详细说明:Road vehicles — Environmental conditions and testing for electrical and electronic equipment —
Part 2:Electrical loadslsO16750-2:2010(E)
Contents
Page
Foreword
cope
Normative references
Terms and definitions
Tests and requirements
General
∴1
4.2 Direct current supply voltage..
2
4.3
Overvoltage……,…
■■■■重D日国■■1道面
3
4.4 Superimposed alternating voltage
5 Slow decrease and increase of supply voltage
6
4.6 Discontinuities in supply voltage
6
4.7
Reversed voltage
48 Ground reference and supply offset……
15
4. 9 Open circuit tests
15
4.10 Short circuit protection.
16
4.11 Withstand voltage.
17
4.12 nsulation resistance
18
4.13 Electromagnetic compatibility.......
18
Documentation
18
Bibliography
19
O Iso 2010-All rights reserved
so16750-2:2010(E)
Foreword
ISo (the International Organization for Standardization)is a worldwide federation of national standards bodies
(Iso member bodies ). The work of preparing International Standards is normally carried out through ISo
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with Iso, also take part in the work. Iso collaborates closely with the
International Electrotechnical Commission(IEC)on all matters of electrotechnical standardization
International Standards are drafted in accordance with the rules given in the isonEC Directives Part 2
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 of the member bodies casting a vote
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. Iso shall not be held responsible for identifying any or all such patent rights
so 16750-2 was prepared by Technical Committee ISo/TC 22, Road vehicles, Subcommittee SC 3
Electrical and electronic equipment
This third edition cancels and replaces the second edition(Iso 16750-2: 2006), which has been technically
revised
Iso 16750 consists of the following parts, under the general title Road vehicles- Environmental conditions
and testing for electrical and electronic equipment
Part 1: General
- Part 2. Electrical loads
Part 3: Mechanical loads
Part 4: Climatic oads
Part 5: Chemical loads
O Iso 2010-All rights reserved
INTERNATIONAL STANDARD
so16750-2:2010(E
Road vehicles-Environmental conditions and testing
for electrical and electronic equipment
Part 2
Electrical loads
1 Scope
This part of iso 16750 applies to electric and electronic systems/components for road vehicles. This part of
ISo 16750 describes the potential environmental stresses and specifies tests and requirements
recommended for the specific mounting location on/in the road vehicle
This part of Iso 16750 describes the electrical loads. Electromagnetic compatibility(EMC)is not covered by
this part of Iso 16750. Electrical loads are independent from the mounting location, but can vary due to the
electrical resistance in the vehicle wiring harness and connection system
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document(including any amendments) applies
so 8820(all parts), Road vehicles- Fuse-links
ISo 16750-1, Road vehicles Environmental conditions and testing for electrical and electronic
equipment-Part 1: Genera
ISo 16750-4. Road vehicles
Environmental conditions and testing for electrical and electronic
equipment-Part 4. Climatic loads
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISo 16750-1 apply
4 Tests and requirements
4.1 Genera
If not otherwise specified, the following tolerances shall apply
frequency and time: +5 %;
voltages:±0,2V;
resistance:±10%
Iso 2010-All rights reserved
so16750-2:2010(E)
If not otherwise specified, measure all voltages at the relevant terminals of the device under test (DUT)
4.2 Direct current supply voltage
4.2.1 Purpose
The purpose of this test is to verify equipment functiona lity at minimum and maximum supply voltage
4.2.2 Test method
Set the supply voltage as specified in Table 1 or Table 2 to all relevant inputs of the DUT. Operating modes
are specified in ISo 16750-1
The voltages listed in Table 1 or Table 2 are relevant within the operating temperature range as specified in
ISO 16750-4. without time limits
Table 1- Supply voltage for system devices with 12 V nominal voltage
Minimum supply voltage Maximum supply voltage
Smax
A
6
16
B
8
16
C
10,5
16
Table 2- Supply voltage for system devices with 24 V nominal voltage
Minimum supply voltage Maximum supply voltage
Code
V
E
10
32
F
16
32
H
18
32
4.2.3 Requirement
All dUT functions shall remain class A as defined in Iso 16750-1 when tested in the supply voltage ranges
given in Table 1 or Table 2 respectively
O Iso 2010-All rights reserved
lsO16750-2:2010(E)
4.3 Overvoltage
4.3.1 Systems with 12 V nominal voltage
4.3.1.1 Test at a temperature of Imax-20C
4.3.1.1.1 Purpos
This test simulates the condition where the generator regulator fails, so that the output voltage of the
generator rises above normal values
4.3.1.1.2 Test method
Heat the DUT in a hot air oven to a temperature that is 20C below the maximum operating temperature
Tmax. Apply a voltage of 18 V for 60 min to all relevant inputs of the DUT
4.3.1.1.3 Requirement
The functional status for the dut shall be minimum class c as defined in so 16750-. functional status shall
be class a where more stringent requirements are necessary
4.3.1.2 Test at room temperature
4.3.1.2.1 Purpose
This test simulates a jump start
4.3. 1.2.2 Test method
Ensure that the dut has stabilized at room temperature. Apply a voltage of 24v for(60+6s to all relevant
inputs of the DUT
4.3.1.2.3 Requirement
The functional status shall be minimum class d as defined in iso 16750-1. functional status shall be class c
where more stringent requirements are necessary.
4.3.2 Systems with 24V nominal voltage
4.3.2.1 Purpose
This test simulates the condition where the generator regulator fails, so that the output voltage of the
generator rises above normal values
4. 3.2.2 Test at a temperature of Imax -20C
Heat the dUT in a hot air oven to a temperature that is 20c below the maximum operating temperature
max. Apply a voltage of 36 V for 60 min to all relevant inputs of the dUt
4.3.2.3 Requirement
The functional status shall be minimum class c as defined in iso 16750-. functional status shall be class a
where more stringent requirements are necessary
Iso 2010-All rights reserved
so16750-2:2010(E)
4.4 Superimposed alternating voltage
4.4.1 Purpose
This test simulates a residual alternating current on the direct current supply
4, 4.2 Test method
Connect the DUT as shown in Figure 1. Apply the following test simultaneously to all applicable inputs
(connections )of the DUT; the severity level(1, 2, 3 or 4)shall be chosen in accordance with the application
maximum supply voltage, USmaxsee Figure 2)
16V for systems with nominal voltage, UN, of 12V
32V for systems with nominal voltage, UN, of 24 V;
a.c. voltage(sinusoidal
severity 1: peak to peak voltage, Upp, of 1 V, for UN=12 V and UN=24 V
severity 2: peak to peak voltage, Upp, of 4 V, for UN-12V and UN=24 V;
severity 3: peak to peak voltage, Upp, of 10 V, for UN=24 V only
severity 4: peak to peak voltage, Upp, of 2 V, for UN=12 V
internal resistance of the power supply: 50 mQ2 to 100 mQ2
frequency range(see Figure 3 ): 50 Hz to 25 kHz
type of frequency sweep(see Figure 3): triangular, logarithmic,
sweep duration(see Figure 3):120 s
number of sweeps: 5(continuously)
4
5
sweep generator
2 power supply unit capable of being modulated
DUT
4 positive
5 ground or return
Figure 1-Test set-up to superimpose a.c. voltage on component power supply lines
O Iso 2010-All rights reserved
lsO16750-2:2010(E)
Smax
time
test voltage
peak to peak voltage
Smax
maximum supply voltage
Figure 2- Test voltage with superimposed sinusoidal a.C. voltage
25000
50
0
60
120t
Key
t time in seconds
f frequency, logarithmic scale, in hertz
one cycle
Figure 3- Frequency sweep
Iso 2010-All rights reserved
so16750-2:2010(E)
4.4.3 Requirement
The functional status shall be class a as defined in iso 16750-1
4.5 Slow decrease and increase of supply voltage
4.5.1 Purpose
This test simulates a gradual discharge and recharge of the batter
4.5.2 Test method
Apply the following test simultaneously to all applicable inputs(connections)of the dUt
Decrease the supply voltage from the minimum supply voltage, USmin, to o V, then increase it from o V to
iSmin, applying a change rate of (0, 5+0, 1)V/min linear, or in equal steps of not more than 25 mV
4.5.3 Requirement
The functional status inside the supply voltage range(see Table 1 or table 2 )shall be as specified in 4.2.3
Outside that range, it shall be minimum class d as defined in iso 16750-1. the functional status of class c
may be specified where more stringent requirements are necessary
4.6 Discontinuities in supply voltage
4.6.1 Momentary drop in supply voltage
4.6.1.1 Purpose
This test simulates the effect when a conventional fuse element melts in another circuit
4.6.12 Test method
Apply the test pulse (see Figures 4 and 5) simultaneously to all relevant inputs(connections)of the dUT. the
rise time and fall time shall be not more than 10 ms
U
4.5
10
10,1
K
time. in seconds
test voltage in volts
Usmin minimum supply voltage
Figure 4- short voltage drop for systems with 12 V nominal voltage
O Iso 2010-All rights reserved
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.