您好,欢迎光临本网站![请登录][注册会员]  
文件名称: UCATestProceduresServer61850-8-1_Rev3p3.pdf
  所属分类: 网络基础
  开发工具:
  文件大小: 1mb
  下载次数: 0
  上传时间: 2019-08-17
  提 供 者: firef*****
 详细说明:UCA官方的IEC61850Ed1Server测试用例,版本为3.3,2019最新版本539-MOC/INC 11-Rey33 Revision Changed test procedures Affected test procedures Rev 3.0 Combined edl test procedures version 2.3 with TPCL 1.8 8-Aug-2015 Initial release to UCAlug Rev 3.01 ctions due to olete Rpls, br3, CtIn6 Corrections due to incomplete merger of the two documents 15- Add detailed test case from TPCL l 8 Br3 comment-Copy from TPCL 1.8 CtIN6-not copied from TP 2.3 Table A.4.2-Conditional upon Ct9 o A4.10- Add detailed test case o Certificate: Conditional for 12c and 12d Rey 3. 02 Modify CtIN8 to match clarifications from TPCL 1.7.4 item 35 CtIN8, Md17, Srv12 (∴…. after50% of the operate timeout.” removed Removed tissue #38 and #58. added #1199 from MdI7 Rev 3.03 Remove Rp15, Br15(should only have been in Ed2 server test- RpN4/ BrN4 g RpN5/ BrNS Rp2 and Rp3 editorial change rpn&/ Brn8 Removed the non-applicable reporting error codes rpN, brN4 RpN5, BrN5, RpN8, BrN8 Br26 Modified certificate template: Rpg in conditional column should have becn rp?(crror from original TP 3.0) Added pixit entries ct23 and Ct24 and ct25 Rey 3. 04 Editorial changes Added srv12 Rev 3.1 Editorial changes Srv5, Srv12, Rpll Rey 3.2 Removed step 1 from Srv5 Srvs Srv12 removed the quality part from expected result Srv12 Updated the goose pixit references in the test procedures Ct13 scle has no addcau Ctl3 Updated PIXit template to rev9 Comments Sarah, e-mail dd. 22 January Srv 12, rp3/ Br3 Telco 23Jan2018- Perform Test at Select With value is not CtIN10. CtIN11 mandatory Updated some PIXit references Updated"intermediate-state'(when supported) SBOes3 does 5 Update PiXit to version/e tests Remove redundant addcauso Ctn PIXIT template Rey 3.3 I Remove TISSUE #780 behavior from Rp 3. Br3 and Log4 (only Rp 3. Br3 Log4 supported trigger conditions) Fixed PIXIT references in Ctl3, rp 2, br2, Tm3 Ct13, Rp2, Br2, Tm3 Clarified step 8 cted result in br2 8 Br28 Changed PiXit rcference Tm6 to Tm7 in table A.4.2 Fixed reference in br25 abstract test cases Added PIXIT Lg5 to specify supported Log opt Flds Log4 539-MOC/INC 11-Rev3 3 CONTENTS Introduction Identifications 6 Backs d 7 L.3 Purpose of this document 7 Contents of this do 7 Glossary 8 2.1 ormative 2.2 Other∴ 10 The Conformance test.…… Components in the test environment 3.2 Overview of the test suite LI 12 Conclusions and re 14 Annex A-Detailed Test procedures 15 A4 Application A4.2 Server logical Device logical Node data 30 A4.3 Data set 42 Substitution ……9 A4.5 Setting group control… .63 A4.6 Unbuffered Reporting 70 A4.7 Buffered Reporting . A4.8b Logging.… l10 A4.9 Generic Object Oriented Substation Events(GOOSE) 117 A4.10 Control.… ········ 132 A410a Control dons 144 A4 10b Control sbons 146 A410c Control does 149 A410d Control soes .151 A41I Time and time synchronization 157 File transfer 160 A4.13 Combinations& free form testing.......……… 164 Annex B Detailed description of test results 165 PICS Template… ······;:·:;·· .··············· 166 MICS Template 175 TICS Template 81 PIXIT Template 185 PIXIT for Documentation …186 PIXIT for association model 186 PIXIT for Server model 187 539-MOC/INC 11-Rev3 3 PIXIT for Data set model .......................................................................188 PIXIT for Substitution mod 189 PIXIT for Setting group control model 189 PIXIT for Reporting model..,.,.,.,,…,……………,190 P| XIT for Logging mode......,………,191 PIXIT for GoOSE publish model 192 PIXIT for Goose subscribe model 193 PIXIT for GOOSE performance 194 PIXIT for Control model ······ 194 PIXIT for Time synchronisation model PIXIT for file transfer model PIXIT Revision History ……201 Certificate template.... 539-MOC/INC 11-Rev3 3 Introduction Identifications The following table gives the exact identification of tested equipment and test environment used for this con formance test DUT MANUFACTURER PICS MICS TICS PlAIT < -complete reference description of the PIXIT> IcD complete reference description of the ICd configuration file> ScD complete reference description of the SCD or CID configuration file> TEST INITIATOR TEST SESSION SIMULATOR ANALYSER EQUIPMENT SIMULA- TOR TIME MASTER NOTE; the TEST FACILITY or MANUFACTURER can provide the documents in digital or printed format 539-MOC/INC 11-Rev3 3 1.2 Background The TEST FACILITY'S assignment was to answer the following question Does the protocol impiementation of the Dut, conform to the IEC 61850 standard and the pIcS, MCS, PLXTT and /CD specifica tions as configured with SCD? To answer this question, TEST FACILITY has performed a conformance test of the IEC 61850 implementation in the DUT. This test has been performed according procedures and conditions set forth in IEC 61850 part 10 and UCA IUG Quality Assurance Program TEST FACILITY is accredited/ recognized by the uca lug to perform formal uca conformance tests and issue the level a/b uca certificate Purpose of this document The purpose of this document is to describe the conformance test procedure and results of the test SESSION concerning the IeC 61850 implementation in the Dut. The test results are the basis of the conformance statement 14 Contents of this document Chapter 2 shows the list of relevant normative and other references, used to provide input for the conformance test Chapter 3 describes the various relevant components for the conformance test and their configura- tion as used in the conformance test, including the dUt. this chapter also gives an overview and introduction to the various test groups that together constitute the conformance test Chapter 4 and 5 give an overview and summary of the test results, the conclusion(s) and recom mendations Annex A specifies the detailed test procedures and their outcome. Annex B contains detailed com ments on test results, for instance when a defect is detected, including the actual message flow if appropriate. Annex C provides a template for tiCs documents. This template also specifies the mandatory technical issues. Annex D and e provide templates for the pixit document and uCa IEC 61850 Server certificate 539-MOC/INC 11-Rev3 3 osSary DUT Device Under Test ICD IED configuration description in SCL-format MICS Model implementation Conformance Statement PICS Protocol Implementation Conformance Statement TICS Technical Issues Implementation Conformance Statement PIXIT Protocol Implementation eXtra Information for testin SCD Substation configuration description in SCl-format SCL Substation Configuration Language SNTP Simple network Time Protocol TISSUE Technical issue TPAA Two-Party Application Association(Client-Server relationship) UCAIUG UCA International Users Group REFERENCES Normative The tests defined in this document are based on the following eC 61850 documents: IEC/TR 61850-1, Communication networks and systems in substations-Part I Introduction and overview: first edition 2003-04 IEC/TS 61850-2, Communication networks and systems in substations- Part 2: Glossary First edition 2003-08 IEC 61850-3, Communication networks and systems in substations-Part 3: General require ments first edition 2003-01 IEC 61850-4, Communication networks and systems in substations -Part 4: System and pro- ject management; First edition 2003-01 IEC 61850-5, Communication networks and systems in substations- Part 5: Communication requirements for functions and device models; First edition 2003-07 IEC 61850-6, Communication networks and systems in substations-Part 6: Substation auto mation System configuration language, first edition 2004-03 IEC 61850-7-1, Communication networks and systems in substations -Part 7-1: Basic com- munication structure for substation and feeder equipment- Principles and models; First edi- tion2003-07 IEC 61850-7-2, Communication networks and systems in substations-Part 7-2: Basic com- munication structure for substation and feeder equipment- Abstract communication service interface(ACSD; First edition 2003-05 539-MOC/INC 11-Rev3 3 IEC 61850-7-3, Communication networks and systems in substations Part 7-3: Basic com munication structure for substation and feeder equipment- Common data classes and attrib- utes: First edition 2003-05 IEC 61850-7-4, Communication networks and systems in substations-Part 7-4: Basic com munication structure for substation and feeder equipment Compatible logical node and data object addressing; First edition 2003-05 IeC 61850-8-1, Communication networkS and systems in substations -Part 8-1: Specific communication service mapping(SCSM)-Mappings to MMs (ISO/EC 9506-l and ISO/IEC 9506-2)and to ISO/IEC 8802-3: First edition 2004-05 IEC 61850-10, Communication networks and systems in substations- Part 10: Conformance testing; First edition 2005-05 -10 539-MOC/INC 11-Rev3 3 2.2 Other Is 9646-OSI-Conformance testing methodology and framework UCA International User Group: Conformance Test Procedures for Server Devices with IEC 61850-8-1 Interface Revision 3. 03 November 2015 Protocol Information eXtra Information for Testing, template extracted from Server Test Pro- cedures for Edition 2, date April 21, 2013 UCA International User Group: Quality Assurance Program Addendum for IEC 61850 Spe cific Product Testing, Version 1.0, March 8, 2006 .http://tissues.iec61850.com/
(系统自动生成,下载前可以参看下载内容)

下载文件列表

相关说明

  • 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
  • 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度
  • 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
  • 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
  • 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
  • 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.
 输入关键字,在本站1000多万海量源码库中尽情搜索: