting Started The Drive is supplied in either of two default configurations to suit the continent in which it is sold. The configurations are distinguished as follows EUR> European voltage, 50Hz AC Supply The motor can be started and stopped, the USA> USA Voltage, 60HZ AC supply direction of rotation reversed and the speed changed by operation of the Drive in either of the When not specified, the related information applies following modes to both configurations Terminal mode Applying signals from electrical contact system controller or PLc to digital and analog Operation of the drive can be extended by the use inputs on the drive of plug-in option modules. The following modules Keypad mode are available from the supplier of the Drive; an appropriate User Guide is included with each panel of the Drive. Only essential signalont lal operation of the keypad on the fre module connections are made to the drive Small option modules UDSO Additional i/o UDS5 Cloning(parameter copying) The motor speed can be controlled in either of the Large option modules following two ways: UD70 Intelligent applications Frequency control UD71 RS232/RS485 serial communications The output frequency of the drive is controlled by a UD73 Profibus dp interface frequency reference. This reference can be in any of the following forms: UD74 Inter bus s interface UD75 CTNET interface An analog signal that is applied to the Drive (Terminal mode) UD76 ModBus plus interface User-specified preset frequency references (two available in the default mode, eight available by changing the configuration of the Drive) that can be selected by contacts onnected to digital inputs on the Drive By the user pressing keys on the front panel of the Drive(Keypad mode PID control The drive can be configured by the use of macro 5 to operate with a frequency reference and an analog feedback device for dynamically controlling the speed under PId control (Terminal mode). The Drive can be configured and fully controlled from a system controller or PLc operating on a RS232 or a 4-wire rS485 serial communications link a Basic serial communications large option module or an appropriate Second processor large option module must be fitted in the drive. more information can be obtained from a drive centre or distributor listed at the end of this user guide Serial communications can be used in conjunction with Terminal mode or Keypad mode The Unidrive vtc can be configured and controlled from a Pc by use of the VtcSoft program which is supplied on diskette and operat es under Microsoft Windows M(version 3. 1 and later A Basic serial communications large option module or an appropriate Second processor large option module must be fitted in the drive, a serial communications interface must be fitted in the pc for any of the following modes RS232 Four-Wire$485 Two-wire rs485
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: