Figure 1- Scratch-resistance test for protecting layers
Figure C. 1-Configuration of the test specimen
23
Figure C 2-Configuration of lands and adjacent conductors
24
Table 1- Minimum spacings for type 2 protection
.10
Table 2-Dry-heat conditioning .
14
Table 3-Degrees of severities for rapid change of temperature .............. 14
Table A. 1-Test sequence 1....................................................
Table A 2-Test sequence 2 additiona\ conditioning with respect to electromigration...18
19
Table A3-Additional tests
,19
4
EC60664-3:2016|EC2016
INT
TERNATIONAL ELECTROTECHNICAL COMMISSION
INSULATION COORDINATION FOR EQUIPMENT
WITHIN LOW-VOL TAGE SYSTEMS
Part 3: Use of coating, potting or moulding
for protection against pollution
FOREWORD
all national electrotechnical committees (EC National Committees ) The object of IEc is to promote
intarnational co-operation on all questions concerning standardization in the electrical and electronic fields. to
this end and in addit on to other activities, IEC publishes International Standards, Technical Specifications
Technical Reports, Publicly Available Specifications (PAS)and Guides hereafter referred to as lEC
Publication(s)"). Their preparation is entrusted to technical committees: any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. Internaticna, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates close y
with the International Organization for Standardization(Iso) in accordance with conditions determined br
agreement between the two organizations
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation trom all
nterested IEC National Committees
3) IEC Publications have the form of recommendations for international use and are accepted by IEC Naticnal
Committees in that sense. while all reasonable efforts are made to ensure that the technical content of lEc
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity r IEC Naticnal Committees undertake to apply IEc Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publicat on shall be clearly indicated in
the latter
5) IEC isel「de
「ical
assessment services and, in some areas, access to IEc marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
nembers of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other lEC
Publications
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publicat on
Attention is drawn to the rossibility that some of the e ements of this lEC Publication may be the subject o
atent rights. IEC shall not be held responsible for identi ying any or all such patent rights
International Standard IEC 60664-3 has been prepared by IEC technical committee TC 109
Insulation Co-ordination for low-voltage equipment.
It has the status of a basic safety publication in accordance with lEC Guide 104.
This third edition cancels and replaces the second edition published in 2003 and amendment
1: 2010. This edition constitutes a technical re vision
This edition includes the following significant technical changes with respect to the previous
edition
a) information added concerning interpolation
b) provided scratch test is only for lype 2 protection
EC60664-3:2016|EC2016
c)renumbered the scratch test to follow the visual examination test, since it makes more
sense there
d) separated the tables under what is now called Annex A, to make them clearer
The text of this standard is based on the following documents
FDIS
Report on voting
109/153FD|S
109/154/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table
This publication has been drafted in accordance with the iso/IEC Directives, Part 2
In this standard, the following types are used
Terms used throughout this standard which have been defined in Clause 3: bold type
A list of all parts in the IEC 60664 series, published under the general title insulation
coordination for equipment within low-voltage systems, can be found on the lEc website
The committee has decided that the contents of this publication will remain unchanged until
thestabilitydateindicatedontheiecwebsiteunderhttp://webstore.iecchinthedata
related to the specific publication. At this date, the publication will be
reconfirmed
withdrawn
replaced by a revised edition, or
amended
EC60664-3:2016|EC2016
INTRODUCTION
This part of Ec 60664 details the conditions in which the reduction of clearance and
creepage distances can apply to rigid assemblies such as printed boards or terminals of
components. Protection against pollution can be achieved by any kind of encapsulation such
as coating, potting or moulding. The protection may be applied to one or both sides of the
assembly. This standard specifies the insulating properties of the protecting material
Between any two unprotected conductive parts, the clearance and creepage distance
requirements of IEC 60664-1 apply
This document refers only to permanent protection. It does not cover assemblies after repa
Technical committees should consider the influence on the protection of overheating
conductors and components, especially under fault conditions, and to decide if any additional
requirements are necessary
Safe performance of assemblies is dependent upon a precise and controlled manufacturing
process for the application of the protective system. Requirements for quality control, e.g. by
sampling tests, should be considered by technical committees
EC60664-3:2016|EC2016
INSULATION COORDINATION FOR EQUIPMENT
WITHIN LOW-VOL TAGE SYSTEMS
Part 3: Use of coating, potting or moulding
for protection against pollution
sc。pe
This part of IEC 60664 applies to assemblies protected against pollution by the use of
coating, potting or moulding, thus allowing a reduction of clearance and creepage distances
as described in IEC 60664-1
This document describes the requirements and test procedures for two methods of
protection:
type 1 protection improves the microenvironment of the parts under the protection;
type 2 protection is considered to be similar to solid insulation
This document also applies to all kinds of protected printed boards, including the surface of
inner layers of multi-layer boards, substrates and similarly protected assemblies, In the case
of multi-layer printed boards, the distances through an inner layer are covered by the
requirements for solid insulation in IEC 60664-1
NOTE Examples of substrates are hybrid integrated circuits and thick-film technology
This document refers only to permanent protection. It does not cover assemblies that are
subjected to mechanical adjustment or repair
The principles of this standard are applicable to functional, basic, supplementary and
reinforced insulation
2 Normative references
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition
cited applies. For undated references, the latest edition of the referenced document(including
any amendments) applies.
lEC 60068-2-1, Environmental testing- Part 2-1: Tests- Test A: Cold
IEC 60068-2-2, Environmental testing- Part 2-2: Tests- Test B: Dry heat
lEC 60068-2-14, Environmental testing- Part 2-14: Tests- Test N: Change of temperature
lEC 60068-2-78, Environmental testing- Part 2-78: Tests Test Cab: Damp heat, steady
state
IEC 60326-2: 1990, Printed boards- Part 2: Test methods
lEC 60454-3-1: 1998/AMD1: 2001, Pressure-sensitive adhesive tapes for electrical purposes
Part 3: Specifications for individual materials- Sheet 1: Pvc film tapes with pressurE
sensitive adhesive
8
EC60664-3:2016|EC2016
lEC 60664-1: 2007, Insulation coordination for equipment within low-volfage systems- Part 1
Principles, requirements and tests
IEC 61189-2: 2006, Test methods for electrica/ materials, printed boards and other
interconnection structures and assemblies -Part 2: Test methods for materia/s for
interconnection structures
IEC 61189-3: 2007, Test methods for electrical materials, printed boards and other
interconnection structures and assemblies Part 3: Test methods for interconnection
structures(printed boards)
lEC 61249-2(all parts), Materials for printed boards and other interconnecting structures
Reinforced base materials, clad and unclad
lEC Guide 104: 2010, The preparation of safety publications and the use of basic safety
publications and group safety publications
I SO/EC Guide 51, Safety aspects- Guidelines for their inclusion in standards
3 Terms and definitions
For the purposes of this document, the terms and definitions given in lEC 60664-1 and the
following apply
ISo and IEC maintain terminological databases for use in standardization at the following
addresses
lecElectropedia:availableathttp://www.electropedia.org
soOnlinebrowsingplatformavailableathttp://www.isoorg/obp
3.1
base material
insulating material upon which a conductive pattern may be formed
Note 1 to entry: The base material may be rigid or f exible, or both. It may be a dielectric or an insulated metal
sheet
[ SOURCE:EC60050-541:1990,541-02-01]
3.2
printed board
base material cut to size containing all required holes and bearing at least one conductive
pattern
Printed boards are typically subdivided according to
their structure (e.g, single-and double-sided, multilayers)
the nature of the base material(e. g. rigid, flexible
[ SOURCE:EC60050-541:1990,541-01-03]
3.3
conductor (of a printed board) single conductive path in a conductive pattern
[ SOURCE:EC60050-541:1990,541-01-20]
EC60664-3:2016|EC2016
9
3.4
protection
measure which reduces the influence of the environment
3.5
coating
insulating material such as varnish or dry film laid on the surface of the assembl
Note 1 to entry: Coating and base material of a printed board form an insulating system that may have
properties similar to solid insulation
[ SOURCE:EC60050-2122010,212-11-61
solid insulation
solid insulating material, or a combination af solid insulating materials, placed between two
conductive parts or between a conductive part and a body part
EXAMPLE In the case of a printed board with a coating, solid insulation consists of the board
itself as well as the coating. In other cases, solid insulation consists of the encapsulating
materia
[ SOURCE:EC60050-903:2013,903-04-14]
3.7
spacing
any combination of clearances, creepage distances and insulation distances through
insulation
[ SOURCE:|EC60050471:2007,471-01-20]
4 Design requirements
4.1 Principles
The dimensioning of s pacings between conductors depends on the type of protection used
When type 1 protection is used, dimensioning of clearances and creepage distances shall
follow the requirements of IEC 60664-1. If the requirements of this standard are met, pollution
degree 1 applies under the protection
When type 2 protection is used, spacings between conductive parts shall meet the
requirements and tests for solid insulation of lEC 60664-1 and their dimensions shall not be
less than the minimum clearances specified in IEC 60664-1 for homogeneous field conditions
4.2 Application range with regards to the environment
The design requirements are applicable in all microenvironments
Stresses such as temperature, chemical or mechanical stresses, ar thase listed in 5.3.2. 4 of
lEC 60664-1: 2007 shall be taken into account when the protective material is selected
Absorption of humidity by the protective material shall not impair the insulation properties of
the parts being protected
NoTE Absorption of humidity can be checked by an insulation resistarce measurerment under humid conditions
-10
EC60664-3:2016|EC2016
4.3 Requirements for the ty pes of protection
Protection is achieved in the following ways
Type 1 protection improves the microenvironment of the parts under the protection. the
clearance and creepage distance requirements of IEc 60664-1 for pollution degree 1
apply under the protection. Between two conductive parts, it is a requirement that one or
both conductive parts, together with all the spacings between them, are covered by the
protection
Type 2 protection is considered to be similar to solid insulation. Under the protection
the requirements for solid insulation specified in Ec 60664-1 are applicable and the
spacings shall be not less than those specified in Table 1. The requirements for
clearances and creepage distances in IEC 60664-1 do not apply. Between two conductive
parts, it is a requirement that both conductive parts, together with all the spacings
between them, are covered by the protection so that no air gap exists between the
protective material, the conductive parts and the printed board
Clearance and creepage distance requirements according to IEC 60664-1 apply to all
unprotected parts of the equipment
4.4 Dimensioning procedures
For type 1 protection, the dimensioning requirements of 5. 1 and 5.2 of IEC 60664-1: 2007
apply.
For type 2 protection, the spacing between the conductors before the protection is applied
shall not be less than the values as specified in Table 1. These values apply to basic
insulation, supplementary insulation as well as reinforced insulation. These values may alsc
be applied to functional insulation
NOTE In case of multi-layer boards, the spacing between the conductors at the surface of inner layers is
dimens oned as speclfled for type 1 protection or type 2 protection depending on the result of the tests on the
protection
Table 1- Minimum spacings for type 2 protection
Maximum peak value of any voltage a
Minimum spacings
≤0,33
0,01
>0,33and≤0,4
0.02
>0,4and≤0,5
0.04
>0,5and≤0,6
0.06
>0,6and≤0,8
>0,8and≤1,0
0,15
1,0and≤1,2
0,2
1,2and≤1,5
0,3
1,5and≤2,0
0,45
>2,0and≤2,5
0,6
2,5and≤3,0
0.8
3,0and≤4,0
1.2
>4,0and≤5.0
1,5
50and≤6,0
2
>6,0ard≤8,0
3
8,0and≤10
3,5
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.