您好,欢迎光临本网站![请登录][注册会员]  
文件名称: RUGGEDCOM i801 Installation Guide[手册].pdf
  所属分类: 其它
  开发工具:
  文件大小: 1mb
  下载次数: 0
  上传时间: 2019-09-13
  提 供 者: weixin_********
 详细说明:RUGGEDCOM i801 Installation Guide[手册]pdf,RUGGEDCOM 1801 nstallation guide >>Contacting Siemens Address Telephone E-mail Siemens Canada ltd To|free:18882640006 ruggedcom.infoi-iasiemens.com Industry Sector Te:+19058565288 300 Applewood Crescen FaX:+19058561995 Web Concord, ontario www.siemens.com/ruggedcom Canada, l4K 5C7 RUGGEDCOM 1801 nstallation guide RUGGEDCOM 1801 nstallation guide Table of contents Table of contents Preface∴……,vi Alerts Related documents Accessing Documentation…… Training…………………… Customer Support VI Chapter 1 Introduction 1.1 Feature highlights 1.2 Description Chapter 2 stalling the Device… 2.1 General Procedure 2.2 Required Tools and materials 2.3 Mounting the Device .4 Connecting the Failsafe Alarm Relay(If Equipped 2.5 Connecting power 2.6 Connecting to the dey 2.7 Configuring the Device 2.8 inserting/ Removing the microSD/ Microsdhc card….….…,…,…,…,…,…,…,…,…,…11 Chapter 3 Communication ports . 3.1 Copper Ethernet Ports... 14 3.2 Fiber optic ethernet p。rt5… Chapter 4 Technica| Specifications∴…,,…,,…,,…, ·········.····· 17 4.1 Power Supply Specificati 4.2 Environmental Specifications 4.3 Failsafe Alarm Relay specifications 18 4.4 Copper Ethernet Port Specifications 4.5 Fiber Optic ethernet port specifications 18 4.6 Mechanica| Specifications……… Table of contents Installation guide Chapter 5 Dimension Drawings...........................21 Chapter 6 Certificatio 6.1 Approvals 23 6.1.1CSA 23 6.1.2ATEⅩ/ECEX 24 6.1.3 European Union(EU) 2 6.1.4 FCC 25 6.1.5 FDA/CDRH ···· 25 6.1.6|SED 25 6.1.7 ACMA 26 6.1. 8 ROHS 26 6.1.9|SO∴. ∴26 6.1.10 Other Approvals 27 6.2 EMC and Environmental Type Tests 27 RUGGEDCOM 1801 nstallation guide Preface Preface This guide describes the ruggedcom i801(i-Series) product line. It describes the major features, installation, commissioning and important technical specifications It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device. It is also recommended for use by network and system planners, system programmers, and line technicians CONTENTS ·" Alerts Related documents Accessing Documentation Training ·" Customer support Alerts The following types of alerts are used when necessary to highlight important information DANGER! DaNGER alerts describe imminently hazardous situations that, if not avoided, will result in death or serous InJury. △ WARNING! WARNING alerts describe hazardous situations that, if not avoided, may result in serious injury and/or equipment damage. △ CAUTION! CAUTiON alerts describe hazardous situations that, if not avoided, may result in equipment damage ① IMPORTANT IMPORTANT alerts provide important information that should be known before performing a procedure or step, or using a feature. i NOTE NOTE alerts provide additional information, such as facts, tips and details Alerts RUGGEDCOM I807 Preface Installation guide Related documents Other documents that may be of interest include: RUGGEDCOM ROS USer guide for the ruggedcom i80 1 Accessing Documentation ThelatestuserdocumentationforruggEdcomi801isavailableonlineatwww.siemens.com/ruggedcom.To request or inquire about a user document, contact Siemens Customer Support Training Siemens offers a wide range of educational services ranging from in-house training of standard courses on networking, Ethernet switches and routers, to on-site customized courses tailored to the customer's needs experience and application Siemens' Educational Services team thrives on providing our customers with the essential practical skills to make sure users have the right knowledge and expertise to understand the various technologies associated with critical communications network infrastructure technologies Siemens' unique mix of IT/Telecommunications expertise combined with domain knowledge in the utility transportation and industrial markets, allows Siemens to provide training specific to the customers application Formoreinformationabouttrainingservicesandcourseavailabilityvisitwww.siemens.com/ruggedcomor ontact a Siemens Sales representative Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods Online Visithttp://www.siemens.comlautomation/support-requesttosubmitaSupportRequest(sr)orcheckonthestatusofan