详细说明:西门子SIMOTION辅助功能件说明书pdf,西门子SIMOTION辅助功能件说明书Preface
Scope
This manual describes the supplementary SINAMINCS system components in use under
SiMOTION D or under sinamics s120 in connection with simotion c.p or d
This manual is aimed at machine manufacturers plant engineers commissioning personnel,
and service personnel who use SINAMICS or who use SIMOTIon in connection with
SINAMICS
Sections in this manual
The following is a list of chapters included in this manual along with a description of the
information presented in each chapter
System overvie
Provides information about the applications, versions, and integration of the hardware
components of the SINAMICS S system in connection with operation under SIMOTION
Components
Description
Provides a brief description of each system component and its interfaces
Interfaces
Provides information about the different interfaces of the devices, their pin
assignment, and possible applications
Installation/Mounting
Provides information about installation and uninstallation of the devices
Electrical connection
Provides information about the electrical connection of system components
echnical data
Provides information about the relevant technical data for the device
Appendix
Provides information about spring-loaded terminals/screw-type terminals, the eC
Declaration of Conformity, and the Esd guidelines
Additional SINAMICS System Components for SIMOTION
Manua,03/2007
尸re日ace
SiMOtION documentation
An overview of the simotion documentation can be found in a separate list of references
The list of references is supplied on the "SIMOTION SCOUT" CD
The SiMotion documentation consists of 9 documentation packages containing
approximately 60 SIMOTION documents and documents on other products(e.g
SINAMICS)
The following documentation packages are available for SIMOTION V4. 1
SIMOTION Engineering System
SIMOTION System and Function Descriptions
SIMOTION Diagnostics
SIMOTION Programming
SIMOTION Programming-References
SIMOTION C2XX
SIMOTION P350
SIMOTION D4xX
SIMOTION Supplementary Documentation
This manual is part of the SIMOTION supplementary documentation package
If you have any technical questions, please contact our hotline(worldwide)
A&D Technical Support
Phone:+49(180)5050222
Fax:+49(180)5050223
E-mail: adsupportsiemens.COl
Internet:http://www.siemens.de/automation/support-request
If you have any questions, suggestions, or corrections regarding the documentation, please
fax or e-mail them to
Fax:+49(9131)9863315
E-mail:documotioncontrolsiemens.com
Siemens Internet address
The latest information about SIMOTION products, product support, and FAQs can be found
on the internet at
· General information
http://www.slemens.de/slmotion(german)
http://www.slemens.com/simotlon(international)
Product support
http://supportautomationsiemenscom/w/view/en/10805436
Additional SINAMICS System Components for SIMOTION
Manua,03/2007
尸re日ace
Additional support
We also offer introductory courses to help you familiarize yourself with SIMOTION
Please contact your regional training center or our main training center at D-90027
Nuremberg, phone +49(911)895 3202
Safety Instruction
Danger
Commissioning shall not start until it has been absolutely ensured that the machine in which
the components described here are to be installed complies with Directive 98/37/EC
SINAMICS Sequipment must only be commissioned by suitably qualified personnel
The personnel must take into account the information provided in the technical customer
documentation for the product, and be familiar with and observe the specified danger and
warning notices
Operation of electrical equipment and motors inevitably involves electrical circuits with
dangerous voltages
Dangerous mechanical movements may occur in the system during operation
All work on the electrical system may only be carried-out when the system has been
disconnected from the power supply and locked-out so that it cannot be accidently restarted
△
Warning
Safe, problem-free operation of SINAMICS S equipment assumes proper transportation
storage, setup, and installation, as well as careful operation and maintenance
Information contained in catalogs and quotations also apply to the special equipment version
In addition to the danger and warning information provided in the technical customer
documentation, the applicable national, local, and plant-specific regulations and
requirements must be taken into account
Only protective extra-low voltages(PELV that comply with EN60204-1 may be connected to
all connections and terminals between 0 and 48V
Caution
Operating the equipment in the immediate vicinity(<1.5 m)of mobile telephones with a
transmitter power of> 1 W may lead to incorrect operation
Additional SINAMICS System Components for SIMOTION
Manua,03/2007
Table of contents
Preface
Introduction
13
1.1
Application
13
Product variants
14
1.3
Overview
Integration of drive I/O….……
16
15
Expansion of the drive-side computer performance with CX32
System data
19
2 Terminal module TM15
幽血自自着自曲曲曲面曲曲
b自鲁曲曲自B自自自自自自自自自
23
2.1
Description
2.2
Safety Information
23
2.3
Description of Ports
24
2.3.1 Overview
2.3.2 Connection example
25
2.3.3 X500 and X501 DRIVE-CLiQ interface
26
2.3.4 X524 Electronic power supply
26
2.3.5 X520 digital inputs/outputs
28
2.3.6X521 digital inputs/ outputs…,…,
28
2.3.7 X522 digital inputs/outputs
2.3.8 Description of the LEDs on the Terminal Module TM15
2.4
Dimension Drawing
30
2.5
2.6
Electrical Connection
32
2.7
Commissioning
34
2.8
Technical specifications
34
3 Terminal Module TM17 High Feature
自白B"白自 O dEEEEE
37
Description
37
3.2
Safety Information
37
3.3
Description of Ports
38
3.3.1 Overview
38
3.3.2
sam
ple connection
.39
3.3.3×500and×501 DRIVE-CLiQ interface
1,B
40
3.3.4 X524 Electronic power supply
...::.:::::.:
3.3.5 X520 digital inputs/outputs
42
3.3.6 X521 digital inputs/outputs
…42
3.3.7 X522 digital inputs/outputs
43
3.3.8 Description of the Leds on Terminal module TM17 High Feature
Additional SINAMICS System Components for SIMOTION
Manua,03/2007
7
Table of contents
3.4
Dimension drawing…
44
3.5
Installation
44
3.6
Electrical Connection
46
Commissioning…
48
3.8
Technical data
48
Terminal Module TM31
E■■■口D1
51
4.1
Description
51
4.2
Safety Information…………
4.3
Interface description
.52
Overview
4.3.2 Connection example
4.3.3×500and×501 DRIVE-CLiQ interface
4
4.3. 4 Electronics power supply X524...
54
435 Digital inputs×520
5
43.6 Digital inputs530……
55
4.3.7 Auxiliary voltage for the digital inputs X540
56
4.3.8 Analog inputs X521
4.3. 9 S5 current/voltage changeover switch for analog inputs
57
4.3. 10 Analog outputs/temperature sensor connection X522
8
4.3.1 1 X541 bidirectional digital inputs/outputs
58
4.3. 12 Relay outputs X542
9
4.3.13 Description of the LEDs on the Terminal Module TM31...
60
4.4
Dimension drawing ...
61
4.5
Installation
…61
4
Electrical connection
63
4.7
Commissioning
64
Technical specifications
65
5 Terminal Module TM41
5.1
Description…
67
5.2
Safety Information
67
Interface description
5.3.1 Overview
68
5.3.2 Connection example
69
5.3.3 X500 and X501 DRIVE-CLiQ interface
5.3.4 X514 and X524 Power Supply
70
Sensor interface x520
5.3.6 X521 bidirectional digital inputs/outputs
522 digital inputs/ floating( isolated)……
72
3.8 Analog input X523…
5.3.9 Description of the LEDs on the Terminal Module TM41....................74
5.4
Dimension drawing........
75
55
Installation.…
B国面面B
.76
Electrical Connection
77
5.7
Commissioning
77
Additional SINAMICS System Components for SIMOTION
Manua,03/2007
Table of contents
58
Technical Specifications
国面B面
6 TermInal module tm54F
6.
Description
79
2
Safety Information
面B国
79
63
Interface description
6.3.1
6.3.2 Connection example
81
6.3.3 X500 and X501 DRIVE-CLiQ interface
82
634×514 Power supply…
·
82
6.3.5 X520 Sensor power supply
83
6.3.6 X521 Digital inputs dynamically adjustable power supply
637×522 Digital inputs
84
6.3.8 X523 Digital outputs
6.3.9 Electronics power supply X524
85
85
6.3.10 X525 Digital outputs
面面
6.3.11 X531 Digital inputs+ dynamically adjustable power supply
87
6.3.12 X532 Digital inputs
88
63.13×533 Digital outputs…
89
6.3. 14 X535 Digital outputs
6.3.15 Description of the Leds on the Terminal module tM54F
63.16 Cause and rectification of faults
91
6.4
Dimensional diagram
.92
6.5
Installation
93
6.6
Commissioning
94
6.7
Technical specifications
94
Communication Board CBE30
7.1
Description
95
7.2
Nameplates
Safety Information
97
Interface description
97
7.4.1 X1400 Ethernet interfaces
97
7.4.2 PROFINET cables
Q
7.4.3 LEd displays∴
100
7.5
Dimension drawing
.101
7.6
Installation/Mounting
102
Commissioning
102
7.8
Technical data
103
8 Controller extension cX32
看口m看■■■■
105
8.1
Description……
105
8.2
Safety Information
面面
,105
8
Interface description
1面面面面面
106
8.3.10
106
8.3.2 Connection example
107
8.3.3DRⅣ /E-CLiQ interface X100-×103.
108
Additional SINAMICS System Components for SIMOTION
Manua,03/2007
Table of contents
8.3.4 X122: Digital Inputs/Outputs
1画B
109
8.3.5 Electronics power supply X124
110
8.3.6 Description of the lEds on the cX32
110
8.4
Installation
111
8.5
Commissioning……
116
8.6
Technical Specifications
116
9 Terminal Board TB30 eEoBoRBooRaOURaeEeoooBoRoRmasRnesesoonDsoooapooosooomm 117
9
Description
117
9.2
Safety Information
9.3
Interface description
118
9.3.1
Overview
118
9.3.2 Connection example
119
9.3.3 X424 power supply digital outputs
120
9.3.4 Digital inputs/outputs X481
9.3.5 X482 analog inputs/outputs
122
9. 3.6 Working with analog inputs
122
9.4
Installation/Mounting
123
9.5
Electrical connection
124
9.6
Commissioning…
124
97
Technical Specifications
…125
A AppendⅨA
127
A.1
Spring-Loaded Terminals/Screw Terminals
1国国
127
A.2
EC Declaration of Conformity
128
Appendix B
,129
Drive computer performance
129
c ESD guidelines…
n131
C 1 Electrostatically sensitive modules
131
Electrostatic discharge from persons
132
Basic measures for protection against discharge of static electricity
133
Index
135
Tables
Table 1-1
Overview of additional SINAMICS system components
面B国面
15
Table 2-1
Interface overview of the tm15
23
Table 2-2
DRIVE-CLiQ interface X500 and X501
翻面国
26
Table 2-3
Terminals for the electronic power supply……
Table 2-4
Requirements for the electronic power supply.
27
Table 2-5
Screw termina×520
8
Table 2-6
Screw terminal x521
28
Additional SINAMICS System Components for SIMOTION
10
Manua,03/2007
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.