您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 西门子SIMOCODE-DP电机保护与控制设备系统手册.pdf
  所属分类: 其它
  开发工具:
  文件大小: 9mb
  下载次数: 0
  上传时间: 2019-09-14
  提 供 者: weixin_********
 详细说明:西门子SIMOCODE-DP电机保护与控制设备系统手册pdf,西门子SIMOCODE-DP电机保护与控制设备系统手册Contents Contents Figures Tables,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Introduction and notes on the manual A Description of the system Philosophy behind the SIMOCODE-DP 3UF5 system 1-2 1.2 Overview 1.3 Components of the SIMOCODE-DP system 19 1.4 System configurations ..1-10 1.5 Summary of functions Structural design of the SIMOCODE-DP system 1-12 The 3UF50 Basic Unit 2.1 Description 2-2 2.2 Summary of functions ...2-3 2.3 Outputs 2-4 2.4 Inputs 2-5 2.5 Protection functions 2.5.1 Current-dependent motor protection 2-7 2.5.2 Current Limit Value/ Blocking Protection 2-16 2.5.3 Earth Fault Detection 2-17 2.5.4 Thermistor Motor Protection 2-19 2.6 Branch control 2-21 2.6.1 Control and motor protection block 2-21 2.6.2 Information data block 2-22 2.6.3 Description of the Control stations 2-23 2.6.4 Description of the Control Functions 2-27 2.6.5 Description of the Function Block Inputs 2-47 2.6.6 Test/status LEDs 2-50 2.7 Logic modules 2-52 2.7.1 Signal Matching 2-52 2.7.2 Non-Reseting Elements on Power LoSs 2-53 2.7.3 Truth Table 31/10 2-54 2.7.4 Truth Table 51/20 2-57 2.7.5 Flash/Flicke 2-59 2.7.6 Timers 2-60 2.7.7 Counters 2-61 3 The 3UF51 Expansion Module 3 Descriptio 3-2 3.2 Summary of functions for Expansion Module 3-2 3.3 Inpu 3-3 3.4 Outputs Contents 4 The 3UF52 Operator Panel 4-1 4.1 Description 4-2 4.2 Summary of functions 4-2 4.3 Control buttons, indicator LEDs 4.4 Test/status LEDs 4-4 5 Fault Diagnosis Fault Handling Warning 5-1 5. Behaviour in the event of a fault 5-2 5.2 Acknowledgement and fault handling 5.3 Parameter Errors .5-9 5. 4 Parameterizable fault behaviour in the event of a fault 10 Communication/Data transmission 6 Introduction to the Profibus-Dp 6-2 6.1.1 Definitions 6-2 6.2 Possibilities of data transmission 6-3 6.3 Description of messages 6-5 6.4 Necessary settings for bus communication with SIMOCODE-DP 6-6 5 Decision chart for the profibus-DP connection 6-9 6.5.1 PROFIBUS-DP connections 6-9 6.5.2 SIMOCODE-DP to SIMATIC S5 With IM308-C 6-11 6.5. 3 SIMOCODE-DP to SIMATIC S7 DP master(CPU with integrated DP interface) 6-24 6.6 PROFIBUS-DP configurations 6-36 Parameterization /observation 7.1 Possible ways of parameterizing 7.1.1 Parameterizing at runtime 7-2 7.1.2 Parameterizing during starting 7-3 7.2 Basics of parameterization 7.3 Parameterizing and observing with Win-SIMOCODE-DP 7-7 7.3.1 Introduction and notes 7-7 7.3.2 After the installation 7-9 7.3.3 Program start ...,7-10 7.3.4 Menu bar .7-11 8 Engineering Example Direct Starter.......................... 8-1 8.1 Introduction 8-2 8.2 Block 1: Redrawing a conventional circuit diagram as a circuit diagram with sImocodE-DP 8-3 8.3 Block 2: Preparing a block diagram 8-11 8. 4 Block 3: Parameterization with Win-SIMOCODE-DP 8-17 GW八4NEB6314236-02 Contents A es A-1 A 1 Assignment table A-2 A 2 Active Control Stations, Contactor Controls, Lamp Controls and status messages for the control functions A-4 A 3 Control, signalling and diagnostic data A-5 A 4 Acknowledgement and Fault handling A-10 A. 5 Sketch of SIMOCODE-DP circuit diagram with basic elements A-15 A6 Block diagram of the assignments A-17 A7 Parameter table A-19 Data structure B. 1 Data formats and data record B 2 Cyclical data B-4 B.2.1 Basic Types B.3.2 Device-specific diagnosis according to DP standard B.2.2 Assignment of cyclical messages B-6 B3 Diagnosis B-8 B.3.1 Standard diagnosis B-8 B-9 B.3.3 Device-specific diagnosis according to DPV1 B-11 B.3.4 Alarms(only as s7 slave B-14 B.4 Reading/writing data records acyclically B-17 B.4.1 Reading data record 130-signals B-17 B 4.2 Reading data record 131-display/diagnosis B-19 