existing Telephone CallalocalhotlinecentertosubmitaSupportRequest(sr).Tolocatealocalhotlinecentervisithttp:i/ www.automation.siemens.com/mcmslaspa-dblen/automation-technology/pagesidefault.aspx Mobile App Install the Industry Online Support app by Siemens AG on any Android, apple ios or Windows mobile device and be able to Access Siemens' extensive library of support documentation, including FAQs and manuals Subnit SRs or check on the status of an existing sr Contact a local Siemens representative from sales, Technical Support, Training, etc Ask questions or share knowledge with fellow Siemens customers and the support community Related documents RUGGEDCOM 1801 Chapter 1 nstallation guide Introduction Introduction The RUggedCom i801 is a compact, fully managed Ethernet switch designed to operate reliably in harsh industrial environments. The flexi bility of the ruggedcom i801 allows the user to choose from managed or unmanaged, regular or extended temperature, fiber optical or copper interfaces, and fast or gigabit Ethernet. With up to nine ethernet ports, the RUggedCom i801 is the perfect choice for a wide variety of demanding industria environments such as those found in process control applications (oil and gas, petro-chemical, metals and mining wind farms) The rUggedCom i801 is packaged in a compact, die cast aluminum, DIN mountable enclosure for efficient use of cabinet space. Dual 24 VDC power inputs increase reliability in case of primary power supply faults. The i800 provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found in industrial applications. An operating temperature range of -20 to 60C (4 to 140F)or optionally -40 to 85C (40 to 185F),coupled with hazardous location certification( Class 1 Division 2)allows the RUGGEDCOM i801 to be placed in almost any location The ruggedComi801 features a full array of intelligent functionality for high network availability and manageability. The embedded Rugged Operating System(RoS) provides advanced Layer 2 and Layer 3 networking functions, and advanced cyber security features. The Enhanced rapid spanning tree protocol(eRSt) provides very fast network recovery in case of failures, guaranteeing a high availability network and allows any topology from ring to mesh. Numerous other features like VLANs and Qos make the RUggedCOm i801 an enterprise class switch in an industrial class package CONTENTS Section 1.1,"Feature Highlights Section 1.2, " Description Section 1.1 Feature Highlights Ethernet ports Up to 8x 10/100Base-TX ports 1 1000Base-LX or 10/100/1000Base-TX port Industry standard lc fiber optical connectors Multi-mode and single-mode optical transceivers Cyber Security Features Multi-level user passwords SSH/SSL (128-bit encryption) Enable/disable ports, MAC based port security Port based network access control (802.1x) Feature Highlights Chapter 1 RUGGEDCOM I807 Introduction Installation guide VLAN (802.1Q)to segregate and secure network traffic RADIUS centralized password management SNMPV3 authentication and 56-bit encryption Rated for Reliability in Harsh Environments I mmunity to EMi and heavy electrical surges Hazardous location certification Class l Division 2 -20 to +60C (4 to 140F)operating temperature(optional -40 to +85C or-40 to 185 F) Conformal coated printed circuit boards(optional) Die cast aluminum enclosure Memory Options Removable microsdimicrosdhc card Power Supply Dual low-voltage DC inputs: 24 VDC (9-32 VDC) Compression fit connections CSA/UL 60950 safety approved to 85C(185F Section 1.2 Description The ruggedCom i801 features various ports, controls and indicator LEDs on the front panel for connecting configuring and troubleshooting the device U口 卫MMmu9 ●p 9 Figure 1: RUGGEDCOMi801 1. Failsate Alarm Relay 2. Power Supply Terminal Block 3. Chassis Ground Terminal 4. POWER LEDs 5. ALARM LED 6. Fiber Optic or Copper Gigabit Ethernet Port 7. Port Status LED 8. Copper Ethernet Ports 9. Access Plate 10 RS-232 Console Port(RJ-45) Failsafe Alarm Relay Latches to default state when a power disruption or other alarm condition occurs. For mare nformation refer to Section 2. 4, Connecting the Failsafe Alarm Relay(If Equipped) Section 4.3, Failsafe Alarm Relay Specifications Description
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: