详细说明:派特莱多层信号灯LS7 LED信号灯手册pdf,派特莱多层信号灯LS7 LED信号灯手册。2 Model Number Configuration
Model Tiers ated Body lighting Buzzer/Mounting Wiring
Color
Model no. LS7-:5: 02
-RYGBC
Common to all models )5 LED Ti
Common to a‖ models
LED colors in order from top to
common to all models)Rated Voltage: 24V DC
bottom red, yellow, green
blue and white.
nell Off-white
M12 Connector
DArk Gray
rer
Illumination
Buzzer not (Common o almds H Lead Wires"
and flashi
Direct Installation
uz
XF 'lumination and Flashing'function is
Included
only available for the h Lead wires
specifications.
Example LS7-502WC-RYGBC
LS7-502SFBWH-RYGBC
Body color… Off-white
Buzzer…Not| ncluded
Body color… Silver
Buzzer…… Included
Lighting..Illumination only
M12 connector
Lighting… Ilumination and flashing· Input… Lead wires
3 Part Names and Outer Appearance
a Buzzer not included[C M12 connector specifications B Buzzer included H Lead wires specifications
Outer cover
Accessories
Inner lens
LED panel
244
Mount cover
X1
O-ring
Buzzer case
Base Buzzer opening
+9 Post-installation Relocation"(P. 21)
O-ring
X About the m12 connector
optional connector with cable for
M4 bolts(x 3)
U
wiring.
d70
Lead wires(wire length: 1200)
Because the m12 connector is
to
Waterproof packing
allow a sufficient length of cable
een from underneath
en from underneat
(For B Buzzer included
(Note) The Signal Tower LED array is not replaceable
(Units: mm)( specifications, the length is 55 mm.
15
4 Stackable Tower Construction
LWhat is a Stackable Structure?
The 'stackable structure' is a feature which allows the main signal
tower unit and the outer cover to be separated with just a single touch
(Previous signal towers require tools to disassemble, such as
removing screws
The' stackable structure' makes maintainance and inspection easier
A CAUTION Never disassemble or remove any parts outside the
stackable parts
Procedure for removing the stackable parts
Refer to the procedure below to remove the stackable parts
To reinstall, follow the procedure in the reverse order
(The following example is for a model without a buzzer included
The removal procedure is the same as for the outer cover.)
Unlocking
Remove the base
14
Hold the base and the mount, and rotate until the bar
Pull the base in the upward direction to remove it
marks are aligned
Tip
Do not twist the base too hard when removing it
The lock may be stiff
When reinstalling, fully rotate the base until the triangle
(Tip The signal tower is equipped with a buzzer case instead of
mark and bar mark are aligned
a base for the models equipped with the buzzer
5 Block Diagram
The following illustrates the internal block diagram for the signal tower. Use it as reference when wiring
LS7
Buzzer Circuit
LED Circuit
Flashing Circuit
Flashing circuit
s circuit
Flashing Red LED
(Note). The diagram illustrates flashing, Illuminating and specificatio
The diagram is only an example
iNstallation
△ CAUTION
The following requirements are
The buzzer is unidirectional
necessary for proper installation
therefore it is most easily audible
in the buzzer source direction
Install the signal tower where
Position the signal tower so that
excessive vibration is not
the buzzer diaphram is facing in
the desired sound direction
present
(B Buzzer included specifications
Install the signal tower on a
sturdy surface
Use a soft cloth etc, da
with water to wipe the main signal
tower unit
Install the signal tower on a
(Do not use cleaners containing
level surface
hemeicals such as thinner
alcohol, gasoline or oil.
Install the signal tower in an
pright position
X OX
Thinner
To ensure the waterproofing
×○
performance of this product,
do not remove the o-ring or
the wate
General Installation
1「
Verify the signal tower installation position
Marking holes for wiring and installation
Punch. eto
Installation Template
P23)
d on p.23 and a
ch, etc to mark the places to make the holes
following tips to check the following
Will it obstruct other equipment?
3 Making the installation and wiring holes
Can the wiring be routed properly
le buzzer direction facing
Drill . e
Jse a drill, etc. to make holes for installation and wiring
Continued on next
I Remove the signal tower from the mount
6 Attach the main unit to the mount.
Pull out the
(H Lead wire specifications)
Mount
Main unit
g
Refer to“园4」 Stackable Tower Construction"(→P.16)for
Thread the lead wires through the mount and wiring hole,
details on how to remove the mount
before installing the main unit to the mount
Tip
Place the mount in the installation holes
r the c M12 connector option, thread the cable through
the wiring hole and mount before connecting it to the main
Refer to"4 Stackable Tower Construction"(P 16)for
details on how to remove the mount
Be careful not to pinch the lead wires or cable
Adjust the sound to the desired level
( Refer to"图8 I Volume Adjustmen“"(→P.21)
B Buzzer included specifications)
Tighten the accessory nuts from
Make sure to allow some slack for the lead wires or cable in
the underside
rder to adjust the volum
(B Buzzer included specifications)
Recommended Torque: 1.4 N-m
Optional Installation Method
If it is difficult to work on the underside by tightening
Install with commercially-available screws
the nuts when installing the mount
use the spare installation holes
Commercially-available
Seen from underneath
screws
Installation
the installation location
Remove the existing bolts and nuts.
M4 bolt
Be sure to use screws long enough, keeping in mind the
thickness of the mount, waterproof packing and mounting
E Cross-section for the spare installation holes
9
Mount
Nut
F Waterproof packing
(Contracts during tightening)
(Units: mm
中4.2
18
7
Wiring
△ WARNING
Prior to wiring, ensure the power
DC?
Verify the power supply voltage
supply is disconnected from the
and whether it is direct current
signal tower
or alternating current
△ CAUTION
Never apply a voltage to the
To protect the power supply and
flashing common"wire
other internal circuitry, be sure to
Failure to observe will result in damage
install an external fuse
to the circuitry. F Ilumination
and flashing specifications)
Never connect the power
×
k supply wire to the"flashing
common wire
Do not pull on the lead wire
Failure to observe will result in damage
to the circuitry. (F Ilumination
and flashing specifications
When there are unused lead
wires for the led tiers be sure to
Do not push lead wires up into
separately insulate the ends of
each unused lead wire
Do not connect the"flashing
Buzzer)common"wire with the buzzer
( B Buzzer included
specifications)
Quick Tips
If the leakage current from
For models with the buzzer, if
equipment, such as a PLC unit
buzzer and buzzer are
output, is 1mA or more, the
triggered simultaneously, buzzer
LEDs may show a dim
1 will take priority. (BBuzzer
ilumination, but it is not the sign
ncluded specifications
of a problem
..0 Buzzer 1: Single continuous beep
0乙一 Buzzer2: Intermittent beeps
The LEDs and the buzzers will
When adding an additional length
only operate when a signal
of wire, use the appropriate wire
nput is present
lengths and wire diameters to
(They do not operate on one-shot
ensure there are no voltage
signal pulses
OFF
Wiring Examples
Wiring examples are shown in accordance to the signal tower model and external contact type
If the signal tower is being used under special conditions and there are any questions, contact our PATLITE
office prior to performing any wiring
A CAUTION Do not connect unused lead wires to external contacts when unnecessary
Insulate all unused lead wires with insulation tape, etc
General wiring example
M12 Connector Pin Layout
Red LED Red/⑥
※ B Buzzer included
②Bu
DWhite LED
pecifications only
Name of
PIN NO
gReen LED
Blue LED (Tip
function
(C M12 connector
specifications)
⑨◎
IIt is recommended to
or pin
yEllow LED
connector with cable for
ayout" illustration to the right
Lead wire color
SoarEd wiring
(H Lead wires specifications)
⑤ Power supply wire
→“i4 ption Parts
(P23)
Product
Illumination only
pecifications Buzzer not included /B Buzzer included
Model
LS7-502□(B)W囗
External Contac
Relay Contact
External Contact PLC (PNP-type transistor)
LS7
Transistor Symbol
Output Unit
LC
Red LE
Yellow LEDOrange/
4
Green LED Green/3
Blue LEDBlue/⑦
Blue LED Biue I/
White LED White/
White LEDWhite/①
Buzzer1Pwp/※
Power
supply wire Yellow/⑤
supply wireYe|ow/⑤
Fuse 1A
※ B Buzzer included
※ BUzzer included
ecifications only
specifications only
urination and flashing
Buzzer included
Model
LS7-502□FBWH
(Note)When using illuminating and flashing features together, it is necessary to have separate output units for the
illuminating and flashing functons at the PLC side
External Contact Relay Contact
Type 7 15
External Contact PLC(PNP-type transistor
Type 5 7
External contact
i Do not apply voltage
PLC
Common
flashing wire/Brown
Red LEDRed
Red LED
Green LED Green
Green
Blue LED Blue
Blue LEDB
uminating
White LED White
White LED White I
Buzzer
Buzzer1Purplel
Buzzer2Sky-bluel
Buzzer 2Sky-bluel
Power
DC 24V
I supply wire Yellow
For illuminatin
supply wire Yellow
External contact
Fuse 1A (No polarit
20
vOlume Adjustment
The volume adjustment of the buzzer is done by
inserting a screwdriver into the volume adjustmen
Buzzer case
Volume Adjustment Hole
hole of the buzzer case
Refer to“4 Stackable Tower Construction'(→P.16)
for details on removing the buzzer case
R/VOL
Seen from
Screwdriver O
shipment from the factory
ACAUTION Do not rotate the wolume any further than its
specified range of movement when adjusting
9 Post-installation Relocation
When installing the signal tower to equipment which is portable, observe the following when moving the
equipment
Detach the main unit from the mount.
Install the optional mount cover.
accessory
Mount
-Main unit
Mount
Disconnect the lead wires
TRansport the equipment.
Remove the main unit from the mount
k
fter relocating, remove the mount cover and reinstall
Refer to"4 Stackable Tower Construction"(>P16)for
the main unit in its original position
reattaching the main unit to its original position
For models with the C M12 connector, disconnect the
Tip
cable from the main unit
Store the mount cover in a safe place after using it
inSpection
To ensure safe operation, it is recommended to perform the following
on Repair
Are all the LEds illuminated?
Refer to the"11 Troubleshootingsection(P.22)if they do not illuminate
Are all the buzzer functions sounding?
or models equipped with the Buzzer
Refer to the"11 Troubleshooting"section(>P. 22)if they do not sound
function, only)
Check the outside appearance. Is there any
If there is any external damage such as cracks, or missing parts, stop using
damage?
the signal tower and replace the necessary parts or the main unit.
(Refer to"13 Replacement Parts"(P. 23)
11
Troubleshooting
If a problem occurs, check the following table to remedy the problem before calling for service
Problem
Where to Check
Solution
Refer to“【7 Wiring(→P.19) to double-check the
Is the wiring properly connected?
Iluminate
Is the power supply at the correct voltage?
Be sure to use a 24V DC power supply
Is the fuse blown?
If the fuse is blown, replace it
Refer to“圖7 Wiring"(→P.19) to double- check the
Is the wiring properly connected?
wiring connection
The buzzer does not
Is the power supply at the correct voltage?
Be sure to use a 24V DC power supply
sound
Is the fuse blown
If the fuse is blown
place it
Double-check the product model
Only signal towers with a b in the model type are
equipped with a buzzer function
Refer to"7 Wiring"(P. 19)to double-check the
Is the wiring properly connected?
The LEDs do not flash
Double-check the product model
Only signal towers with an F in the model type are
equipped with a flashing function
Refer to"4 Stackable Tower Con
How is the outer cover
and base(buzzer case) Only designated parts of the signal tower's
(P 16)for proper assembly and dis-assembly
stackable structure allows removable parts
(Never disassemble or remove any parts other than
removed?
the stackable parts.
(Note)The above describes the most common troubleshooting problems and possible solutions. To view more troubleshooting problems
download the web version of the instruction manual from our company website
If the problem is not corrected, even after the above remedies have been performed, use the table below to make detailed
notes of the product, its problem, and then contact either the place of purchase or your nearest PATLITE Sales Representative
● The place of purchase● A PATLITE office(→ back cover
Product Details
Product name
LED SIGNAL TOWER
Purchase Date
Model("2 Model Number Configuration"(P. 15)) Symptoms of Problem With as much detail as possible
12 Specifications
Product specifications
Rated Installation Power consumption Weight Buzzer Sound Inrush Flashing Wire.Wire
voltage Location LED Buzzer
Duration Pressure current frequency type diameter
2(None/D/S)W(C/H)
-Approx320g
502(None/D/S)BWC DC 24V
Indoor
use only per tier 40mA Approx350g 520msec J Approx 5d8 150mA
UL1007AWG22
lone/D/S)FBWH
60±12 times/min
This product conforms to the RoHS directive(DIRECTIVE 2002/95/EC)
This product complies with EN regulations and shows the CE symbol. (EN61000-6-4: 2007, EN61000-6-2: 2005)
External Contact Specifications
Contact-type relay(Switch
圖 PLC output unit
oltage
Rated Current
Rated Voltage Rated Current
oad
LED Bu
ED BuzzerCurrent
DC24V
100 mA or more 200 mA
DC24V
100 mA or more[ 200 mA 0.1 mA
per leveler more
per level or moreor less
22
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.