您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 西门子SIMATIC S5-135U/155U系统手册.pdf
  所属分类: 其它
  开发工具:
  文件大小: 3mb
  下载次数: 0
  上传时间: 2019-09-14
  提 供 者: weixin_********
 详细说明:西门子SIMATIC S5-135U/155U系统手册pdf,西门子SIMATIC S5-135U/155U系统手册Contents 1 Notes on Using this Manual and on the CE Symbol 11 Notes on Using this manual Notes on the CE Symbol Notes for machine manufacturers 1-6 Safety Notes 2 Centralized and Distributed Configuration of a Programmable Controller 2.1 Application 2-2 Centralized and distributed configuration 2. 2.1 Installing a PLC with Centralized Configuration 2.2.2 Installing a PLC with Distributed Configuration 2-5 2.3 EXamples 3 Installation Guidelines 3-1 3.1 Principles of Installation of Systems for EMC 3.1.1 Overview of Possible T ypes of Interterence 3.1.2 The most Important basic rules for ensuring emc 3-6 3.2 Installation of programmable controllers for Emc 3-8 3.2.1 Basic Rules for Assembling and Grounding the Inactive Metal Parts 38 3.2.2 Example of Cabinet Assembly for EMC 3.2.3 Example of Rack and Wall Mounting for EMC 3-11 3.3 Wiring of Programmable Controllers for EMC 翻B 3-12 3.3.1 Routing of Cables ..3-12 3.3.2 Equipotential Bonding 3-14 3.3.3 Shielding of Cables 3-15 3.3.4 Special Measures for Interference-Free Operation 3-17 3.3.5 Checklist for the Electromagnetically Compatible Installation of Control Systems 3-19 3.4 Power Supplies for Programmable Controllers and /Os 3-20 3. 4.1 Power Supplies for Control Systems with SIMATIC S5 3-20 3.4.2 Connecting the Programmable Controller and Load Power 3-2 3.4.3 Connecting Non-Floating or Floating Modules 326 3.5 Interference-Free Installation of centralized and Distributed interface Circuits 3 3.5.1 Interference-Free Installation of centralized Interface circuits 3-28 3.5.2 nterference-Free Installation of distributed interface circuits Interference-Free Connection of monitors 3-30 System Manual C79000-G8576-C199-07 Contents 3.6.1 Interference-Free Connection of a monitor to the cp of the S5 Controller 3-30 3.6.2 Shielding and Grounding 3-31 3.7 Selection and installation of cabinets with sImatic s5 3-33 3.7.1 Types of Cabinet 3-34 3.7.2 Clearances in cabinets 3-34 3.7.3 Removal of Power Dissipation from Cabinets 3-37 3.7.4 Examples for Determining the Type of Cabinet 3-38 3.7.5 Determining the Power Dissipation of Modules 3-39 4 Central Controllers and Expansion Units Power Supply Units.......4-1 4.1 S5-1350/155U Central controller 4.1.1 Technical Description 4-2 4.1.2 Installation 4-6 4.1 Start 4-10 4.1.4 Repair Guidelines 4-12 4.1.5 Technical Specifications 4-13 Expansion Units 4-15 4.2.1 Technical Description of the expansion Units .4-16 4.2.2 Installing the Expansion Units 4-18 4.2.3 Technical Specifications of the Expansion Units 4-18 4.3 Power Supply Units 4-19 4.3.1 Product Overview 4-19 4.3.2 Setting and Connecting the Power Supply Unit 4-23 4.3.3 Fault Indications/Fault Diagnostics 4-36 4.3.4 Maintenance and Repairs 4-40 4.3.5 Description of Internal Sequences in the Power Supply Unit 4-49 4.3.6 Technical Specifications of the Power Supply Units 4-51 4.4 6ES5 955-3NA12 Power Supply Unit 4-57 4.4.1 Technical Descripti Setting the power Supply Unit, 4-57 4.4.2 4-60 44.3 nstallation 4-63 4.4.4 Operation 翻翻面 翻面 4-64 4.4.5 Maintenance 4-66 4.4.6 Technical Specifications 4-68 4 Fan submodules 4-70 4.5. Technical Description 4-70 4.5.2 Setting and Connecting the Fan Submodule 4-72 4.5.3 Technical Specifications 4-74 System Manual c79000-G8576-c199-07 Contents 5 CPUs, Memory Cards, Memory Submodules, Interface Submodules CPU 948B-3UA13 or CPU 948B-3UA23 5-2 5.1.1 Technical Description 5.1.2 Installation and Startup 5.1.3 nterfaces of the cpu 948 5-13 5. 1. 4 Technical Specifications 5-15 5.2 CPU 948 5-17 5.2.1 Technical Description ..5-17 5.2.2 Installation and Startup 5-18 5.2.3 Interfaces of the cpu 948 5-27 5.2.4 Technical Specifications 2 5.3 CPU 928B-30B21 5 5.3.1 Technical Description 5-30 5.3.2 Installation and Startup 5-33 5.3.3 Technical Specifications 5-40 5.4 CPU 928B 5-42 5.4.1 Technical Description 5-42 5. 4.2 Installation and Startup 5-45 5.4.3 Technical Specifications 5-52 55 CPU 928-3UA21 5-54 5.5.1 Technical Description 554 5.5.2 Installation and Startup 5-56 5.5.3 Technical Specifications 5-61 5.6 CPU 928 5-62 5.6.1 Technical Description 5-62 5.6.2 Installation and Startup ..5-64 5.6.3 Technical Specifications 5-70 CPU 922 5-71 5.7.1 Technical Description ..5-71 5.7.2 Installation and Startup 5-73 5.7.3 Technical Specifications 5-79 374 Flash EProm cards ..5-80 58.1 Technical Description 5.8.2 Notes on Operation 5-80 5.8.3 Technical Specifications 5-81 59 376 Memory submodules 582 5.9.1 Technical Description ..5-82 5.9.2 Notes on Operation 5-82 5.9.3 Technical Specifications 5-83 5.10 377 Memory Submodules 5-84 5.10.1 Technical Description .5-84 5. 10.2 Notes on Operation 5-84 5. 10.3 RAM Submodules with Battery Backup 5-85 5.10.4 Technical Specifications 5-90 5.11 nterface submodules ..5-92 5.11.1 Installing and Removing the Interface Submodules 593 5.11.2 PG Submodule 5-95 System Manual C79000-G8576-C199-07 Contents 5.11.3 V24 Submodule 5-99 5.114 TTY Submodule 5-106 5.11.5RS422A485 Submodule..,,,,,,,, 5-112 5.11.6 SINEC L1 Submodule 5-118 5.11.7 Technical Specifications of the Interface Submodules 5-122 Multiprocessor Operation/Coordinators 6.1 Introduction 6-2 6.2 Starting the Multiprocessor Operation 6.3 Coordinator modes 6-13 6.4 923A Coordinator Module(is no longer supplied) 6.4.1 Technical Description 6-15 6.4.2 Settings on the coordinator 6-17 6.5 923C Coordinator module 6-18 6.5.1 Technical Description 6-18 6.5.2 Settings on the Coordinator 6-23 6.6 Technical Specifications of the Coordinators 6-28 7 Interface Modules 7 7.1 The 300 and 312 Interface modules 72 7.1.1 Indicators and controls 7.1.2 Modes/Jumper assignments of the IM 300 7-5 7.2 The 30 1 and 310 Interface modules 7-10 7.2.1 Indicators and controls 7-1 7. 2.2 Modes/Jumper Assignments of the IM 301..........................7-12 The 304 and 3 14 Interface modules 7-14 73.1 Indicators and controls Mdes/ Jumper Assignments of the iM314,.·…,` 7-15 7.3.2 Modes/Jumper Assignments of the IM 304 7-16 7-18 7.4 Technical specifications 7-21 7.4.1 6ES5 721 Connecting Cable 7-2 742 6ES5 7602 Terminator 7-23 8 Digital Input/Output Modules∴∴ 8-1 8.1 Technical Description 翻面副 8-2 8.1.1 Design 8-4 8.1.2 Function of the Enable Inputs 8.1.3 Special features of the 432 digital Input module 8-8 8.1.4 Special Features of the DI/DQ 482 8-12 8.2 Installation and startup 8-14 8.2.1 Setting the Module Address .· 8-14 8.2.2 Removing and Inserting Modules 8-18 8.2.3 Marking of Modules 8-20 8.2.4 Connecting the signal lines 8-21 8.2.5 Connection of Outputs in Parallel and Switching On the load via a contact 8-22 8.2.6 Short-Circuit Protection and Fusing 8-24 8.2.7 Quenching for Inductive loads 8-25 System Manual c79000-G8576-c199-07 Contents 8.3 Common Technical Specifications 828 8.4 Specification Sheets for the Modules 8-30 8.4.1 6ES5 420-4UA13/4UA14 Digital Input Module 8-30 8.4.2 6ES5 430-4UA13/4UA 14 Digital Input Module 8-32 8.4.3 6ES5 431-4UA12 Digital Input Modr 8-34 8.4.4 6ES5 432-4UA12 Digital Input Module 8-36 8.4.5 6ES5 434-4UA12 Digital Input Module 8-39 8.4.6 6ES5 435-4UA12 Digital Input Module 8-42 8. 4.7 6ES5 436-4UA12 Digital Input Module 8-44 8.4.8 6ES5 436-4UB 12 Digital Input Module 8-46 8.4.9 6ES5 441-4UA13 /4UA14 Digital Output Module 8-48 8.4.10 6ES5 451-4UA13/4UA14 Digital Output module 8-50 8.4.11 6ES5 453-4UA12 Digital Output Module 8.4.12 6ES5 454-4UA13/4UA14 Digital Output Module .8-52 8-54 8.4.13 6ES5 455-4UA12 Digital Output Module 8-56 8. 4.14 6ES5 456-4UA12 Digital Output Module 8-58 8.4.15 6ES5 456-4UB 12 Digital Output Module 8-60 8.4.16 6ES5 457-4UA12 Digital Output Module 8-62 8. 4.17 6ES5 458-4UA12 Digital Output Module 8-64 8.4.18 6ES5 458-4UC11 Digital Output Module 8-67 8.4.19 6ES5 482-4UA11 Digital Input/Output Module 8-69 9 Analog Input/Output Modules 91 9.1 Technical description 9.2 Common Technical Specifications 9-3 9.3 The 460 Analog Input Module .94 9.3.1 Design 9 9.3.2 Function of the Enable Inpl 9.3.3 Special Features of the 460 Analog Input Module 9-8 9.3.4 Setting the Module Address 9-10 9.3.5 Removing and Inserting Modules 9-13 9.3.6 Marking of Modules and Front Connectors 9-15 9.3.7 Connecting the Signal Lines 9-16 9.3.9 Connecting a Compensating Box for Thermal E M.F. Measurement..9-17 9.3.8 Connection of sensors 9-19 9.3.10 Connecting Resistance Thermometers in the Standard Pt 100 Range..9-20 9.3.11 Connecting Resistance Thermometers in the Extended Pt 100 Range 9-21 9.3.12 Broken Wire signal 9-22 9.3.13 Connecting Transducers 9-23 9.3. 14 Measured-Value Representation 924 9.3.15 Technical Specifications 9-29 94 The 463 Analog Input Module …935 9. 4.1 Design 935 9.4.2 Function of the Enable Input 9-35 9. 4.3 Special Features of the 463 Analog Input Module 9-39 9.4.4 Setting the Module Address 939 9. 4.5 Removing and Inserting Modules 9-42 9.4.6 Marking of Modules and Front Connectors 9-44 9. 4.7 Connecting the Signal Lines 9-45 9.4.8 Measured-Value Representation 9-46 9. 4.9 Technical Specifications 9-47 ystem C79000-G8576-C199-07 Contents 9.5 The 465 Analog input Module 9-50 9.5 Design 9-50 9.5.2 Function of the Enable Input 9-50 9.5. 3 Special Features of the 465 Analog Input Module 9-54 9.5.4 Setting the Module Address 9-56 9.5.5 Removing and Inserting Modules 9-59 9.5.6 Marking of Modules and front connectors 9-61 9.5.7 Connecting the signal Lines 9-62 9.5.8 Connecting a Compensating Box for Thermal E.M. F. Measurement 9-63 9.5.9 Connecting Resistance Thermometers to the 465 Analog Input Module.9-64 9.5. 10 Broken Wire Signal for Resistance Thermometers 9-66 9.5.11 Connecting Transducers 9-67 9.5. 12 Measured-Value Representation 9-68 9.5.13 Technical Specifications 9-72 9.6 The 466 Analog Input Module 9-77 9.6. Design 9.6.2 Special Features of the 466 Analog Input Module 9-77 9.6.3 Startup for Analog Input 466-3LA11 9.6.4 Startup for Analog Input 466-4UA11 9-84 9.6.5 Removing and Inserting Modules 9-91 9.6.6 Marking of Modules and Front Connectors 9-93 9.6.7 Connecting the Signal Lines 9-94 9.6.8 Connecting sensors to the 466 Analog input module 995 9.6. 9 Measured-Value Representation 9-98 9.6.10 Technical Specifications 9-102 9.7 The 470 Analog output module ...9-106 9.7.1 Design 9-106 9.7.2 Function of the Enable Input 9-106 9.7.3 Special Features of the 470 Analog Output Module 9-110 9.7.4 Setting the Module Address 9-110 9.7.5 Removing and Inserting Modules 9-113 9.7.6 Marking of Modules and Front Connectors 9-115 9.7.7 Connecting the Signal Lines 9-116 9.7.8 Connecting Loads to the 470 Analog Output Module 9-117 9.7.9 Measured-Value Representation 9-119 9.7.10 Technical Specifications 9-120 10 Monitoring Module 10-1 10.1 Application 10-2 10.1.1 Design 10-2 10.1.2 Mode of Operation 10-3 10.1.3 Block Diagram 10-3 10.1.4 Fault detection 104 10.1.5 Resetting 10-5 10.2 nstallation 10-6 10.2.1 Possible Configurations .10-6 10.2.2 Removing and Inserting 10-6 10.2.3 Connecting the RESET Input 10-7 10.2.4 Switch Positions of the Relay contact 10-7 10.2.5 Installation Guidelines 10-7 10.3 Operation 10-8 System Manual c79000-G8576-c199-07 Contents 10.3.1 Addressing ._10-10 10.3.2 Setting the Address Switches S1, S2, S3, S4 10-12 10.3.3 Setting the Switch S5 10-13 10.4 Technical Specifications 10-14 10.5 Address table 10-16 11 Connector Assignments 111 Appendix A-1 B Guidelines for Handling Electrostatically-Sensitive Devices(ESD).....B-1 B.1 What is EsD? B.2 Electrostatic Charging of Persons B.3 General protective Measures against electrostatic discharge damage B-4 Index Index-1 ystem C79000-G8576-C199-07 System Manual c79000-G8576-c199-07
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: