您好,欢迎光临本网站![请登录][注册会员]  
文件名称: 派特莱多层信号灯LS7 LED信号灯手册.pdf
  所属分类: 其它
  开发工具:
  文件大小: 7mb
  下载次数: 0
  上传时间: 2019-09-13
  提 供 者: weixin_********
 详细说明:派特莱多层信号灯LS7 LED信号灯手册pdf,派特莱多层信号灯LS7 LED信号灯手册。2 Model Number Configuration Model Tiers ated Body lighting Buzzer/Mounting Wiring Color Model no. LS7-:5: 02 -RYGBC Common to all models )5 LED Ti Common to a‖ models LED colors in order from top to common to all models)Rated Voltage: 24V DC bottom red, yellow, green blue and white. nell Off-white M12 Connector DArk Gray rer Illumination Buzzer not (Common o almds H Lead Wires" and flashi Direct Installation uz XF 'lumination and Flashing'function is Included only available for the h Lead wires specifications. Example LS7-502WC-RYGBC LS7-502SFBWH-RYGBC Body color… Off-white Buzzer…Not| ncluded Body color… Silver Buzzer…… Included Lighting..Illumination only M12 connector Lighting… Ilumination and flashing· Input… Lead wires 3 Part Names and Outer Appearance a Buzzer not included[C M12 connector specifications B Buzzer included H Lead wires specifications Outer cover Accessories Inner lens LED panel 244 Mount cover X1 O-ring Buzzer case Base Buzzer opening +9 Post-installation Relocation"(P. 21) O-ring X About the m12 connector optional connector with cable for M4 bolts(x 3) U wiring. d70 Lead wires(wire length: 1200) Because the m12 connector is to Waterproof packing allow a sufficient length of cable een from underneath en from underneat (For B Buzzer included (Note) The Signal Tower LED array is not replaceable (Units: mm)( specifications, the length is 55 mm. 15 4 Stackable Tower Construction LWhat is a Stackable Structure? The 'stackable structure' is a feature which allows the main signal tower unit and the outer cover to be separated with just a single touch (Previous signal towers require tools to disassemble, such as removing screws The' stackable structure' makes maintainance and inspection easier A CAUTION Never disassemble or remove any parts outside the stackable parts Procedure for removing the stackable parts Refer to the procedure below to remove the stackable parts To reinstall, follow the procedure in the reverse order (The following example is for a model without a buzzer included The removal procedure is the same as for the outer cover.) Unlocking Remove the base 14 Hold the base and the mount, and rotate until the bar Pull the base in the upward direction to remove it marks are aligned Tip Do not twist the base too hard when removing it The lock may be stiff When reinstalling, fully rotate the base until the triangle (Tip The signal tower is equipped with a buzzer case instead of mark and bar mark are aligned a base for the models equipped with the buzzer 5 Block Diagram The following illustrates the internal block diagram for the signal tower. Use it as reference when wiring LS7 Buzzer Circuit LED Circuit Flashing Circuit Flashing circuit s circuit Flashing Red LED (Note). The diagram illustrates flashing, Illuminating and specificatio The diagram is only an example iNstallation △ CAUTION The following requirements are The buzzer is unidirectional necessary for proper installation therefore it is most easily audible in the buzzer source direction Install the signal tower where Position the signal tower so that excessive vibration is not the buzzer diaphram is facing in the desired sound direction present (B Buzzer included specifications Install the signal tower on a sturdy surface Use a soft cloth etc, da with water to wipe the main signal tower unit Install the signal tower on a (Do not use cleaners containing level surface hemeicals such as thinner alcohol, gasoline or oil. Install the signal tower in an pright position X OX Thinner To ensure the waterproofing ×○ performance of this product, do not remove the o-ring or the wate General Installation 1「 Verify the signal tower installation position Marking holes for wiring and installation Punch. eto Installation Template P23) d on p.23 and a ch, etc to mark the places to make the holes following tips to check the following Will it obstruct other equipment? 3 Making the installation and wiring holes Can the wiring be routed properly le buzzer direction facing Drill . e Jse a drill, etc. to make holes for installation and wiring Continued on next I Remove the signal tower from the mount 6 Attach the main unit to the mount. Pull out the (H Lead wire specifications) Mount Main unit g Refer to“园4」 Stackable Tower Construction"(→P.16)for Thread the lead wires through the mount and wiring hole, details on how to remove the mount before installing the main unit to the mount Tip Place the mount in the installation holes r the c M12 connector option, thread the cable through the wiring hole and mount before connecting it to the main Refer to"4 Stackable Tower Construction"(P 16)for details on how to remove the mount Be careful not to pinch the lead wires or cable Adjust the sound to the desired level ( Refer to"图8 I Volume Adjustmen“"(→P.21) B Buzzer included specifications) Tighten the accessory nuts from Make sure to allow some slack for the lead wires or cable in the underside rder to adjust the volum (B Buzzer included specifications) Recommended Torque: 1.4 N-m Optional Installation Method If it is difficult to work on the underside by tightening Install with commercially-available screws the nuts when installing the mount use the spare installation holes Commercially-available Seen from underneath screws Installation the installation location Remove the existing bolts and nuts. M4 bolt Be sure to use screws long enough, keeping in mind the thickness of the mount, waterproof packing and mounting E Cross-section for the spare installation holes 9 Mount Nut F Waterproof packing (Contracts during tightening) (Units: mm 中4.2 18 7 Wiring △ WARNING Prior to wiring, ensure the power DC? Verify the power supply voltage supply is disconnected from the and whether it is direct current signal tower or alternating current △ CAUTION Never apply a voltage to the To protect the power supply and flashing common"wire other internal circuitry, be sure to Failure to observe will result in damage install an external fuse to the circuitry. F Ilumination and flashing specifications) Never connect the power × k supply wire to the"flashing common wire Do not pull on the lead wire Failure to observe will result in damage to the circuitry. (F Ilumination and flashing specifications When there are unused lead wires for the led tiers be sure to Do not push lead wires up into separately insulate the ends of each unused lead wire Do not connect the"flashing Buzzer)common"wire with the buzzer ( B Buzzer included specifications) Quick Tips If the leakage current from For models with the buzzer, if equipment, such as a PLC unit buzzer and buzzer are output, is 1mA or more, the triggered simultaneously, buzzer LEDs may show a dim 1 will take priority. (BBuzzer ilumination, but it is not the sign ncluded specifications of a problem ..0 Buzzer 1: Single continuous beep 0乙一 Buzzer2: Intermittent beeps The LEDs and the buzzers will When adding an additional length only operate when a signal of wire, use the appropriate wire nput is present lengths and wire diameters to (They do not operate on one-shot ensure there are no voltage signal pulses OFF Wiring Examples Wiring examples are shown in accordance to the signal tower model and external contact type If the signal tower is being used under special conditions and there are any questions, contact our PATLITE office prior to performing any wiring A CAUTION Do not connect unused lead wires to external contacts when unnecessary Insulate all unused lead wires with insulation tape, etc General wiring example M12 Connector Pin Layout Red LED Red/⑥ ※ B Buzzer included ②Bu DWhite LED pecifications only Name of PIN NO gReen LED Blue LED (Tip function (C M12 connector specifications) ⑨◎ IIt is recommended to or pin yEllow LED connector with cable for ayout" illustration to the right Lead wire color SoarEd wiring (H Lead wires specifications) ⑤ Power supply wire →“i4 ption Parts (P23) Product Illumination only pecifications Buzzer not included /B Buzzer included Model LS7-502□(B)W囗 External Contac Relay Contact External Contact PLC (PNP-type transistor) LS7 Transistor Symbol Output Unit LC Red LE Yellow LEDOrange/ 4 Green LED Green/3 Blue LEDBlue/⑦ Blue LED Biue I/ White LED White/ White LEDWhite/① Buzzer1Pwp/※ Power supply wire Yellow/⑤ supply wireYe|ow/⑤ Fuse 1A ※ B Buzzer included ※ BUzzer included ecifications only specifications only urination and flashing Buzzer included Model LS7-502□FBWH (Note)When using illuminating and flashing features together, it is necessary to have separate output units for the illuminating and flashing functons at the PLC side External Contact Relay Contact Type 7 15 External Contact PLC(PNP-type transistor Type 5 7 External contact i Do not apply voltage PLC Common flashing wire/Brown Red LEDRed Red LED Green LED Green Green Blue LED Blue Blue LEDB uminating White LED White White LED White I Buzzer Buzzer1Purplel Buzzer2Sky-bluel Buzzer 2Sky-bluel Power DC 24V I supply wire Yellow For illuminatin supply wire Yellow External contact Fuse 1A (No polarit 20 vOlume Adjustment The volume adjustment of the buzzer is done by inserting a screwdriver into the volume adjustmen Buzzer case Volume Adjustment Hole hole of the buzzer case Refer to“4 Stackable Tower Construction'(→P.16) for details on removing the buzzer case R/VOL Seen from Screwdriver O shipment from the factory ACAUTION Do not rotate the wolume any further than its specified range of movement when adjusting 9 Post-installation Relocation When installing the signal tower to equipment which is portable, observe the following when moving the equipment Detach the main unit from the mount. Install the optional mount cover. accessory Mount -Main unit Mount Disconnect the lead wires TRansport the equipment. Remove the main unit from the mount k fter relocating, remove the mount cover and reinstall Refer to"4 Stackable Tower Construction"(>P16)for the main unit in its original position reattaching the main unit to its original position For models with the C M12 connector, disconnect the Tip cable from the main unit Store the mount cover in a safe place after using it inSpection To ensure safe operation, it is recommended to perform the following on Repair Are all the LEds illuminated? Refer to the"11 Troubleshootingsection(P.22)if they do not illuminate Are all the buzzer functions sounding? or models equipped with the Buzzer Refer to the"11 Troubleshooting"section(>P. 22)if they do not sound function, only) Check the outside appearance. Is there any If there is any external damage such as cracks, or missing parts, stop using damage? the signal tower and replace the necessary parts or the main unit. (Refer to"13 Replacement Parts"(P. 23) 11 Troubleshooting If a problem occurs, check the following table to remedy the problem before calling for service Problem Where to Check Solution Refer to“【7 Wiring(→P.19) to double-check the Is the wiring properly connected? Iluminate Is the power supply at the correct voltage? Be sure to use a 24V DC power supply Is the fuse blown? If the fuse is blown, replace it Refer to“圖7 Wiring"(→P.19) to double- check the Is the wiring properly connected? wiring connection The buzzer does not Is the power supply at the correct voltage? Be sure to use a 24V DC power supply sound Is the fuse blown If the fuse is blown place it Double-check the product model Only signal towers with a b in the model type are equipped with a buzzer function Refer to"7 Wiring"(P. 19)to double-check the Is the wiring properly connected? The LEDs do not flash Double-check the product model Only signal towers with an F in the model type are equipped with a flashing function Refer to"4 Stackable Tower Con How is the outer cover and base(buzzer case) Only designated parts of the signal tower's (P 16)for proper assembly and dis-assembly stackable structure allows removable parts (Never disassemble or remove any parts other than removed? the stackable parts. (Note)The above describes the most common troubleshooting problems and possible solutions. To view more troubleshooting problems download the web version of the instruction manual from our company website If the problem is not corrected, even after the above remedies have been performed, use the table below to make detailed notes of the product, its problem, and then contact either the place of purchase or your nearest PATLITE Sales Representative ● The place of purchase● A PATLITE office(→ back cover Product Details Product name LED SIGNAL TOWER Purchase Date Model("2 Model Number Configuration"(P. 15)) Symptoms of Problem With as much detail as possible 12 Specifications Product specifications Rated Installation Power consumption Weight Buzzer Sound Inrush Flashing Wire.Wire voltage Location LED Buzzer Duration Pressure current frequency type diameter 2(None/D/S)W(C/H) -Approx320g 502(None/D/S)BWC DC 24V Indoor use only per tier 40mA Approx350g 520msec J Approx 5d8 150mA UL1007AWG22 lone/D/S)FBWH 60±12 times/min This product conforms to the RoHS directive(DIRECTIVE 2002/95/EC) This product complies with EN regulations and shows the CE symbol. (EN61000-6-4: 2007, EN61000-6-2: 2005) External Contact Specifications Contact-type relay(Switch 圖 PLC output unit oltage Rated Current Rated Voltage Rated Current oad LED Bu ED BuzzerCurrent DC24V 100 mA or more 200 mA DC24V 100 mA or more[ 200 mA 0.1 mA per leveler more per level or moreor less 22
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: