详细说明:台达可编程控制器(PLC)DVP06XA-E2安装说明pdf,台达可编程控制器(PLC)DVP06XA-E2安装说明:本安装说明书提供给使用者电气规格、功能规格、安装配线的相关注意事项。其它详细之程序设计及指令说明请见DVP-ES2 操作手册【模块篇】,选购的周边装置详细说明请见该产品随机安装说明书。· Input
X03÷
Shielded cab|e·1
CH4
FE
power module
DC/DC
Converter #AG
-15V
Grounding (100g or less)
Figure 3]
· Output
AC motor drive
--、CH5
CH5
scale valy
Shielded cable*4
AC motor drive
scale valve
Shielded cable*4
DC/DC
+15V
DC24V
Class 3 grounding(100n or less)
Figure 4]
*1: When performing analog input, please isolate other power wirings
#2: When the XA module is connected to current signals, make sure you short-circuit"V+""and"I+
#3: If the ripples at the loaded input terminal are too significant that causes noise interference on the
ing to 0.7
#4: When performing analog output, please isolate other power wirings
#5: If the ripples at the loaded output terminal are too significant that causes noise interference on the
wiring, connect the wiring to 0. 1-0.47uF 25V capacitor
*6: Please connect the terminal on both the power module and XA module to the system earth point
and ground the system contact or connect it to the cover of power distribution cabinet
lo Terminal Layout
V1+1+V1V2+|12+V2V3+3+3-V4+14+V4
D∨P06XAE2(4A2AO)
24VTOVTO FEFE FE VO1 IO1 102AG
Electrical Specifications
DVPO6XA-E2
Power supply voltage 24VDC (20.4VDC-28.8VDC)(-15%-+20%)
Max rated power
2.5W, supplied by external power source
Connector
European standard removable terminal block(Pin pitch: 5mm)
2
DVPO6XA-E2
Operation/storage
Operation: 0oC-55C(temp. ) 50-95%(humidity), Pollution degree2
Storage:-25°c-70°c(temp.),5-95%( humidi
bration/shock
International standards: IEC61131-2, IEC 68-2-6(TEST FC)
mmunity
Ec61131-2&EC68-2-27( TEST Ea)
Series connection to
The modules are numbered from 0 to 7 automatically by their
DVP-PLC MPU
distance from mPu. max. 8 modules are allowed to connect to mPu
and will not occupy any digital l/O points
Functions Specifications
Common specifications
Digital data format
2s complement of 16 bits
Response time
Overall accuracy
0.5% when in full scale within the range of (25 C,77"F)
±1% when in full scale within the range of(0-55°C,32~131°F)
Optical coupler isolation between digital circuits and analog circuits
No isolation among analog channels
500VDC between digital circuits and Ground. 500VDC between
analog circuits and Ground. 500VDC between analog circuits and
digital circuits. 500VDC between 24VDC and Ground
Analog/ Digital
Current input
Analog input channel 4 channels/each module
Range of analog input +10V
±5V
±20mA
0~20mA
4~20mA
Range of digital
±32,000±32,000±320000-32,0000~32000
Max / Min. output ra9|±32384|±32384|±32,384-384-+32384|-384-+32384
Hardware Resolution 14 bits 14 bits 14 bits 13 bits
3 bits
≥1MQ
Range of absolute input+15V
±32mA
Function
Supported. Available for setting up sampling range in CR#8
CR#11. Range: K1-K100
Self-diagnosis
Upper and lower bound detection in all channels
Digital Analo
Voltage output
Current output
Analog output channel 2 channels/each module
Range of analog output[-10V-10V
4mA-20mA
Range of digital
-32,000~+32,000
0~+32,000
0~+32000
Max/Min input range of -32,768-+32,767
0~+32,767
-6.400~+32.767
digital data
Hardware Resolution 14 bits
4 bits
14 bits
lax. output current
Tolerance load
1KQ-2MQ
0~5009
Output impedance 0.52 or lower
Voltage output is protected by short circuit. Short circuit lasting for
too long may cause damage on internal circuits. Current output can
3
a Control Register
CR#Attrib
Register name
oR Model name
Set up by
DVP06XA-E2 model code = H00C4
Display th
Input mode: Default = H0000 Take CH1 for
#2 R/ CH1 Input mode setting
example
#3o R/ CH2 Input mode setting
Mode 1(H0001 ): Voltage input (+5V)
Mode 2(H0002 ): Voltage input (0++10v)
#4 o R/ CH3 Input mode setting
Mode 4(H0004): Current input (+20mA)
Mode 5 (H0005): Current input(0++20mA)
#5 R/ CH4 Input mode setting
Mode 6 (H0006): Current input(4-+20mA)
Mode-1(H'FFFF): Channel 1 unavailable
Output mode: Default H0000 Take CH5
O R/ CH5 output mode setting
or example
Mode O(H0000): Voltage output (+10V)
(H0001)
#7 R/ CH6 output mode setting
Mode 2(H0002): Current output (4-+20mA)
Mode-1(H'FFFF): Channel 5
#8 O/CH1 sampling range
#9 ORW CH2 sampling range
Set sampling range in CH1 - CH4
#10 R/ CH3 sampling range
Range =K1-K100
Default =K10
#11 O R/ CH4 sampling range
#12 XR CH1 average input value
#13XR CH2 average input value
Average value of in
als at CH1
#14xR CH3 average input value
#15XR CH4 average input value
#16 X R/W CH5 output signal value
Voltage output range: K-32,000-K32, 000
Current output range: KO-K32,000
#17X/ CH6 output signal value
Default: Ko
R CH1 present input value
R CH2 present input value
R CH3 present input value
Present value of input signals at CH1-CH4
#23xI R CH4 present input value
#28 oR/ Adjusted Offset value of CH1
29o R/ Adjusted Offset value of CH2 Set the adjusted Offset value of CH1-CH6
#30 o R/ Adjusted Offset value of CH3
Default KO
Definition of offset in dvpo6XA-E2.
#31 o R/ Adjusted Offset value of CH4 The corresponding voltage (current)input
#32 o R/ Adjusted Offset value of CH5 value when the digital output value =0
#33 R/ Adjusted Offset value of CH6
#34 o R/ Adjusted Gain value of CH1
JO RW Adjusted Gain value of CH2 Set the adjusted Gain value in CH1-CH6
#36 o R/ Adjusted Gain value of CH3 Default=K16,000.Definition of Gain in
DVP06XA-E2: The corresponding voltage
#37 o R/ Adjusted Gain value of CH4
(current)input value when the digital output
#38o R/ Adjusted Gain value of CH5 value=16,000
#39 o R/ Adjusted Gain value of CH6
0o R/ Set value changing prohibited
Prohibit set value changing in CH1 - CH4
Default= H0000
#41/ Save all the set values
ave all the set values Default =H0000
4
CR# Attrib. Register name
#42 X R/W Return to default setting
Set all values to default setting default
#43
R Error status
storing all error status. Refer to
table of error status for more information
#100o R/ Enable/ Disable limit detection Enable/Disable the upper and lower bound
#101X R/ Upper and lower bound status
Display the upper and lower bound value,
Default =H0000
#102o R/ Set value of CH1 upper bound
#103o R/ Set value of CH2 upper bound
#104o R/ Set value of CH3 upper bound Set value of CH1-CH6 upper bound
#105 R/ Set value of CH4 upper bound Default =K32000
#106o R/ Set value of CH5 upper bound
#107 o R/ Set value of CH6 upper bound
#108o R/ Set value of CH1 lower bound
#109o R/ Set value of CH2 lower bound
#110 RW Set value of CH3 lower bound Set value of CH1-CH6 lower bound
#111o RW Set value of CH4 lower bound Default =K-32000
#112o R Set value of CH5 lower bound
#113o R/ Set value of CH6 lower bound
#114 RM Output update time of CH5
Set output update time of CH5 - CH6
#115o R/ Output update time of CH6
LV output mode setting of Ch5
Set the output mode of CH5-CH6 when the
#1180RW|-Ch6
power is at LV(low voltage) condition
Default=o
Symbols: O: When CR#41 is set to H5678, the set value of CR will be saved
X: set value will not be saved
R: able to read data by using FROM instruction
W: able to write data by using TO instruction
Explanation on Special Registers D9900-D9999
When DVP-ES2 MPU is connected with modules, registers D9900-D9999 will be
reserved for storing values from modules. You can apply MoV instruction to operate
values in D9900-D9999
When DVP-ES2 MPU is connected with DVP06XA-E2, the configuration of special
registers is as below:
Module Module Module Module Module Module Module Module
#0
#2
#3
#5
Description
D1320D1321D1322D132301324D1325D1326D1327 Model code
D9900D9910D9920D9930D9940D9950D90D9970
CH1 average
D9901D991109921D9931099410995109961D9971H2 average
D9902D9912D9922D9932D9942D9952D9962D9972
CH3 average
D99399130992309339943D9953D996309973
D9904D9914D9924D9934D9944D9954D9964D9974cH5 output value
D99509915D992509935D9945D99550965D9975cH6 output value
Note 1. D9900-D9999 are average input values of CHI- CH4 and the sampling range is Kl-K100
5
When the sampling range is set to K1, the values displayed in D9900- D9999 are current values.
You can use: I. ES AlO Configuration Function of WPLSoft or 2. FROM/TO instructions
(CR#8-CR#fll) to set the sampling range as KI
Adjust AD Conversion Curve
Users can adjust the conversion curves according to the actual needs by changing the
Offset value(CR#28-CR#31)and Gain value( CR#34-CR#37)
Equation for voltage input Modeo Mode 2: 0. 3125mV= 20V/64,000=10V/32, 000
Y=16000
×32000e/Gain-Oe)
Equation for voltage input Mode1 /Mode3: 0. 15625mV=10V/64,000= 5V/32, 000
Y=16000×
x 32000-Offset
5(/)
Equation for current input Mode4 Mode5: 0.625uA= 40mA/64, 000= 20mA/32, 000
y=16000×X(mA)
2m)×32000|1Gam-omer)
Y=Digital output, X=Current input
nt input Mode6: 0. 5HA= 16mA/32, 000
Adopt the equation of current input mode4/mode5, substitute Gain for 19, 200
(12mA)and Offset for 6, 400(4mA)
X(ma)
Y=1600)0m×32000640019200-6400
Y=Digital output, X=Current inpu
Mode 1
+32384
+32384
+32000
+32000
Digital
Digital
+16000
output
+16000
10V
16000
16000
Voltage input
32384
Mode o of cr#t2- crtt5
±10V,Gain=5∨(16,000, Offset=0V(0)
Mode 1 of CR#2- cR#5
5V, Gain =2.5V(16,000), Offset= OV(0)
Range of digital conversion(Max /Min )+32,000(+32, 384)
·Mode2:
·Mode3:
output
+16000
+16000
Gain
Gain
Offset 51
10
2.5V5v
6
Mode 2 of cR#2- cR#5
0-+10 V Gain=5V(16000), Offset=0V(0)
Mode 3 of cr#2- cr#t5
0-+5V,Gain=25V(16,000), Offset=0v(0)
Range of digital conversion(Max /Min )0-+32,000(-384-+32, 384)
+32384
32000
+16000
OmA
Mode 4 of cr#2- crtts
±20mA.G
mA(16,000), Offset OmA(O)
Range of digital conversion(Max /Min )#32, 000(+32, 384)
·Mode6:
+32000
+16000
+16000
10mA 20mA
4mA 12mA 20m
Offset
Offset
Current inpr
Current in put
Mode 5 of cr#2- cr#t5
0~+20mA,Gan=10mA(16.000), Offset=0mA(0)
Mode 6 of cr#2- cr#5
+4-+20mA,Gan=12mA(19,200), Offset=4mA
Range of digital conversion(Max /Min )10-+32,000 (-384+32, 384)
Adjust D/A Conversion Curve
Users can adjust the conversion curves according to the actual needs by changing the
Offset value( CR#32 -CR#33)and Gain value(CR#38-CR#39)
Equation for voltage output Mode0: 0.3125mV= 20V/64,000
Y()=Xx(Gain-Ofisen ) Offset x(o()
16000
Y=Voltage output, X=Digital input
Equation for current output Mode 1: 0.625HA= 20mA/32,000
Xx Gain-Offser
Offset (200mA)
16000
32000
Y=Current output, X=Digital input
Equation for current output Mode2: 0.5HA= 16mA/32, 000
Adopt the equation of current output Mode 1, substitute Gain for 19, 200(12mA)and
Offset for 6, 400(4mA)
7
y(mx×(90406010m
16000
10V
ge
32000
10V
Mode 0(CR#2 - CR#5)
+10V, Gain= 5V(16,000), Offset =OV(O)
Range of digital conversion(Max /Min )+32,000(-32, 768-+32, 767
Gain
outpu
10mA
+16000+32000
Mode 1(CR#2- Cr#5
0-+20mA,Gain=10mA(16.000), Offset=0mA(0)
R
of digital conversion (Max /Min )0-+32,000(0-+32, 767)
Current
64000+16000+32000
Digital in put
Mode 2(CR#2- CR#5)
4+20mA, Gain=12mA(19, 200), Offset= 4mA
(6,400)
Range of digital conversion(Max /Min ) 0-+32,000(-6400-+32, 767)
感謝您採用台達DVP系列產品DvP06XA-E2類比輸入輸出混合模粗可接受外部4點類
比信號輸廴(鼋壓或鼋流皆可)將之轉換成16位元之數位信號。類比信號輸岀部份接受
來自PLC主機的2組16位元數位資料·再將數位資料轉換鳥2點類比信號輸出(鼋壓或
電流皆可)使用者可經由配線選擇電壓輸入或鼋流輸入·並可透過主機以FROM/TO指
爷來讀寫模粗內資料·或以MO指爷直接讀取對應通道的平均值,或直接寫入對應通道
的輸出值(請參閱D9900~D9999特殊暫存器使用說明)
κ本安蜚說明書提供給使用者電氣規格丶功能規格丶安蜚配線之相關注意事項。其他詳
田之程式設計及指命說明翡見DVP-ES2操作手冊【模粗篇】·選購之周邊裝置詳細說
明請見該產品隨機安装說明書
κ本機焉開放型( OPEN TYPE)機殼·因此使用者使用本機時·必須將之安装於具防
塵丶防潮及免於電擊衝墼意外之外殼配線箱內。另必須具備保護措施(如∶特殊之工
具或鑰匙扌可打開)防止并稚護人員操作或意外衝擊本體·造成危險及損壞
κ交流輸入電源不可連接於輸入出信號端·否則可能造成嚴重損壞·請在上電之前再次
記電源配祿。睛勿在上電時觸摸任何端子。本體上之接地端子③務必正確的接地
可提高產品抗雜訊能力。
產品外觀尺寸與部位介紹
笔源A<>D及错誤指示燈
機樵型虢
脫落式斩出/入端子
/O模粗固定扣
DN軌槽
O模粗連接埠
88当
端子稱號
/O模祖接埠
61.5
外部配線
主動式輸入
重输入
1MO
CH1
11+
1M3
隔離得*1
鼋流输入
V4+
CH4
隔離得*1
授至電源模
祖之端
DC/DC
24V
轉换器A0
第三種授地(地阻抗1009以下)
9
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.