详细说明:CT变频器unidrive使用说明书pdf,CT变频器unidrive使用说明书Chapter
Logic sense
Logic levels
3-2
Signal modes of analog
frequency reference input T
3-2
Making the signal connections
3-4
Descriptions of the default
control signal connections
Regeneration
Terminal and keypad modes
1-2
Controlling the speed of the motor
1-3
Serial communications
Using VtcSoft
1-4
Parameters and menus
2-2
Arrangement of the menu o parameters 2-2
Using macros
2-3
Configur ing and controlling the Drive 2-3
Conventions
2-3
ypes of parameter
2-3
Making new values effective
and saving them
2-3
Where to find information
on parameters
2-4
Making temporary connections
Operating instructions
for terminal mode
2-6
Operat ing instructions
for Keypad mode
2-7
Appendix
Saving the default values
A-7
VTC LV
Model size
Model code
Nominal rating
for standard
The Unidrive VTC (variable Torque Control)is
Ac motors
designed to control ac induction motors when used
HP
specifically in pump and fan applications. The range
UNI 1201VTC
0.37
0.5
of models covers an output range from 0.75kWto
110kW for standard Drives (415 Vac) and 0. 37kw te
UNI 1202VTC
0.55
0.75
22 kW for low voltage drives(220vac)-nominal
UNI 1203VTC
0.75
values. Each model has an overload capacity of up
UNI 1204 VTC
1.5
to 120%of its rated output current for 60 seconds.
UNI 1205VTC
2.2
3.0
UNI 220IVTC
3.0
4.0
UNI 2202VTC
4.0
5.0
UNI 2203VTC
5.5
7.5
This User guide refers to the models listed below
UNI 3201VTC
7.5
UNI 3202VTC
Model size
Model code
Nominal
UNI 3203VTC
20
rating for
standard Ac
UNI 3204VTC
30
kW
HP
UNI 1401VTC075
UNI 1402 VTC1.
15
UNI 1403VTC15
2.0
This User Guide is arranged on a step-by-step basis
UN|1404VTC2.2
3.0
to lead you through the following
UNI 1405 VTC4.0
50
Learning how to operate the drive
UNI2401VTC5.5
7.5
Setting up the Drive for basic applications
UN2402VTC|7.5
Accompanying this guide is the Unidrive VTC
UNI 2403 VTC110
nsta∥ ation guide.
UN3401VTc15020
UN|3402VTc18.525
UN|3403VTC22030
A
Variable speed drives may be
hazardous if misused carefull
read this User guide and
∪N|3404VTC300
Warning Chapter 2 Safety Informatlon in
UN3405VTC|37.050
the Installation Guide
UN|4401VTC45060
UN|4402VTC55075
UN|4403VTC750
100
UN4404VTC|90.125
UN|4405VTC1100125
The voltage/frequency characteristic of a variable
If required, the drive can be configured for the
speed drive affects the load/frequency
use of macros. These require only a small number of designed to be compatible with the quadratic '
characteristic of the motor the Unidrive vtc
following means of controlling motor speed by the
software par ameters to be adjusted in order to
load/frequency characteristic of fans and pumps
perform the configuration:
This saves substantial energy compared with direct
on-line(DOL)star ting of motors
Macro
Function
number
At low frequencies, variable voltage boost allows
the starting torque to be increased above the values
Easy mode for analog frequency control for
that follow the normal square-law
basic applications( the user is initially aware
of only a limited number of parameters)
The voltage and torque characteristics are shown in
Motorized potentiometer (frequency
Appendix D
controlled by up and down contacts)
our preset frequencies that are selected by
external digital control signals
PID(set-point) control
The Unidrive VTC can be used with a standard
Unidrive operating in the Regeneration mode. The
It is not essential that a macro is used but for ease Unidrive Vtc itself cannot operate in the
of getting started, Chapter 2 is based on using the Regeneration mode
Drive in macro 1 easy mode
The main features of the other macros are listed in
Appendix b macros
A
Before a Drive is used in the
Regeneration mode, the drive
and the accompanying
Warning motoring Drive(s), including
VTC models, must be modified
Contact the supplier of the
Drive for details
If this is your first encounter with a Unidrive VTC
you may wish to try it out before installing it. From
this you can learn how to set up and control it. Ir
this case, refer to Safety Information in the installation
Guide, then Product familiarization using the Drive in
easy mode(Macro 1)in Chapter 2 Getting Started
The Drive is supplied in either of two default
configurations to suit the continent in which it is
sold. The configurations are distinguished as
follows
EUR> European voltage, 50Hz AC Supply
The motor can be started and stopped, the
USA> USA Voltage, 60HZ AC supply
direction of rotation reversed and the speed
changed by operation of the Drive in either of the
When not specified, the related information applies following modes
to both configurations
Terminal mode
Applying signals from electrical contact
system controller or PLc to digital and analog
Operation of the drive can be extended by the use
inputs on the drive
of plug-in option modules. The following modules
Keypad mode
are available from the supplier of the Drive; an
appropriate User Guide is included with each
panel of the Drive. Only essential signalont
lal operation of the keypad on the fre
module
connections are made to the drive
Small option modules
UDSO
Additional i/o
UDS5
Cloning(parameter copying)
The motor speed can be controlled in either of the
Large option modules
following two ways:
UD70
Intelligent applications
Frequency control
UD71
RS232/RS485 serial
communications
The output frequency of the drive is controlled by a
UD73
Profibus dp interface
frequency reference. This reference can be in any of
the following forms:
UD74
Inter bus s interface
UD75
CTNET interface
An analog signal that is applied to the Drive
(Terminal mode)
UD76
ModBus plus interface
User-specified preset frequency references
(two available in the default mode, eight
available by changing the configuration of
the Drive) that can be selected by contacts
onnected to digital inputs on the Drive
By the user pressing keys on the front panel
of the Drive(Keypad mode
PID control
The drive can be configured by the use of macro 5
to operate with a frequency reference and an analog
feedback device for dynamically controlling the
speed under PId control (Terminal mode).
The Drive can be configured and fully controlled
from a system controller or PLc operating on a
RS232 or a 4-wire rS485 serial communications link
a Basic serial communications large option module or
an appropriate Second processor large option module
must be fitted in the drive. more information can
be obtained from a drive centre or distributor
listed at the end of this user guide
Serial communications can be used in conjunction
with Terminal mode or Keypad mode
The Unidrive vtc can be configured and controlled
from a Pc by use of the VtcSoft program which is
supplied on diskette and operat es under Microsoft
Windows M(version 3. 1 and later
A Basic serial communications large option module or
an appropriate Second processor large option module
must be fitted in the drive, a serial
communications interface must be fitted in the pc
for any of the following modes
RS232
Four-Wire$485
Two-wire rs485
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.