B.4.3 Writing data record 133-statistical data B-19 B.4.4 Writing data record 132-control commands B-20 B 4.5 Data record 138-device parameter B-20 Technical Dat C1 General data C-2 C2 Auxiliary circuit /control circuit puts C.3.1 Number of inputs C-5 C.3.2 Simultaneity for Basic Unit C.3.3 Simultaneity for Expansion Module C.3.4 Input currents /cable lenghts C4 Communications interface C-6 C5 Behaviour in the event of supply-voltage failure C-6 C6 Short-circuit protection for motor branches for short-circuit currents up to 50 kA at 690 V C-7 C7 System reaction times (typical values C 8 New system functions as of product status E10 C-9 C 9 Description of DMD and type data files C-9 C 10 Source of supply for DMD and type data files Dimension Drawings D-1 Basic Unit 3UF500 /3UF501 /Expansion Module 3UF51 D2 Basic Unit 3UF502 D 3 Basic Unit 3UF503 D-4 D 4 Basic Unit 3UF504 D5 Basic Unit 3UF505 D-6 D6 Operator Panel 3UF52 GW八4NEB631428602 Contents E Typical Circuit E-1 E1 Introduction E-2 E2 Parameter Table default value E-3 E 3 Overload E-11 E.3. 1 Circuit diagram of Overload Control Function E11 E.3.2 Block diagram of Overload Control Function E12 E.3.3 Parameters of overload Control Function E-13 E 4 Direct Starter E14 E.4.1 Circuit diagram of Direct Starter Control Function E-14 E.4.2 Block diagram of Direct Starter Control Function E-15 E 4.3 Parameters of Direct starter Control Function E-16 E5 Reversing Starter .....E-17 E.5.1 Circuit diagram of Reversing Starter Control Function E17 E.5. 2 Block diagram of Reversing Starter Control Function E-18 E.5.3 Parameters of Reversing Starter Control Function E19 E6 Star Delta Starter E20 E.6.1 Circuit diagram of Star Delta Starter Control Function .E-20 E.6.2 Block diagram of Star Delta Starter Control Function E21 E 6.3 Parameters of star Delta Starter Control function E22 E7 Pole Changing starter E23 E.7.1 Circuit diagram of Pole Changing Starter Control Function E23 E.7.2 Block diagram of Pole Changing Starter Control Function E24 E73 Parameters of Pole Changing Starter Control Function E25 E 8 Dahlander Starter E26 E.8. 1 Circuit diagram of dahlander starter Control Function F26 E.8.2 Block diagram of Dahlander starter Control Function E-27 E 8.3 Parameters of dahlander starter Control function E28 E. 9 Solenoid valve E29 E.9. 1 Circuit diagram of Solenoid Valve Control Function E29 E 9.2 Block diagram of Solenoid valve Control Function E30 E 9.3 Parameters of solenoid valve control function ..,,..E31 E10 Positioner Control Function E32 E10.1 Circuit diagram of Positioner Control Function E32 E10.2 Block diagram of Positioner Control Function F34 E10.3 Parameters of Positioner Control function E35 E 11 Soft starter E36 E11.1 Circuit diagram of Soft Starter Control Function E36 E 11.2 Block diagram of Soft Starter Control Function E38 E 11.3 Parameters of soft starter Control function E39 Order Numbers G Frequently asked questions ......... G-1 G 1 General reset G-2 G 2 Win-SIMOCODE-DP fault situations in online operation G-3 Index Glossary GW八4NEB6314236-02 Figures Pa implified structure of the system 1-2 2 Layout of a motor branch(Direct Starter)using conventional technology 1-3 3 Future-oriented circuit diagram with SIMOCODE-DP 4 Reducing the amount of wiring 1-5 Data traffic over the Profibus-dP between the plc and sImoCodE-DP 1-6 5678 SIMOCODE-DP modular system 7 Win-SIMOCODE-DP 19 8 System configurations 1-10 9 Summary of functions 10 Structural design of the SIMOCODE-DP system 11 Front of basic Unit 12 Summary of functions performed by the Basic Unit 2-3 13 Diagram of output relays for basic Unit 14 Diagram of the Inputs for Basic Unit 15 Diagram of input circuitry 2-6 16 Method of assembly 2-8 17 Push-through and loop-through openings on the 3UF5001 Basic Unit 2-9 18 Circuit diagram with external current transformer 2-10 19 Tripping characteristics (cold 20 Protection of motors in potentially explosive atmospheres 2-13 21 Cooling behaviour with and without Idle Ti 2-14 22 Diagram of Earth Fault Detection 2-18 23 Diagram for Thermistor Motor Protection 2-20 24 Control and motor protection block 2-21 25 Diagram of information data block 2-22 26 Diagram of Control Stations 2-23 27 Function diagram of Torque and Limit Switches in the control of Positioners 2-35 28 Torque or Limit Switch as a changeover contact 2-42 29 Interrelationship of Uvo, UVO-Time, Grading Time and QE 2-49 30 Diagram of Signal Matching 2-52 31 Diagram of signal types 2-52 32 Diagram of Non-Reseting Elements on Power Loss 2-53 33 Diagram of Truth Tables 31/10 2-54 34 Example of a Truth Table 2-54 GW八4NEB631428602 35 EXternal circuitry/ parameters for the Truth Table example 2-55 36 Diagram of the Truth Table 51/20 2-57 37 Diagram of Flash /Flicker components 2-59 38 Diagram of Timers 2-60 39 Output behaviour of Timers 2-60 40 Diagram of the Counters .2-61 41 Front of Expansion Module 3-2 42 Summary of functions performed by the Expansion Module 3-2 43 Diagram of Inputs for Expansion Module 33 44 Diagram of Input circuitry for Expansion Module 3-3 45 Diagram of Output Relays for Expansion Module 3-4 46 Operator Panel 4-2 47 Summary of the Operator Panel's functions 4-2 48 Diagram of control buttons and indicator LEDs of the Operator Panel 49 Fast fault analysis with the "Control/Report"mask 50 Possibilities of data transmission 6-3 51 Setting parameters for DP standard 6-13 52 Enabling diagnosis according to DPV1 -16 53 Selecting SIMOCODE-DP as a dPI slave with HW Config(hardware configuration 6-25 54 Selecting SIMOCODE-DP as an S7 slave trom the hardware catalog .6-25 55 Specifying operating parameters for SIMOCODE-DP 6-26 56 Parameterizing SIMOCODE-DP via a DMD file 6-27 57 Parameterizing SIMOCODE-DP with Win-SIMOCODE-DP/Professional ..6-28 58 Enabling diagnosis according to dPVl in HW Config .6-31 59 Bus segment 6-36 60 Bus termination module 6-38 61 Setting parameters 7-4 62 Connecting free elements 7-4 63 Example for establishing connections 7-5 64 Symbols used: sockets and plugs 65 Layout of a motor branch (Direct Starter) using conventional technology 83 66 Step 2: Drawing the elements in the SIMOCODE-DP circuit diagram 8-4 7 Step 3: Deleting elements from the SIMoCODE-DP circuit diagram 8-5 68 Step 4: Deleting elements from the SIMOCODE-DP circuit diagram 8-6 69 Step 5: Drawing the elements in the SIMOCODE-DP circuit diagram 8-7 70 Step 6: Deleting elements 8-8 71 Step 7: Deleting elements 8-9 72 Step 8: Drawing the auxiliary contact of the fuse-disconnector for test operation in the simocodE-dp circuit diagram .8-10 GW八4NEB6314236-02 73 Structural layout of the SIMOCODE-DP system 8-11 74 Step 1: Drawing the external elements in the block diagram 8-13 75 Opening mask of win- SIMOCODE-DP 8-17 76 Setting the parameters in the Order Number" dialog 8-17 77 Setting parameters in the Overload" dialog 8-18 78 Setting parameters in the "Sensor" dialog 8-18 79 Setting the parameters in the Motor" dialog 8-19 80 Setting parameters in the " Control Stations"dialog 8-19 81 Parameters set in the "Control Stations" dialog 8-20 82 Operator Enabling" dialog 8-20 83 Setting CST in the Function Block Inputs" dialog 8-21 84 Setting Out 1-Output Relay in the Device Outputs/LEDs"dialog 8-21 85 Setting the address in the "Bus ProFibUs-DP dialog 8-22 86 Diagram of Basic Types B-4 87 Diagram of process data 88 Diagram of process data for basic types 2 and 3 89 Alarm sequence B-14 90 Dimension drawings for the 3UF500 /3UF501/3UF51 D-2 91 Dimension drawings for the 3UF502 D-3 92 Dimension drawings for the 3UF503 D-4 93 Dimension drawings for the 3UF504 D-5 94 Dimension drawings for the 3UF505 D-6 95 Dimension d for the 3UF52 D-7 VIll GW八4NEB6314236-02
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: