文件名称:
西门子SIMATIC S5-135U/155U系统手册.pdf
开发工具:
文件大小: 3mb
下载次数: 0
上传时间: 2019-09-14
详细说明:西门子SIMATIC S5-135U/155U系统手册pdf,西门子SIMATIC S5-135U/155U系统手册Contents
1 Notes on Using this Manual and on the CE Symbol
11
Notes on Using this manual
Notes on the CE Symbol
Notes for machine manufacturers
1-6
Safety Notes
2 Centralized and Distributed Configuration of a Programmable Controller
2.1
Application
2-2
Centralized and distributed configuration
2. 2.1 Installing a PLC with Centralized Configuration
2.2.2 Installing a PLC with Distributed Configuration
2-5
2.3
EXamples
3 Installation Guidelines
3-1
3.1
Principles of Installation of Systems for EMC
3.1.1 Overview of Possible T ypes of Interterence
3.1.2 The most Important basic rules for ensuring emc
3-6
3.2
Installation of programmable controllers for Emc
3-8
3.2.1 Basic Rules for Assembling and Grounding the Inactive Metal
Parts
38
3.2.2 Example of Cabinet Assembly for EMC
3.2.3 Example of Rack and Wall Mounting for EMC
3-11
3.3
Wiring of Programmable Controllers for EMC
翻B
3-12
3.3.1 Routing of Cables
..3-12
3.3.2 Equipotential Bonding
3-14
3.3.3 Shielding of Cables
3-15
3.3.4 Special Measures for Interference-Free Operation
3-17
3.3.5 Checklist for the Electromagnetically Compatible Installation
of Control Systems
3-19
3.4
Power Supplies for Programmable Controllers and /Os
3-20
3. 4.1 Power Supplies for Control Systems with SIMATIC S5
3-20
3.4.2 Connecting the Programmable Controller and Load Power
3-2
3.4.3 Connecting Non-Floating or Floating Modules
326
3.5
Interference-Free Installation of centralized and
Distributed interface Circuits
3
3.5.1 Interference-Free Installation of centralized Interface circuits
3-28
3.5.2 nterference-Free Installation of distributed interface circuits
Interference-Free Connection of monitors
3-30
System Manual
C79000-G8576-C199-07
Contents
3.6.1 Interference-Free Connection of a monitor to the cp of the
S5 Controller
3-30
3.6.2 Shielding and Grounding
3-31
3.7
Selection and installation of cabinets with sImatic s5
3-33
3.7.1 Types of Cabinet
3-34
3.7.2 Clearances in cabinets
3-34
3.7.3 Removal of Power Dissipation from Cabinets
3-37
3.7.4 Examples for Determining the Type of Cabinet
3-38
3.7.5 Determining the Power Dissipation of Modules
3-39
4 Central Controllers and Expansion Units Power Supply Units.......4-1
4.1
S5-1350/155U Central controller
4.1.1 Technical Description
4-2
4.1.2 Installation
4-6
4.1
Start
4-10
4.1.4 Repair Guidelines
4-12
4.1.5 Technical Specifications
4-13
Expansion Units
4-15
4.2.1
Technical Description of the expansion Units
.4-16
4.2.2 Installing the Expansion Units
4-18
4.2.3 Technical Specifications of the Expansion Units
4-18
4.3
Power Supply Units
4-19
4.3.1 Product Overview
4-19
4.3.2 Setting and Connecting the Power Supply Unit
4-23
4.3.3 Fault Indications/Fault Diagnostics
4-36
4.3.4 Maintenance and Repairs
4-40
4.3.5 Description of Internal Sequences in the Power Supply Unit
4-49
4.3.6 Technical Specifications of the Power Supply Units
4-51
4.4
6ES5 955-3NA12 Power Supply Unit
4-57
4.4.1 Technical Descripti
Setting the power Supply Unit,
4-57
4.4.2
4-60
44.3 nstallation
4-63
4.4.4 Operation
翻翻面
翻面
4-64
4.4.5 Maintenance
4-66
4.4.6 Technical Specifications
4-68
4
Fan submodules
4-70
4.5.
Technical Description
4-70
4.5.2 Setting and Connecting the Fan Submodule
4-72
4.5.3 Technical Specifications
4-74
System Manual
c79000-G8576-c199-07
Contents
5 CPUs, Memory Cards, Memory Submodules, Interface Submodules
CPU 948B-3UA13 or CPU 948B-3UA23
5-2
5.1.1 Technical Description
5.1.2 Installation and Startup
5.1.3 nterfaces of the cpu 948
5-13
5. 1. 4 Technical Specifications
5-15
5.2
CPU 948
5-17
5.2.1
Technical Description
..5-17
5.2.2 Installation and Startup
5-18
5.2.3 Interfaces of the cpu 948
5-27
5.2.4 Technical Specifications
2
5.3
CPU 928B-30B21
5
5.3.1 Technical Description
5-30
5.3.2 Installation and Startup
5-33
5.3.3 Technical Specifications
5-40
5.4
CPU 928B
5-42
5.4.1 Technical Description
5-42
5. 4.2 Installation and Startup
5-45
5.4.3 Technical Specifications
5-52
55
CPU 928-3UA21
5-54
5.5.1
Technical Description
554
5.5.2 Installation and Startup
5-56
5.5.3 Technical Specifications
5-61
5.6
CPU 928
5-62
5.6.1 Technical Description
5-62
5.6.2 Installation and Startup
..5-64
5.6.3 Technical Specifications
5-70
CPU 922
5-71
5.7.1 Technical Description
..5-71
5.7.2 Installation and Startup
5-73
5.7.3 Technical Specifications
5-79
374 Flash EProm cards
..5-80
58.1
Technical Description
5.8.2 Notes on Operation
5-80
5.8.3 Technical Specifications
5-81
59
376 Memory submodules
582
5.9.1 Technical Description
..5-82
5.9.2 Notes on Operation
5-82
5.9.3 Technical Specifications
5-83
5.10 377 Memory Submodules
5-84
5.10.1 Technical Description
.5-84
5. 10.2 Notes on Operation
5-84
5. 10.3 RAM Submodules with Battery Backup
5-85
5.10.4 Technical Specifications
5-90
5.11
nterface submodules
..5-92
5.11.1 Installing and Removing the Interface Submodules
593
5.11.2 PG Submodule
5-95
System Manual
C79000-G8576-C199-07
Contents
5.11.3 V24 Submodule
5-99
5.114 TTY Submodule
5-106
5.11.5RS422A485 Submodule..,,,,,,,,
5-112
5.11.6 SINEC L1 Submodule
5-118
5.11.7 Technical Specifications of the Interface Submodules
5-122
Multiprocessor Operation/Coordinators
6.1
Introduction
6-2
6.2
Starting the Multiprocessor Operation
6.3
Coordinator modes
6-13
6.4
923A Coordinator Module(is no longer supplied)
6.4.1 Technical Description
6-15
6.4.2 Settings on the coordinator
6-17
6.5
923C Coordinator module
6-18
6.5.1 Technical Description
6-18
6.5.2 Settings on the Coordinator
6-23
6.6
Technical Specifications of the Coordinators
6-28
7 Interface Modules
7
7.1
The 300 and 312 Interface modules
72
7.1.1
Indicators and controls
7.1.2 Modes/Jumper assignments of the IM 300
7-5
7.2
The 30 1 and 310 Interface modules
7-10
7.2.1
Indicators and controls
7-1
7. 2.2 Modes/Jumper Assignments of the IM 301..........................7-12
The 304 and 3 14 Interface modules
7-14
73.1 Indicators and controls
Mdes/ Jumper Assignments of the iM314,.·…,`
7-15
7.3.2 Modes/Jumper Assignments of the IM 304
7-16
7-18
7.4
Technical specifications
7-21
7.4.1 6ES5 721 Connecting Cable
7-2
742 6ES5 7602 Terminator
7-23
8 Digital Input/Output Modules∴∴
8-1
8.1
Technical Description
翻面副
8-2
8.1.1 Design
8-4
8.1.2 Function of the Enable Inputs
8.1.3 Special features of the 432 digital Input module
8-8
8.1.4 Special Features of the DI/DQ 482
8-12
8.2
Installation and startup
8-14
8.2.1 Setting the Module Address
.·
8-14
8.2.2 Removing and Inserting Modules
8-18
8.2.3 Marking of Modules
8-20
8.2.4 Connecting the signal lines
8-21
8.2.5 Connection of Outputs in Parallel and Switching On the load via
a contact
8-22
8.2.6 Short-Circuit Protection and Fusing
8-24
8.2.7 Quenching for Inductive loads
8-25
System Manual
c79000-G8576-c199-07
Contents
8.3
Common Technical Specifications
828
8.4
Specification Sheets for the Modules
8-30
8.4.1 6ES5 420-4UA13/4UA14 Digital Input Module
8-30
8.4.2 6ES5 430-4UA13/4UA 14 Digital Input Module
8-32
8.4.3 6ES5 431-4UA12 Digital Input Modr
8-34
8.4.4 6ES5 432-4UA12 Digital Input Module
8-36
8.4.5 6ES5 434-4UA12 Digital Input Module
8-39
8.4.6 6ES5 435-4UA12 Digital Input Module
8-42
8. 4.7 6ES5 436-4UA12 Digital Input Module
8-44
8.4.8 6ES5 436-4UB 12 Digital Input Module
8-46
8.4.9 6ES5 441-4UA13 /4UA14 Digital Output Module
8-48
8.4.10 6ES5 451-4UA13/4UA14 Digital Output module
8-50
8.4.11 6ES5 453-4UA12 Digital Output Module
8.4.12 6ES5 454-4UA13/4UA14 Digital Output Module
.8-52
8-54
8.4.13 6ES5 455-4UA12 Digital Output Module
8-56
8. 4.14 6ES5 456-4UA12 Digital Output Module
8-58
8.4.15 6ES5 456-4UB 12 Digital Output Module
8-60
8.4.16 6ES5 457-4UA12 Digital Output Module
8-62
8. 4.17 6ES5 458-4UA12 Digital Output Module
8-64
8.4.18 6ES5 458-4UC11 Digital Output Module
8-67
8.4.19 6ES5 482-4UA11 Digital Input/Output Module
8-69
9
Analog Input/Output Modules
91
9.1
Technical description
9.2
Common Technical Specifications
9-3
9.3
The 460 Analog Input Module
.94
9.3.1 Design
9
9.3.2 Function of the Enable Inpl
9.3.3 Special Features of the 460 Analog Input Module
9-8
9.3.4 Setting the Module Address
9-10
9.3.5 Removing and Inserting Modules
9-13
9.3.6 Marking of Modules and Front Connectors
9-15
9.3.7 Connecting the Signal Lines
9-16
9.3.9 Connecting a Compensating Box for Thermal E M.F. Measurement..9-17
9.3.8 Connection of sensors
9-19
9.3.10 Connecting Resistance Thermometers in the Standard Pt 100 Range..9-20
9.3.11 Connecting Resistance Thermometers in the Extended Pt 100 Range
9-21
9.3.12 Broken Wire signal
9-22
9.3.13 Connecting Transducers
9-23
9.3. 14 Measured-Value Representation
924
9.3.15 Technical Specifications
9-29
94
The 463 Analog Input Module
…935
9. 4.1 Design
935
9.4.2 Function of the Enable Input
9-35
9. 4.3 Special Features of the 463 Analog Input Module
9-39
9.4.4 Setting the Module Address
939
9. 4.5 Removing and Inserting Modules
9-42
9.4.6 Marking of Modules and Front Connectors
9-44
9. 4.7 Connecting the Signal Lines
9-45
9.4.8 Measured-Value Representation
9-46
9. 4.9 Technical Specifications
9-47
ystem
C79000-G8576-C199-07
Contents
9.5
The 465 Analog input Module
9-50
9.5
Design
9-50
9.5.2 Function of the Enable Input
9-50
9.5. 3 Special Features of the 465 Analog Input Module
9-54
9.5.4 Setting the Module Address
9-56
9.5.5 Removing and Inserting Modules
9-59
9.5.6 Marking of Modules and front connectors
9-61
9.5.7 Connecting the signal Lines
9-62
9.5.8 Connecting a Compensating Box for Thermal E.M. F. Measurement
9-63
9.5.9 Connecting Resistance Thermometers to the 465 Analog Input Module.9-64
9.5. 10 Broken Wire Signal for Resistance Thermometers
9-66
9.5.11 Connecting Transducers
9-67
9.5. 12 Measured-Value Representation
9-68
9.5.13 Technical Specifications
9-72
9.6 The 466 Analog Input Module
9-77
9.6.
Design
9.6.2 Special Features of the 466 Analog Input Module
9-77
9.6.3 Startup for Analog Input 466-3LA11
9.6.4 Startup for Analog Input 466-4UA11
9-84
9.6.5 Removing and Inserting Modules
9-91
9.6.6 Marking of Modules and Front Connectors
9-93
9.6.7 Connecting the Signal Lines
9-94
9.6.8 Connecting sensors to the 466 Analog input module
995
9.6. 9 Measured-Value Representation
9-98
9.6.10 Technical Specifications
9-102
9.7
The 470 Analog output module
...9-106
9.7.1 Design
9-106
9.7.2 Function of the Enable Input
9-106
9.7.3 Special Features of the 470 Analog Output Module
9-110
9.7.4 Setting the Module Address
9-110
9.7.5 Removing and Inserting Modules
9-113
9.7.6 Marking of Modules and Front Connectors
9-115
9.7.7 Connecting the Signal Lines
9-116
9.7.8 Connecting Loads to the 470 Analog Output Module
9-117
9.7.9
Measured-Value Representation
9-119
9.7.10 Technical Specifications
9-120
10 Monitoring Module
10-1
10.1
Application
10-2
10.1.1 Design
10-2
10.1.2 Mode of Operation
10-3
10.1.3 Block Diagram
10-3
10.1.4 Fault detection
104
10.1.5 Resetting
10-5
10.2
nstallation
10-6
10.2.1 Possible Configurations
.10-6
10.2.2 Removing and Inserting
10-6
10.2.3 Connecting the RESET Input
10-7
10.2.4 Switch Positions of the Relay contact
10-7
10.2.5 Installation Guidelines
10-7
10.3 Operation
10-8
System Manual
c79000-G8576-c199-07
Contents
10.3.1 Addressing
._10-10
10.3.2 Setting the Address Switches S1, S2, S3, S4
10-12
10.3.3 Setting the Switch S5
10-13
10.4 Technical Specifications
10-14
10.5
Address table
10-16
11 Connector Assignments
111
Appendix
A-1
B Guidelines for Handling Electrostatically-Sensitive Devices(ESD).....B-1
B.1
What is EsD?
B.2
Electrostatic Charging of Persons
B.3
General protective Measures against electrostatic discharge damage
B-4
Index
Index-1
ystem
C79000-G8576-C199-07
System Manual
c79000-G8576-c199-07
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.