1.3 Operating Settings
Port 1 Setting format
aNPort web Console -Microsoft Internet Explorer provided by Honeywell, Inc.
File Edt View Favorites Tools Heb
0ck·+④的奋设5 rch FAvorites8hd·当h以x
Addresslahttp!/192.168.1,100f
o GoLinks
www.oxa.co
-Opcrating Settings
口 Basic settings
Port=01
口 Network settings
Operation mode
TCP Server Mode
-a Serial Settings
TCp alive check time
in)
Port
Port 2
Inactivity time
(-65535ms
口Pot3
Max connection
1-4)
画port4
Data Packing
Port 5
O Port 6
Del miter 1
(Hex)厂 Enable
Port 7
Del miter 2
(Hex)厂 Enable
a Operating Settings
Force transmit
(0-65535ms)
口Pot1
TCp S
hcal TCP port
口Pat3
口pnrt5
Apply the above settings to all serial ports (Local listen port will be enumerated automatically)
Submil
ge Pass
o Ioad Cstr resil
D Internet
画的Now.她c,象到多BM国m,小圆回」的里12065
Port 2 Setting format
a NPort web Console-Microsoft Internet [xplorer provided by Honeywell, Inc.
|×
File Edt view Favorites Tools Heb
中Bk·→,④团5Fa每M出·当回hQ
Address Http:!/192161.100
z PGo Links >
wwW.oxa, co
Main Menu
OPerating Settings
Basic Setting
Purt -02
□ Network Settings
Operation mode
TCP Server Mode-
国 Serial Settings
TCP alive check time
a Purt 1
(o-9g min)
□pat2
Inactivity time
0-65535ms)
□pnrt3
Max connection
(1-4)
a Port 4
Data Packing
OrT
a port 6
(Hex)「 Enable
u Port
Del miter 2
p(+ex)厂 Enable
t Operating Settings
Force transmit
(0-65535ms)
noz
a port 3
口Pot
Command port
□pot5
Apply the abcve settings to all serial ports (Local listen port will be enumerated automatically
白Pot7
Sub
Port 8
O Auto Warning Settings
Passwor
f Iosd Eactory default
Lane
Internet
典叫!画钟Mtw.cmg,虹,多B,国man,田kn圖圆pr」蹲的通号1205
Honeywell
Port 8 Setting format
NPort Web Console-Microsoft Internet Explorer provided by Honey well, Inc.
File Edt view Favorites Tools Hep
中Bak,+,③团企 I Favorites Me的③团目品Qg
Addressehttp:/192.168.1.100f
pG0tnks”
MO
www.moxa.com
± Operating Settings
口 Overview
□ Basic settings
Port=08
口 Network Settings
Operation mode
TCP Server Mode
Et Serial Settings
TCp alive check time
(0-99mn)
a Port 1
口pot2
Inactivity time
0-65535ms
口Pot3
Max connection
(1-4)
Port 4
Data Packing
a Port 5
口pot6
Del miter 1
(-ex)厂 Enable
Del miter 2
p (Hex)C Enable
口Port
-t Operating Settin
Force transmit
卩(-6530
a Port 1
TCP Server Mode
a Port 2
Local TCp port
口pot3
d port
口Pot4
a Port 5
Apply the above settings to all serial ports(Local listen port will be enumerated automatically)
a Port 7
Submit
口pot8
口 Accessible IP Settings
+□ Auto Warning Settings
a Change password
m Inad Factory nofault
圈
Dane
4 Internet
奥画的时,她h鲁,多址国mm图hea,画W,國pmen」国b造骂124
Honeywell
2. Quick Builder
2.1 Builder channels
To define a channele
Click -to display the Add items dialog
Select Channel as the item and Modbus as the type
3. Set the property values on the main tab
F记 e Edit View Tous
D回某曲“可|日日「
Channels
CHAMOD1
CHNDT
Channels
A] CHAMOD2
CHND2
知 CHAMOD3
MainPort Redundant PortI
Name CHAMOD1
F。 oil Ala m Limit
Recycle Din
Diagnostic S
2
ten t
Last Modified 2005-0-5 12
Item Number CHNI
ast Downloaded 2005-9-5 12- 02- 55
叫画白‖Mm,她c配,鲁,降多e…m黑M,侧,回pwm,,」瞬国的嫗单1241
Click the port tab and for port Type
Serial
Terminalserver
LANVendor
See Modbus channel port properties.
Terminalserver port properties
roperty
Description
Terminal Server TCP Host The name and port number of the terminal server to which the
Name
channel is connected
Honeywell
Terminal Server TCP Port You can specify either a TCP host name or an IP address, but it must
NO
match the tCP host name used when you installed and internally
configured the terminal server
Idle Timeout
The time in seconds the channel waits for a successful connection to
the server before closing the connection
a value of o indicates that the connection is never closed
Checksum
Set this to none
Protocol
Modbus protocol to use when communicating with devices on this
channel. the default is modbus rtu
Select one of the following
Modbus rtu
Modbus ascii
To define a redundant channela
Click the redundant port tab
2. Select Redundantserial or LANVendor as the port Type
set the other properties as appropriate- see Modbus channel redundant port properties
The Redundant Port settings must be the same as the port settings, except for the port name
Fle Edit view Tools Help
Channels
Channel
A CHAMOD2
CHND2
A CHIAMO
CHND3
uritrvleIs
Main Port Redundant Pot
Port Type Ter
Protocol Modbus RTU
station?
121E1U
TCP Host Name
Idle Timeout BU
Checksum NONE
圃叫山画‖,她c,鲁m,降k國…M,」国,國,國m,b溜鸚s12
Honeywell
2.2 Builder controlle
Defining a Modbus controller
In the current context, a"controller is a logical controller that corresponds to a data table within a
trolle
You need to define a" controller for each Modbus data table(see Click here) in the physical
controller that you need to access. (Unless you have combined data within tables see reducing
the number of data tables being scanned.
To define a controller
1. Click -to display the Add Items dialog
2
Select Controller as the item and modbus as the type
Set the property values on the Main tab. See Modbus controller main properties.
B quick Builder-\\YKL-ESA\QDB$\QBDatabaseadb
Fie Edit view Tools Help
易自鹛的x日日
Controllers
ItemName
Controller char
翻 CONMOD1
RTUDD1
Chanrels-CONMOD2
RTUDD2
CHAMOD2
- CONMOD
RTUDJ3
CONMOD4
CH△MDD3
M
Name CONMCD1
Channel Name CHAMDD1
Servers
Fal Alarm Limit 50
Protocol Modbus RTU
PLC Staion ID
Data T able Holding Register
Diagostic Address
Last Modified 2005-9-5 12- 02-55
Item Number RTUOOT
Laat downcaded 20059-5 12- 02-55
卖3④画即N,她c,鲁m降B,国m,田h圆w,」國im,厘1m,国b单舄12l
Honeywell
2. 3 Builder points
區影串鹛
=x日日|厂
Point
目
ItemName
Item Description ArsaCodsSouceAcdess.
Test
CONMOD1 002
Channels.2
CONMOD2 003
Teste
CONMOD4 003
PoinTs
R Address Builder
c
Main Display Alarms Control Audary History I Scripts User Defined I
ddress Type Controler
Point ID best1
Stations
Description
Cancel
Controle
0D1
PV Souice Address[CONM001 002u16b
Location 002 u16b
Fv Scan Period 2
Help
E
Er
Units
100% Value65535
Recycle Bin
Drift Deadband(&) 0.000
Action Alao NONe
v Scannng Enabled Clamp P
em Ts
Last Modified 2005-9-5 12- 02- 55
Last downloaded 2005-9-512- 02-55
演叫画n,cm参m,限B国mk,田m,圆w,mmm国乳忌z6
Data format for scaling 16-bit integers
You can scale point parameter values with a data format if they have addresses in the input
Register and Holding register data tables. Select the format that corresponds to the counts that
have been set in the controller register
Data Format Counts in Controller Register
U4095(default)o to 4095
U9999
o to 9999
U999
0 to 999
U15B
0to32767
U16B
0to65535
S16B
-32768to32767