详细说明:The NI CB-2162 is a connector block and prototyping board for National Instruments digital
waveform generator/analyzer modules. The NI CB-2162 provides an easy way to complete the
following tasks:
• Terminate digital I/O (DIO) and control channels
• Connect to other devices for testing and debugging
• Develop and interface to prototype circuits
• Probe DIO and control channels
This guide explains how to set up and use the NI CB-2162 single-ended DIO accessory.Parts Locator Diagram
Refer to Figure I to locate connectors and components on the NI CB-2162
igure 1. NI CB-2162 Parts Locator Diagram
W/4------,
-4686885
中 00000o。 oO D00000。o。!。o。o。oco。 0C0000OO
O
兮今心骨心中业它
o|。od。 a clolololololololo
P-Ta_ 19 CLKgUT SFRCBI
N
OOaCooQ
OOOOOOoC
oOaC0ooo
NATONAL
INSTRUMEN
OOOOOOOC O
0aCO0Oo G
。 CNooc
189。。。NICB/SCB-2162。。。。°
ooacooc。
SINGLE-ENDE
OOCCoooo D[GITAL I/C ACCESSORY
。 Cnooc
FOR PATENTS: N COM/PATENTS
68-Pin Digital Data Control(DDC)Connector 6 Prototyping Area Power and Ground Solder Pads
2 Termination Sockets
7 Prototyping Area
3 Control and ground Header pairs
8 Labeling Strips
4 Prototyping Area Power Connectors
9 DIO and Ground Header Pairs
5 Prototyping Area Power LED
NI CB-2162 User Guide C National Instruments 3
Installing Cables
A cable connects the ni CB-2162 to the digital waveform generator/analyzer. Figure 2 shows
how to install a cable
Figure 2. Connecting a 68-Pin Digital Waveform Generator/Analyzer to the CB-2162
NIPX|-1042
的「1
①M电
B8A◆,。画
1 PXI Chassis with NI Digital Waveform
2 Cable
GeneratorAnalyze
3 NI CB-2162 Accessory
Refer to Figure 2 as you complete the following steps to install the supported cable
Caution
connecting the cable, disconnect powcr from thc module,
accessory, and any other connected hardware to prevent damage to the hardware and
personal injury. NI is liable for damage resulting from improper connections
1. Install Nl-HSDIO or NI-DAQmx and the digital waveform generator/analyzer by
following the installation procedure in the Getting Started Guide that shipped with your
device
Caution
attaching any cables or accessories, install the digital waveform
r/analyzer. refer to the getting Started Guide that shipped with your de
for instructions on installing the module
generator/analyzer module and secure the cable with the captive screws on the cabc B
2. Attach either end of the cable assembly to the ddc connector of the digital wavefo
connecto
3. Attach the other end of the cable assembly to the ddc connector of the ni cB-2162 and
sccurc thcm togcthcr with the captive screws on the cable connector
4ni.comiNicB-2162UserGuide
Connecting Signals
Each DIO, PFI, and clock channel of the digital waveform generator/analyzer connects to a
corresponding pin on the Ni CB-2162
Refer to Figure I for the location of these pins on the NI CB-2162
△
Caution
rcmovc powcr
& a bowering down the digital waveform generator/analyzer module,
the prototyping arca of the NI CB-2162 NI is liable for any
damage resulting from improper signal connections
Figure 3 shows the ddC connector pinout of the NI CB-2162
Figure 3. NI CB-2162 DDC Connector Pinout
D|o31
35DIO
GND 2 GND
D|O29337Do28
GND
Do27539D|o26
GND
40 GND
41Do24
RESERVED842 GND
D|O23943Do22
Do211145D020
GND1246GND
Do191347D018
GND14 48 GND
D|o171549D|o16
GND GND
D|O151751Do14
GND 52 RESERVED/PFL_O
D|O131953DO12
GND 20 54 GND
D|O112155Do10
Do92357Do8
GND 2458 GND
DO72559D06
PFI12660RESERVED
D|o52761Do4
GNDGND
D|O3|2963Do2
PF|33064PF|2
D|O13165Do0
GND GND
DDC CLK OUT/PFL_4 STROBE/PFL_5
GND GND
NI CB-2162 User Guide C National Instruments5
Note Refer to the help file for your device for information about the number of
available DIo channels on your device. DIO <20.31> or PFI 0 may not be
licable to your device The function of ddC clK out/PFi 4 and
STROBE/PFI 5 may bc unique to your devicc
Table l describes the DDC signals shown in Figure 3
Table 1. DDC Connector Pinout descriptions
DDC Pin
Signal Description
DIO<0.31>
Bidirectional digital data channels 0 through 3 1
STROBE/PFI 5
External sample clock source for pattern acquisition or
gcncral-purposc PFI
DDC CLK OUT/PFI 4 Exported sample clock signal or general-purpose PFI
PFI<0.3>
Programmable functional interface(PFD)channels 0 through 3
GND
Ground reference for signals
RESERVED
These channels are reserved for system use. Do not connect
signals to these channels
Refer to your device documentation for support
The NI CB-21 62 provides connectivity to up to 32 of the single-ended DIO channels of an NI
digital waveform generator/analyzer. The 32 diO channels are divided into two bundles of
16 2 header pins. Each bundle is
d by signal and ground pairs the
ground return paths for the dio channels
You can makc connections to the dio channcls thc pfi channcls, DDC CLK oUT/PFI 4 or
STROBE/PFI 5 on the ni CB-2162 using a l x 2 header receptacle, ribbon cable, a wire-wrap
technique or by soldering directly to the pins. Examples of how to make these connections are
p
wing sections
tions that exceed
fthe m
m ratings for the ni cB-2162
or the ni digital waveform generator analyzer module can damage the module and
Iter. ma
out ratings are provided in th
nd
in the specifications document that shipped with the digital waveform
analyzer. NI is liable for any damage resulting from such signal
connections
6ni.comNiCb-2162UserGuide
Using 1 x 2 Header Receptacles
Each signal and ground header pair is labeled on the Ni CB-2162 and in Figure 1. These header
pairs are arranged so that you can make quick connections using a l x 2 header receptacle to a
coaxial cable assemblv
Note Header receptacle assemblies are not included with the ni cB-2162, but you
can create custom assemblies by purchasing parts from vendors such as 3M
receptacle documentation to assure that proper connections are made to signal and ground o
Connectivity is made by inserting the receptacle onto the appropriate header pair. Refer to the
Figure 4 shows how to make 1 x 2 header receptacle connections
Figure 4. 1 x 2 Header Receptacle
11×2 Header Receptacle
2 Header pin pair
NI CB-2162 User Guide C National Instruments 7
Using a ribbon cable
The header pairs on the ni cB-2162 are available for single wire probing. You also can use
lbbon cables to easily connect a lar
mber of channels to other devices. Cable ty
and quality can dramatically affect how well the signal integrity is maintained. N recommends
using short twisted
Refer to the device or cable manufacturer for additional information on proper connectivity to
the ni CB-2162 signal and ground connections
Figure 5 shows how to connect a ribbon cable to the accessory
Figure 5. Using a Ribbon Cable with the NI CB-2162
TERMINAT. ON
OOOOOO
odalalololoololololololo
小自个,节争听321 CLKOUT数RoBE
△
0o0ooooo
ooo。oooo
9。 ooooooo
oooooooo
ATONAL
TRUMENIS8 00000000 oo
32688 NI CB/SCB-21628889cm
SINGLE-ENDED
。 ooooooo
DIGITAL I/O ACCESSORY
ooo。oo
"。△
o口
ROCS/N
ASsY188290C-01
FOR PATENTS; NI. COM/PATENTS
POWER
8 ni. com NI CB-2162 User Guide
Making a Wire-Wrap Connection
Make connections from the appropriate 1 x 1 header with a standard wire-wrap tool and
30-gauge or similar wire. Strip the wire and insert it into the receptacle end ofthe wire-wrap tool
Place the wire-wrap tool over the appropriate header pair pin, and twist the tool around the
header post. You then can make connections to the device under test(dUT)as defined by the
device manufacturer. Connect the DIO channel and ground header pins for each channel being
used
Figure 6 provides an illustration for making a wire-wrap connection
Figure 6. Wire-Wrap Connections
1 Wire-Wrap Tool
3 Header Pin Receptacle
2 Stripped Wire
Terminating Signals
Termination of high-speed digital signals is necessary to prevent signal reflections and to force
signal channels to a known state when no signal is present. Sockets for terminating resistors are
connected to all dio and control channels on the ni cB-2162. These sockets are labeled in
Figure 1
Note Proper termination needs are application-specific. For some special
considerations for choosing resistor values, refer to the
NI CB-2162 User Guide C National Instruments9
Minimizing the effects of stubs
Stubs are unterminated tributaries from the original signal path. Stubs decrease the signal quality
of the system by adding reflections to the transmission channels. To minimize the effect ofstubs
termination is placed at the end of the signal path
If your signal transmission line ends on the ni cB-2162, you can use the provided termination
socket. If your signal terminates somewhere other than the ni CB-2162, N recommends
terminating the transmission line at the final signal destination
Note Refer to the help file for your device for more information about proper signal
termination
Terminating Dlo Channel Signals
Table 2 shows the relationship between dio channels and the termination sockets
Table 2. DIo Termination sockets
DIO Channels
Termination socket
DIO<0.7>
J13
DIO<8.15>
J15
DIO<16.23>
J17
DIO<24.31>
J19
Note Refer to the help file for your device for information about the number of
available DIo channels on your device. DIO <20.3 1> may not be applicable to your
device
You can use different resistor networks and jumper placements to terminate the dio channels in
multiple configurations
Figure 7 shows the J13 connector as an example of this termination scheme
Figure 7. Termination Connectivity
J13
TERMINATION
10 ni. com NI CB-2162 User Guide
(系统自动生成,下载前可以参看下载内容)
下载文件列表
相关说明
- 本站资源为会员上传分享交流与学习,如有侵犯您的权益,请联系我们删除.
- 本站是交换下载平台,提供交流渠道,下载内容来自于网络,除下载问题外,其它问题请自行百度。
- 本站已设置防盗链,请勿用迅雷、QQ旋风等多线程下载软件下载资源,下载后用WinRAR最新版进行解压.
- 如果您发现内容无法下载,请稍后再次尝试;或者到消费记录里找到下载记录反馈给我们.
- 下载后发现下载的内容跟说明不相乎,请到消费记录里找到下载记录反馈给我们,经确认后退回积分.
- 如下载前有疑问,可以通过点击"提供者"的名字,查看对方的联系方式,联系对方咨询.